Peri-prosthetic femoral fractures treated with the uncemented Wagner revision stem

被引:11
作者
Marx, Axel [1 ]
Beier, Alexander [1 ]
Jung, Laura [1 ]
Lohmann, Christoph H. [2 ]
Halder, Andreas M. [1 ]
机构
[1] Sana Kliniken Sommerfeld, Clin Joint Replacement, D-16766 Sommerfeld, Germany
[2] Univ Magdeburg, Dept Orthopaed Surg, D-39106 Magdeburg, Germany
关键词
Wagner revision stem; Peri-prosthetic fracture; Vancouver classification; Revision arthroplasty; TOTAL HIP-ARTHROPLASTY; PERIPROSTHETIC FEMUR FRACTURE; EPIDEMIOLOGY; MANAGEMENT;
D O I
10.5301/HIP.2012.9246
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The clinical and radiological results of Vancouver type B2 and B3 peri-prosthetic fractures treated with an uncemented Wagner revision stem (3rd generation) were analysed. Two groups were identified, 15 patients had a B2 and 14 cases a B3 periprosthetic fracture. The mean follow-up was 74 months after the index operation. All fractures had united radiographically. No cases of non-union were found. There was only one case of aseptic loosening. The clinical scores presented encouraging results for both groups. The uncemented distal fixation stem was an effective solution in the treatment of type B2 and B3 periprosthetic femur fractures at mid-term follow up.
引用
收藏
页码:286 / 291
页数:6
相关论文
共 50 条
  • [11] Femoral revision with the Wagner tapered stem
    Regis, D.
    Sandri, A.
    Bonetti, I.
    Braggion, M.
    Bartolozzi, P.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (10): : 1320 - 1326
  • [12] A rare case of a bisphosphonate-induced peri-prosthetic femoral fracture
    Cross, M. B.
    Nam, D.
    van der Meulen, M. C. H.
    Bostrom, M. P. G.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (07): : 994 - 997
  • [13] Short uncemented stems allow greater femoral flexibility and may reduce peri-prosthetic fracture risk: a dry bone and cadaveric study
    Jones C.
    Aqil A.
    Clarke S.
    Cobb J.P.
    Journal of Orthopaedics and Traumatology, 2015, 16 (3) : 229 - 235
  • [14] Small interprosthetic gaps do not increase femoral peri-prosthetic fracture risk. An in vitro biomechanical analysis
    Quirynen, Thomas
    Corten, Kristoff
    Segal, Olivier
    Simon, Jean-Pierre
    Vander Sloten, Jos
    van Lenthe, Harry G.
    ACTA ORTHOPAEDICA BELGICA, 2017, 83 (02): : 197 - 204
  • [15] Revision arthroplasty for periprosthetic femoral fracture using an uncemented modular tapered conical stem
    da Assuncao, R. E.
    Pollard, T. C. B.
    Hrycaiczuk, A.
    Curry, J.
    Glyn-Jones, S.
    Taylor, A.
    BONE & JOINT JOURNAL, 2015, 97B (08) : 1031 - 1037
  • [16] Single-stage revision for peri-prosthetic shoulder infection OUTCOMES AND RESULTS
    Klatte, T. O.
    Junghans, K.
    Al-Khateeb, H.
    Rueger, J. M.
    Gehrke, T.
    Kendoff, D.
    Neumann, J.
    BONE & JOINT JOURNAL, 2013, 95B (03) : 391 - 395
  • [17] Operative Treatment of Early Peri-Prosthetic Femur Fractures Following Primary Total Hip Arthroplasty
    Sheth, Neil P.
    Brown, Nicholas M.
    Moric, Mario
    Berger, Richard A.
    Della Valle, Craig J.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (02) : 286 - 291
  • [18] Peri-prosthetic fractures around tumor endoprostheses: a retrospective analysis of eighteen cases
    Barut, Nicolas
    Anract, Philippe
    Babinet, Antoine
    Biau, David
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (09) : 1851 - 1856
  • [19] Peri-prosthetic fractures around tumor endoprostheses: a retrospective analysis of eighteen cases
    Nicolas Barut
    Philippe Anract
    Antoine Babinet
    David Biau
    International Orthopaedics, 2015, 39 : 1851 - 1856
  • [20] The uncemented diaphysal fixation of femoral revision stems in case of large bone defects -: Analysis of twelve years experience with the Wagner SL revision stem
    Böhm, P
    Bischel, O
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2001, 139 (03): : 229 - 239