Pulmonary Ultrashort Echo Time 19F MR Imaging with Inhaled Fluorinated Gas Mixtures in Healthy Volunteers: Feasibility

被引:55
|
作者
Couch, Marcus J. [1 ,2 ]
Ball, Iain K. [1 ]
Li, Tao [1 ,2 ]
Fox, Matthew S. [1 ]
Littlefield, Shalyn L. [1 ]
Biman, Birubi [3 ,4 ,5 ]
Albert, Mitchell S. [1 ,2 ]
机构
[1] Thunder Bay Reg Res Inst, Thunder Bay, ON P7B 6V4, Canada
[2] Lakehead Univ, Thunder Bay, ON P7B 5E1, Canada
[3] Thunder Bay Reg Hlth Sci Ctr, Thunder Bay, ON, Canada
[4] Northern Ontario Sch Med, Thunder Bay, ON, Canada
[5] McMaster Univ, Dept Med, Hamilton, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
LUNG; VENTILATION; DIFFUSION; SF6; OXYGEN; NMR;
D O I
10.1148/radiol.13130609
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To perform static breath-hold fluorine 19 (F-19) three-dimensional (3D) ultrashort echo time (UTE) magnetic resonance (MR) imaging of the lungs in healthy volunteers by using a mixture of 79% perfluoropropane (PFP) and 21% O-2. Materials and Methods: This study protocol was approved by the local research ethics board and by Health Canada. All volunteers provided written informed consent. Ten healthy volunteers underwent MR imaging at 3.0 T. Fluorine 19 3D UTE MR images were acquired during a 15-second breath hold according to one of two breathing protocols: protocol A, a 1-L inhalation of a mixture of 79% PFP and 21% O-2, and protocol B, continuous breathing from a 5-L bag of a mixture of 79% PFP and 21% O-2 followed by a 1-L inhalation of the same PFP-O-2 mixture from a separate bag and a subsequent breath hold. The signal-to-noise ratio (SNR) was measured in the three most central image sections and was compared between breathing protocols by using an unpaired t test. Results: Overall, the SNR was significantly greater for breathing protocol B (continuous breathing) than for breathing protocol A (single breath) (P = .018). The mean SNRs were 18 +/- 6 (standard deviation) and 32 +/- 6 for images acquired by using breathing protocols A and B, respectively. Breathing protocol B improves SNR by "washing out" the air from the lungs and increasing the PFP concentration prior to F-19 imaging. Conclusion: This study demonstrates the feasibility of F-19 3D UTE static breath-hold MR imaging of human lungs with inert fluorinated gases. (C) RSNA, 2013
引用
收藏
页码:903 / 909
页数:7
相关论文
共 4 条
  • [1] Volume-Controlled 19F MR Ventilation Imaging of Fluorinated Gas
    Obert, Arnd J.
    Kern, Agilo L.
    Gutberlet, Marcel
    Voskrebenzev, Andreas
    Kaireit, Till F.
    Crisosto, Cristian
    Greer, Mark
    Krause, E. Tobias
    Wacker, Frank
    Vogel-Claussen, Jens
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (04) : 1114 - 1128
  • [2] Reproducibility of 19F-MR ventilation imaging in healthy volunteers
    Pippard, Benjamin J.
    Neal, Mary A.
    Maunder, Adam M.
    Hollingsworth, Kieren G.
    Biancardi, Alberto
    Lawson, Rod A.
    Fisher, Holly
    Matthews, John N. S.
    Simpson, A. John
    Wild, Jim M.
    Thelwall, Peter E.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (06) : 3343 - 3352
  • [3] Repeatability of Regional Lung Ventilation Quantification Using Fluorinated (19F) Gas Magnetic Resonance Imaging
    Gutberlet, Marcel
    Kaireit, Till F.
    Voskrebenzev, Andreas
    Kern, Agilo L.
    Obert, Arnd
    Wacker, Frank
    Hohlfeld, Jens M.
    Vogel-Claussen, Jens
    ACADEMIC RADIOLOGY, 2019, 26 (03) : 395 - 403
  • [4] MR properties of19F C3F8gas in the lungs of healthy volunteers:T2*and apparent diffusion coefficient at 1.5T andT2*at 3T
    Maunder, Adam
    Chan, Ho-Fung
    Hughes, Paul J. C.
    Collier, Guillhem
    Norquay, Graham
    Rodgers, Oliver
    Thelwall, Peter
    Robb, Fraser
    Rao, Madhwesha
    Wild, Jim M.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (03) : 1561 - 1570