Patient-Specific Compliant Vessel Manufacturing Using Dip-Spin Coating of Rapid Prototyped Molds

被引:20
作者
Arcaute, Karina [1 ]
Wicker, Ryan B. [1 ]
机构
[1] Univ Texas El Paso, Coll Engn, WM Keck Ctr 3D Innovat, El Paso, TX 79968 USA
来源
JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME | 2008年 / 130卷 / 05期
关键词
compliant vessels; anatomical models; cardiovascular system; rapid prototyping; fused deposition modeling; WaterWorks (TM);
D O I
10.1115/1.2898839
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A procedure for manufacturing cardiovascular system models using patient-specific data, rapid prototyping, and a multistep dip-spin coating process is presented here. Improvements to a previously developed process permitted the fabrication of flexible complex vascular replicas. The primary improvement included the development of a two-axis rotation mechanism that enabled a pseudorandom rotation of the coated mold in space, providing uniform coats. Other improvements included the use of a low viscosity (1500-2000 cP) silicone solution that allowed for complete coverage of the mold, and developing a procedure for fixing defects. The dip-spin coating procedure was shown to be effective for the manufacture of compliant cardiovascular membranes, such as an arterial bypass graft with an internal flow passage and an abdominal aorta with nonuniform radial geometry, tapered diameters, bifurcations, and small branches. Results from a design of experiments comparing two dipping setups demostrated that horizontally dipping the model produced coatings with more uniform thicknesses along the length of the model when compared to vertical dipping. For a 250-mm-long model, the difference in thickness between the top and bottom of the membrane was 0.42 +/- 0.069 mm and 0.09 +/- 0.077 mm for vertical and horizontal dippings, respectively. Mold diameter also affected the thickness of the membrane, with membrane thickness increasing as mold diameter decreased. Thickness data comparing locations at approximately the same height of the mold but with different diameters showed thicknesses of 2.54 +/- 0.198 mm and 1.95 +/- 0.140 mm for 7.85 mm and 15.20 mm diameters, respectively. Moreover, the differences in thickness between these locations were 0.60 +/- 0.128 mm and 0.58 +/- 0.231 mm for vertical and horizontal dippings, respectively; thus, membrane thickness variations occurred with mold diameter irrespective of the dipping setup. Depending on the prescribed tolerance for membrane thickness, the vertical dipping setup may be recommended for use because (1) it was easier to use since only the mold was immersed in the coating solution and no special protection of the dipping mechanism was required and (2) it produced fewer defects in the coatings since the solution always dripped from downfacing surfaces of the mold. Using this dip-spin coating procedure, patient-specific cardiovascular membranes can be manufactured and used in the development of medical devices, research requiring accurate anatomical models, and education and training.
引用
收藏
页码:0510081 / 05100813
页数:13
相关论文
共 31 条
  • [1] Multi-step dip-spin coating manufacturing system for silicone cardiovascular membrane fabrication with prescribed compliance
    Cortez, Miguel A.
    Quintana, Rolando
    Wicker, Ryan B.
    [J]. INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2007, 34 (7-8) : 667 - 679
  • [2] A real vessel phantom for flow imaging: 3-D Doppler ultrasound of steady flow
    Dabrowski, W
    Dunmore-Buyze, J
    Cardinal, HN
    Fenster, A
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (01) : 135 - 141
  • [3] Angle-dependent dip-coating technique (ADDC) an improved method for the production of optical filters
    Eberle, A
    Reich, A
    [J]. JOURNAL OF NON-CRYSTALLINE SOLIDS, 1997, 218 : 156 - 162
  • [4] Particle image velocimetry measurements in complex geometries
    Hopkins, LM
    Kelly, JT
    Wexler, AS
    Prasad, AK
    [J]. EXPERIMENTS IN FLUIDS, 2000, 29 (01) : 91 - 95
  • [5] FLOW VISUALIZATION WITH AIR AND SMOKE IN A BYPASS CRAFT MODEL UNDER STEADY FLOW CONDITIONS
    JOHNSON, LR
    SHANEBROOK, JR
    [J]. JOURNAL OF BIOMECHANICS, 1995, 28 (10) : 1237 - 1241
  • [6] Optical filters on linear halogen-lamps prepared by dip-coating
    Kostlin, H
    Frank, G
    Hebbinghaus, G
    Auding, H
    Denissen, K
    [J]. JOURNAL OF NON-CRYSTALLINE SOLIDS, 1997, 218 : 347 - 353
  • [7] Effect of catheter placement on 3-D velocity profiles in curved tubes resembling the human coronary system
    Krams, R
    Wentzel, JJ
    Cespedes, I
    Vinke, R
    Carlier, S
    van der Steen, AFW
    Lancee, CT
    Slager, CJ
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (05) : 803 - 810
  • [8] In vivo validation of numerical prediction of blood flow in arterial bypass grafts
    Ku, JP
    Draney, MT
    Arko, FR
    Lee, WA
    Chan, FP
    Pelc, NJ
    Zarins, CK
    Taylor, CA
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2002, 30 (06) : 743 - 752
  • [9] Aortic aneurysm: Construction of a life-size model by rapid prototyping
    Lermusiaux, P
    Leroux, C
    Tasse, JC
    Castellani, L
    Martinez, R
    [J]. ANNALS OF VASCULAR SURGERY, 2001, 15 (02) : 131 - 135
  • [10] An introduction to biofluid mechanics - basic models and applications
    Liepsch, D
    [J]. JOURNAL OF BIOMECHANICS, 2002, 35 (04) : 415 - 435