Peri-prosthetic femoral fractures treated with the uncemented Wagner revision stem

被引:11
|
作者
Marx, Axel [1 ]
Beier, Alexander [1 ]
Jung, Laura [1 ]
Lohmann, Christoph H. [2 ]
Halder, Andreas M. [1 ]
机构
[1] Sana Kliniken Sommerfeld, Clin Joint Replacement, D-16766 Sommerfeld, Germany
[2] Univ Magdeburg, Dept Orthopaed Surg, D-39106 Magdeburg, Germany
关键词
Wagner revision stem; Peri-prosthetic fracture; Vancouver classification; Revision arthroplasty; TOTAL HIP-ARTHROPLASTY; PERIPROSTHETIC FEMUR FRACTURE; EPIDEMIOLOGY; MANAGEMENT;
D O I
10.5301/HIP.2012.9246
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The clinical and radiological results of Vancouver type B2 and B3 peri-prosthetic fractures treated with an uncemented Wagner revision stem (3rd generation) were analysed. Two groups were identified, 15 patients had a B2 and 14 cases a B3 periprosthetic fracture. The mean follow-up was 74 months after the index operation. All fractures had united radiographically. No cases of non-union were found. There was only one case of aseptic loosening. The clinical scores presented encouraging results for both groups. The uncemented distal fixation stem was an effective solution in the treatment of type B2 and B3 periprosthetic femur fractures at mid-term follow up.
引用
收藏
页码:286 / 291
页数:6
相关论文
共 50 条
  • [1] Distal locking stem for revision femoral loosening and peri-prosthetic fractures
    Mertl, Patrice
    Philippot, Remy
    Rosset, Philippe
    Migaud, Henri
    Tabutin, Jacques
    Van de Velde, Denis
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (02) : 275 - 282
  • [2] Distal locking stem for revision femoral loosening and peri-prosthetic fractures
    Patrice Mertl
    Remy Philippot
    Philippe Rosset
    Henri Migaud
    Jacques Tabutin
    Denis Van de Velde
    International Orthopaedics, 2011, 35 : 275 - 282
  • [3] Peri-prosthetic femoral shaft fractures treated with plate and cable fixation
    Kamineni, S
    Vindlacheruvu, R
    Ware, HE
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1999, 30 (04): : 261 - 268
  • [4] The Mennen plate: unsuitable for elderly femoral peri-prosthetic fractures
    Kamineni, S
    Ware, HE
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1999, 30 (04): : 257 - 260
  • [5] Has a patient type with peri-prosthetic femoral fractures evolved?
    Ehlinger, Matthieu
    Bahlau, David
    Rahme, Michel
    Adam, Philippe
    Bonnomet, Francois
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (09) : 1833 - 1838
  • [6] Has a patient type with peri-prosthetic femoral fractures evolved?
    Matthieu Ehlinger
    David Bahlau
    Michel Rahme
    Philippe Adam
    François Bonnomet
    International Orthopaedics, 2015, 39 : 1833 - 1838
  • [7] European validation of the Vancouver classification of peri-prosthetic proximal femoral fractures
    Rayan, F.
    Dodd, M.
    Haddad, F. S.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (12): : 1576 - 1579
  • [8] Peri-prosthetic fractures: A problem on the rise
    Hozack, WJ
    ORTHOPEDICS, 2005, 28 (09) : 961 - 961
  • [9] Late peri-prosthetic femoral fracture as a major mode of failure in uncemented primary hip replacement
    Streit, M. R.
    Merle, C.
    Clarius, M.
    Aldinger, P. R.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (02): : 178 - 183
  • [10] An improved cementing technique for revision hip surgery after peri-prosthetic fractures
    Sandhu, SS
    Fern, ED
    Parsons, SW
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1999, 30 (03): : 195 - 198