Partition efficiencies of an eccentric coiled separation column for centrifugal partition chromatography

被引:4
作者
Ikehata, JI
Shinomiya, K
机构
[1] Nihon Univ, Coll Pharm, Funabashi, Chiba 2748555, Japan
[2] NHLBI, Ctr Biochem & Biophys, NIH, Bethesda, MD 20892 USA
关键词
centrifugal partition chromatography; efficiency; eccentric coiled column;
D O I
10.1080/10826070500225275
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The partition efficiency of an eccentric coiled separation column, newly fabricated in our laboratory, was studied using centrifugal partition chromatography (CPC) with four different two-phase solvent systems including n-hexane-acetonitrile; tert-butyl methyl ether-aqueous 0.1% trifluoroacetic acid (I : 1); 1-butanol-water (I : 1); and 12.5% (w/w) polyethylene glycol 1000-12.5% (w/w) dibasic potassium phosphate. Each separation was performed by eluting either the upper phase in the ascending mode or the lower phase in the descending mode, each in clockwise and counterclockwise (CCW) column rotation. Better partition efficiencies were attained by the CCW rotation in both mobile phases in all the two-phase solvent systems examined. The overall results demonstrated that the coiled separation column yielded substantially higher partition efficiencies than the commercial disk column. The eccentric coiled separation column is useful for the separation by CPC.
引用
收藏
页码:2807 / 2818
页数:12
相关论文
共 9 条
[1]   Effect of Coriolis force on counter-current chromatographic separation by centrifugal partition chromatography [J].
Ikehata, JI ;
Shinomiya, K ;
Kobayashi, K ;
Ohshima, H ;
Kitanaka, S ;
Ito, Y .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1025 (02) :169-175
[2]   Effects of coriolis force on countercurrent chromatography [J].
Ito, Y ;
Ma, Y .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (1-2) :1-17
[3]   Toroidal coil counter-current chromatography study of the mass transfer rate of proteins in aqueous-aqueous polymer phase system [J].
Ito, Y ;
Matsuda, K ;
Ma, Y ;
Qi, L .
JOURNAL OF CHROMATOGRAPHY A, 1998, 802 (02) :277-283
[4]   Toroidal coil counter-current chromatography - Achievement of high resolution by optimizing flow-rate, rotation speed, sample volume and tube length [J].
Matsuda, K ;
Matsuda, S ;
Ito, Y .
JOURNAL OF CHROMATOGRAPHY A, 1998, 808 (1-2) :95-104
[5]   A NEW CENTRIFUGAL COUNTERCURRENT CHROMATOGRAPH AND ITS APPLICATION [J].
MURAYAMA, W ;
KOBAYASHI, T ;
KOSUGE, Y ;
YANO, H ;
NUNOGAKI, Y ;
NUNOGAKI, K .
JOURNAL OF CHROMATOGRAPHY, 1982, 239 (APR) :643-649
[6]   Countercurrent chromatographic separation of hippuric acid and related compounds using cross-axis coil planet centrifuge with eccentric coil assemblies [J].
Shinomiya, K ;
Sasaki, Y ;
Shibusawa, Y ;
Kishinami, K ;
Kabasawa, Y ;
Ito, Y .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (10) :1575-1583
[7]   Countercurrent chromatographic separation of sugars and their p-nitrophenyl derivatives by cross-axis coil planet centrifuge [J].
Shinomiya, K ;
Kabasawa, Y ;
Ito, Y .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1999, 22 (04) :579-592
[8]   Countercurrent chromatographic separation of biotic dicarboxylic acids with polar two-phase solvent systems using cross-axis coil planet centrifuge [J].
Shinomiya, K ;
Kabasawa, Y ;
Ito, Y .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2001, 24 (17) :2625-2634
[9]  
SHINOMIYA K, 1986, BUNSEKI KAGAKU, V35, pT29