Bone and mucosal dosimetry in skin radiation therapy: a Monte Carlo study using kilovoltage photon and megavoltage electron beams

被引:9
作者
Chow, James C. L. [1 ,2 ,3 ]
Jiang, Runqing [4 ,5 ]
机构
[1] Univ Toronto, Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5G 2M9, Canada
[3] Ryerson Univ, Dept Phys, Toronto, ON M5B 2K3, Canada
[4] Grand River Reg Canc Ctr, Dept Med Phys, Kitchener, ON N2G 1G3, Canada
[5] Univ Waterloo, Dept Phys, Waterloo, ON N2L 3G1, Canada
关键词
LATERAL BUILDUP RATIO; EXTERNAL IRRADIATION; DOSE CALCULATION; X-RAYS; COMPLICATION; RADIOTHERAPY; BACKSCATTER; SIMULATION; HEAD;
D O I
10.1088/0031-9155/57/12/3885
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study examines variations of bone and mucosal doses with variable soft tissue and bone thicknesses, mimicking the oral or nasal cavity in skin radiation therapy. Monte Carlo simulations (EGSnrc-based codes) using the clinical kilovoltage (kVp) photon and megavoltage (MeV) electron beams, and the pencil-beam algorithm (Pinnacle(3) treatment planning system) using the MeV electron beams were performed in dose calculations. Phase-space files for the 105 and 220 kVp beams (Gulmay D3225 x-ray machine), and the 4 and 6 MeV electron beams (Varian 21 EX linear accelerator) with a field size of 5 cm diameter were generated using the BEAMnrc code, and verified using measurements. Inhomogeneous phantoms containing uniform water, bone and air layers were irradiated by the kVp photon and MeV electron beams. Relative depth, bone and mucosal doses were calculated for the uniform water and bone layers which were varied in thickness in the ranges of 0.5-2 cm and 0.2-1 cm. A uniform water layer of bolus with thickness equal to the depth of maximum dose (d(max)) of the electron beams (0.7 cm for 4 MeV and 1.5 cm for 6 MeV) was added on top of the phantom to ensure that the maximum dose was at the phantom surface. From our Monte Carlo results, the 4 and 6 MeV electron beams were found to produce insignificant bone and mucosal dose (< 1%), when the uniform water layer at the phantom surface was thicker than 1.5 cm. When considering the 0.5 cm thin uniform water and bone layers, the 4 MeV electron beam deposited less bone and mucosal dose than the 6 MeV beam. Moreover, it was found that the 105 kVp beam produced more than twice the dose to bone than the 220 kVp beam when the uniform water thickness at the phantom surface was small (0.5 cm). However, the difference in bone dose enhancement between the 105 and 220 kVp beams became smaller when the thicknesses of the uniform water and bone layers in the phantom increased. Dose in the second bone layer interfacing with air was found to be higher for the 220 kVp beam than that of the 105 kVp beam, when the bone thickness was 1 cm. In this study, dose deviations of bone and mucosal layers of 18% and 17% were found between our results from Monte Carlo simulation and the pencil-beam algorithm, which overestimated the doses. Relative depth, bone and mucosal doses were studied by varying the beam nature, beam energy and thicknesses of the bone and uniform water using an inhomogeneous phantom to model the oral or nasal cavity. While the dose distribution in the pharynx region is unavailable due to the lack of a commercial treatment planning system commissioned for kVp beam planning in skin radiation therapy, our study provided an essential insight into the radiation staff to justify and estimate bone and mucosal dose.
引用
收藏
页码:3885 / 3899
页数:15
相关论文
共 45 条
[1]  
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[2]   EXTERNAL IRRADIATION OF EPITHELIAL SKIN-CANCER [J].
BRADY, LW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (02) :491-492
[3]   Measurement of dose reductions for superficial x-rays backscattered from bone interfaces [J].
Butson, Martin J. ;
Cheung, Tsang ;
Yu, Peter K. N. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (17) :N329-N336
[4]   Effect of electron beam obliquity on lateral buildup ratio: a Monte Carlo dosimetry evaluation [J].
Chow, James C. L. ;
Grigorov, Grigor N. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (13) :3965-3977
[5]   Calculation of lateral buildup ratio using Monte Carlo simulation for electron radiotherapy [J].
Chow, James C. L. .
MEDICAL PHYSICS, 2007, 34 (01) :175-182
[6]   Dosimetric variation due to the photon beam energy in the small-animal irradiation: A Monte Carlo study [J].
Chow, James C. L. ;
Leung, Michael K. K. ;
Lindsay, Patricia E. ;
Jaffray, David A. .
MEDICAL PHYSICS, 2010, 37 (10) :5322-5329
[7]   Depth dose dependence of the mouse bone using kilovoltage photon beams: A Monte Carlo study for small-animal irradiation [J].
Chow, James C. L. .
RADIATION PHYSICS AND CHEMISTRY, 2010, 79 (05) :567-574
[8]   Cone-beam CT dosimetry for the positional variation in isocenter: A Monte Carlo study [J].
Chow, James C. L. .
MEDICAL PHYSICS, 2009, 36 (08) :3512-3520
[9]   ELECTRON DOSE DISTRIBUTIONS IN EXPERIMENTAL PHANTOMS - A COMPARISON WITH 2D PENCIL BEAM CALCULATIONS [J].
CYGLER, J ;
BATTISTA, JJ ;
SCRIMGER, JW ;
MAH, E ;
ANTOLAK, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (09) :1073-1086
[10]   Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning [J].
Cygler, JE ;
Daskalov, GM ;
Chan, GH ;
Ding, GX .
MEDICAL PHYSICS, 2004, 31 (01) :142-153