Comparative evaluation of 14 immunoassays for detection of antibodies to the human T-lymphotropic virus types I and II using panels of sera from Sweden and West Africa

被引:24
作者
Andersson, S
Thorstensson, R
Ramirez, KG
Krook, A
von Sydow, M
Dias, F
Biberfeld, G
机构
[1] Swedish Inst Infect Dis Control, Dept Immunol, S-17182 Solna, Sweden
[2] Karolinska Inst, Ctr Microbiol & Tumor Biol, Stockholm, Sweden
[3] Karolinska Hosp, Huddinge Univ Hosp, Dept Clin Microbiol, S-10401 Stockholm, Sweden
[4] Karolinska Hosp, Huddinge Univ Hosp, Dept Infect Dis, S-10401 Stockholm, Sweden
[5] Natl Publ Hlth Lab, Bissau, Guinea Bissau
关键词
D O I
10.1046/j.1537-2995.1999.39080845.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: A new generation of assays for the detection of human T-lymphotropic virus types I and II (HTLV-I/II) antibodies has been released. These assays incorporate HTLV-I- and HTLV-II-specific antigens, and some are based on new assay principles. Comparative evaluation data that include these new as well as previous assays are limited. STUDY DESIGN AND METHODS: Fourteen HTLV antibody assays were evaluated by using well-characterized panels of sera from Guinea-Bissau, West Africa, and Sweden. The sera included 127 HTLV-I-positive and 62 HTLV-II-positive specimens, as well as 919 consecutive negative samples. RESULTS: The sensitivity for HTLV-I was 100 percent for all assays, except one, which repeatedly missed one sample. The sensitivity for HTLV-II varied between 86 percent and 100 percent. In general, new-generation assays incorporating HTLV-II-specific antigens, and some of which are based on new assay principles, had a higher sensitivity for HTLV-II than previous assays, which mainly are based on HTLV-I antigens. The specificity was generally higher for new assays than for the previous versions. Testing of Swedish blood donor sera gave higher specificities (94-1.00%) than did that of African specimens (90-99.7%). Most assays had low delta values (DVs), although there was a tendency toward increased DVs for the new generation of assays. Only two of the new generation of assays came close to a combination of high sensitivity for both HTLV-I and HTLV-II, high specificity, positive and negative predictive values, and high DVs. CONCLUSION: The sensitivity for HTLV-I was generally high and appears to have improved for HTLV-II with the introduction of a new generation of assays incorporating HTLV-II-specific antigens. However, some assays still give false-negative results on HTLV-II-positive specimens. The specificities and the DVs were generally higher for the new assays than for the previous versions.
引用
收藏
页码:845 / 851
页数:7
相关论文
共 23 条
[11]   EVALUATION OF ENZYME IMMUNOASSAYS FOR ANTIBODY TO HUMAN T-LYMPHOTROPIC VIRUSES TYPE-I/II [J].
KLINE, RL ;
BROTHERS, T ;
HALSEY, N ;
BOULOS, R ;
LAIRMORE, MD ;
QUINN, TC .
LANCET, 1991, 337 (8732) :30-33
[12]   Prevalence and risk factors for HTLV-II infection in 913 injecting drug users in Stockholm, 1994 [J].
Krook, A ;
Albert, J ;
Andersson, S ;
Biberfeld, G ;
Blomberg, J ;
Eklund, I ;
Engstrom, A ;
Julander, I ;
Kall, K ;
Martin, C ;
Stendahl, P ;
Struve, J ;
Sonnerborg, A .
JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 1997, 15 (05) :381-386
[13]   HTLV-II-RELATED DISEASE [J].
MURPHY, EL .
LANCET, 1993, 341 (8849) :888-888
[14]   TRANSMISSION OF HUMAN T-CELL LYMPHOTROPIC VIRUS (HTLV) TYPE-II BY TRANSFUSION OF HTLV-I-SCREENED BLOOD PRODUCTS [J].
RIOS, M ;
KHABBAZ, RF ;
KAPLAN, JE ;
HALL, WW ;
KESSLER, D ;
BIANCO, C .
JOURNAL OF INFECTIOUS DISEASES, 1994, 170 (01) :206-210
[15]   MISDIAGNOSIS OF HTLV-II INFECTION USING HTLV-I SCREENING ASSAYS [J].
SORIANO, V ;
CALDERON, E ;
GUTIERREZ, M ;
TUSET, C ;
MARTINEZZAPICO, R ;
GONZALEZLAHOZ, J .
AIDS, 1993, 7 (10) :1395-1395
[16]   Screening for human T cell leukaemia/lymphoma virus among blood donors in Sweden: cost effectiveness analysis [J].
Tynell, E ;
Andersson, S ;
Lithander, E ;
Arneborn, M ;
Blomberg, J ;
Hansson, HB ;
Krook, A ;
Nomberg, M ;
Ramstedt, K ;
Shanwell, A ;
Bjorkman, A .
BRITISH MEDICAL JOURNAL, 1998, 316 (7142) :1417-1422
[17]   Sensitivity and specificity of four assays to detect human T-lymphotropic virus type I or type I/II antibodies [J].
Vrielink, H ;
Reesink, HW ;
Zaaijer, HL ;
vanderPoel, CL ;
Cuypers, HTM ;
Lelie, PN .
TRANSFUSION, 1996, 36 (04) :344-346
[18]  
WEISS SH, 1994, AIDS RES HUM RETROV, V10, P451
[19]  
*WHO GLOB PROGR AI, 1991, 3 WHO GLOB PROGR AID
[20]   SENSITIVITY OF HTLV-I ANTIBODY-ASSAYS FOR HTLV-II [J].
WIKTOR, SZ ;
PATE, EJ ;
WEISS, SH ;
GOHD, RS ;
CORREA, P ;
FONTHAM, ET ;
HANCHARD, B ;
BIGGAR, RJ ;
BLATTNER, WA .
LANCET, 1991, 338 (8765) :512-513