Precision and accuracy of robot-assisted technology with simplified express femoral workflow in measuring leg length and offset in total hip arthroplasty

被引:13
作者
Cozzi Lepri, Andrea [1 ,2 ]
Villano, Marco [1 ,2 ]
Innocenti, Matteo [1 ,2 ]
Porciatti, Tommaso [1 ,2 ]
Matassi, Fabrizio [1 ,2 ]
Civinini, Roberto [1 ,2 ]
机构
[1] Univ Florence, Dept Hlth Sci, Orthped Unit, Florence, Italy
[2] CTO, Florence, Italy
关键词
combined offset; express femoral workflow; leg length discrepancy; robot-assisted technology; total hip arthroplasty; DISCREPANCY; PLACEMENT;
D O I
10.1002/rcs.2141
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Semi-active robot-assisted total hip arthroplasty (THA) has two options to measure the leg length discrepancy (LLD) and combined offset (CO), the 'enhanced' femoral workflow and the so-called 'express' simplified workflow. The purpose of this study was to determine the precision and accuracy of intraoperative LLD and CO measurement with express workflow robotic THA. Methods Between February 2018 and December 2019, 30 patients underwent an express workflow robot-assisted primary THA for intraoperative LLD and CO measurements. Postoperative radiographs were used for LLD and CO measurement. In order to examine the accuracy of the robotic system assessment, the absolute difference between the robotic assessments and radiographic evaluations was calculated. Results Intraoperative robotic measurements reported a mean error of 0.2-0.6 mm for each registration, with no significant difference between them (p= 0.311). The average absolute discrepancies between the robotic and radiographic assessments in the LLD and CO measurements were 1.3 +/- 1.5 mm (p= 0.17) and 1.1 +/- 0.9 mm (p= 0.11), respectively, while the Pearson's correlation coefficients were 0.69 and 0.71. Conclusions An external marker without a femoral array inserted into a screw positioned in the greater trochanter would be an easier and faster method to measure LLD and CO. Our study showed that the measured values of LLD and CO obtained by intraoperative express workflow robot-assisted THA system were precise and accurate.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 23 条
[1]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[2]   The anterior-based muscle-sparing approach to the hip: the "other" anterior approach to the hip [J].
Civinini, Roberto ;
Lepri, Andrea Cozzi ;
Carulli, Christian ;
Matassi, Fabrizio ;
Villano, Marco ;
Innocenti, Massimo .
INTERNATIONAL ORTHOPAEDICS, 2019, 43 (01) :47-53
[3]   Hip Offset in Total Hip Arthroplasty Quantitative Measurement with Navigation [J].
Dastane, Manish ;
Dorr, Lawrence D. ;
Tarwala, Rupesh ;
Wan, Zhinian .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) :429-436
[4]   Accuracy of Component Positioning in 1980 Total Hip Arthroplasties: A Comparative Analysis by Surgical Technique and Mode of Guidance [J].
Domb, Benjamin G. ;
Redmond, John M. ;
Louis, Steven S. ;
Alden, Kris J. ;
Daley, Robert J. ;
LaReau, Justin M. ;
Petrakos, Alexandra E. ;
Gui, Chengcheng ;
Suarez-Ahedo, Carlos .
JOURNAL OF ARTHROPLASTY, 2015, 30 (12) :2208-2218
[5]   Comparison of Robotic-assisted and Conventional Acetabular Cup Placement in THA: A Matched-pair Controlled Study [J].
Domb, Benjamin G. ;
El Bitar, Youssef F. ;
Sadik, Adam Y. ;
Stake, Christine E. ;
Botser, Itamar B. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (01) :329-336
[6]   Leg length discrepancy in computer navigated total hip arthroplasty - how accurate are we? [J].
Ellapparadja, Pregash ;
Mahajan, Vivek ;
Atiya, Sami ;
Sankar, Biju ;
Deep, Kamal .
HIP INTERNATIONAL, 2016, 26 (05) :438-443
[7]   INTRODUCTION TO BIOSTATISTICS .6. CORRELATION AND REGRESSION [J].
GADDIS, ML ;
GADDIS, GM .
ANNALS OF EMERGENCY MEDICINE, 1990, 19 (12) :1462-1468
[8]   Robotics in Arthroplasty: A Comprehensive Review [J].
Jacofsky, David J. ;
Allen, Mark .
JOURNAL OF ARTHROPLASTY, 2016, 31 (10) :2353-2363
[9]   Adoption of Robotic vs Fluoroscopic Guidance in Total Hip Arthroplasty: Is Acetabular Positioning Improved in the Learning Curve? [J].
Kamara, Eli ;
Robinson, Jonathon ;
Bas, Marcel A. ;
Rodriguez, Jose A. ;
Hepinstall, Matthew S. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (01) :125-130
[10]   The current role of robotics in total hip arthroplasty [J].
Kayani, Babar ;
Konan, Sujith ;
Ayuob, Atif ;
Ayyad, Salamah ;
Haddad, Fares S. .
EFORT OPEN REVIEWS, 2019, 4 (11) :618-625