ASSESSMENT OF CONDENSATION HEAT TRANSFER MODEL TO EVALUATE PERFORMANCE OF THE PASSIVE AUXILIARY FEEDWATER SYSTEM

被引:22
作者
Cho, Yun-Je [1 ]
Kim, Seok [1 ]
Bae, Byoung-Uhn [1 ]
Park, Yusun [1 ]
Kang, Kyoung-Ho [1 ]
Yun, Byong-Jo [1 ]
机构
[1] Korea Atom Energy Res Inst, Thermal Hydraul Safety Res Dept, Taejon 305353, South Korea
关键词
Passive Safety System; PAFS; Condensation Heat Transfer; MARS;
D O I
10.5516/NET.02.2013.523
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
As passive safety features for nuclear power plants receive increasing attention, various studies have been conducted to develop safety systems for 3rd-generation (GEN-III) nuclear power plants that are driven by passive systems. The Passive Auxiliary Feedwater System (PAFS) is one of several passive safety systems being designed for the Advanced Power Reactor Plus (APR+), and extensive studies are being conducted to complete its design and to verify its feasibility. Because the PAFS removes decay heat from the reactor core under transient and accident conditions, it is necessary to evaluate the heat removal capability of the PAFS under hypothetical accident conditions. The heat removal capability of the PAFS is strongly dependent on the heat transfer at the condensate tube in Passive Condensation Heat Exchanger (PCHX). To evaluate the model of heat transfer coefficient for condensation, the Multi-dimensional Analysis of Reactor Safety (MARS) code is used to simulate the experimental results from PAFS Condensing Heat Removal Assessment Loop (PASCAL). The Shah model, a default model for condensation heat transfer coefficient in the MARS code, under-predicts the experimental data from the PASCAL. To improve the calculation result, The Thome model and the new version of the Shah model are implemented and compared with the experimental data.
引用
收藏
页码:759 / 766
页数:8
相关论文
共 10 条
  • [1] Bae B. U., 2010, 7 KOR JAP S NUCL THE
  • [2] An explicit approximation for the wetted angle in two-phase stratified pipe flow
    Biberg, D
    [J]. CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1999, 77 (06) : 1221 - 1224
  • [3] Cho Y. J., 2012, 8 KSME JSME THERM FL
  • [4] SEPARATE AND INTEGRAL EFFECT TESTS FOR VALIDATION OF COOLING AND OPERATIONAL PERFORMANCE OF THE APR plus PASSIVE AUXILIARY FEEDWATER SYSTEM
    Kang, Kyoung-Ho
    Kim, Seok
    Bae, Byoung-Uhn
    Cho, Yun-Je
    Park, Yu-Sun
    Yun, Byong-Jo
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2012, 44 (06) : 597 - 610
  • [5] RELAP5/Mod3 Code Manual, 1995, NUREGCR 5535 INEL 95, VIV
  • [6] An Improved and Extended General Correlation for Heat Transfer During Condensation in Plain Tubes
    Shah, M. Mohammed
    [J]. HVAC&R RESEARCH, 2009, 15 (05): : 889 - 913
  • [7] Song C. H., 2010, 18 INT C NUCL ENG XI
  • [8] Thom J. R., 2003, J HEAT MASS TRANSFER, V46, P3365
  • [9] Thom J. R., 2003, J HEAT MASS TRANSFER, V46, P3349
  • [10] Yun B.J, 2010, KAERI-TR-4085-2010