T-one insensitive steady state imaging: A framework for purely T2-weighted TrueFISP

被引:4
作者
Schmitt, Peter [1 ]
Jakob, Peter M. [2 ]
Kotas, Markus [3 ]
Flentje, Michael [4 ]
Haase, Axel [5 ]
Griswold, Mark A. [6 ]
机构
[1] Siemens AG, Healthcare Sect, MR Applicat & Workflow Dev, Erlangen, Germany
[2] Univ Wurzburg, Inst Phys, Dept Expt Phys 5, D-8700 Wurzburg, Germany
[3] Univ Wurzburg, Dept Patient Management & Med Controlling, Wurzburg, Germany
[4] Univ Wurzburg, Dept Radiat Oncol, Wurzburg, Germany
[5] Tech Univ Munich, Inst Adv Study, Munich, Germany
[6] Univ Hosp Cleveland, Dept Radiol, Cleveland, OH 44106 USA
关键词
T-one insensitive steady state imaging; fast T2-weighted imaging; steady state free precession; True free induction steady precession; SSFP SEQUENCES; MAGNETIC-RESONANCE; TRANSIENT-RESPONSE; FLIP ANGLES; CONTRAST; FISP; NMR; T-2; SPECTROSCOPY; DIFFUSION;
D O I
10.1002/mrm.23239
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new conceptual framework called T-one insensitive steady state imaging is proposed for fast generation of MR images with pure T2 contrast. This is accomplished by imaging between nonequally spaced inversion pulses, with the magnetization vector alternatively residing in states parallel and antiparallel to B0 for durations TPi and TAi, respectively. With TPi and TAi adequately chosen, identical signal time evolution can be obtained for different T1 values, i.e., T1 contrast can efficiently be removed from resultant images. As a specific realization of this principle, T-one insensitive steady state imaging sequences are presented which use True free induction steady precession readout blocks between the inversion pulses. While the conventional True free induction steady precession signal time course would be determined by both T2 and T1, a pure T2 dependence is realized with successfully suppressed influence of longitudinal relaxation, and images with essentially T2 contrast alone are obtained. Analytical expressions are provided for the description of the ideal signal behavior, which help in creating pathways for sequence parameter optimization. The performance of the technique is analyzed with Bloch equation simulations. In vivo results obtained in healthy volunteers and brain tumor patients are presented. Magn Reson Med, 2012. (C) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:409 / 420
页数:12
相关论文
共 39 条
  • [1] On the origin of apparent low tissue signals in balanced SSFD
    Bieri, O.
    Scheffler, K.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (05) : 1067 - 1074
  • [2] Bieri O, 2010, P 18 ANN M ISMRM STO, P73
  • [3] SSFP Signal With Finite RF Pulses
    Bieri, Oliver
    Scheffler, Klaus
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (05) : 1232 - 1241
  • [4] CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST
    BRITTAIN, JH
    HU, BS
    WRIGHT, GA
    MEYER, CH
    MACOVSKI, A
    NISHIMURA, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) : 689 - 696
  • [5] T2-weighted fast MR imaging with true FISP versus HASTE: Comparative efficacy in the evaluation of normal fetal brain maturation
    Chung, HW
    Chen, CY
    Zimmerman, RA
    Lee, KW
    Lee, CC
    Chin, SC
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (05) : 1375 - 1380
  • [6] MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results
    de Bazelaire, CMJ
    Duhamel, GD
    Rofsky, NM
    Alsop, DC
    [J]. RADIOLOGY, 2004, 230 (03) : 652 - 659
  • [7] Deimling M., 1994, PROC 2 ANN M SMR SAN, P495
  • [8] Derakhshan JJ, 2006, P 14 ANN M ISMRM SEA, P2427
  • [9] Derakhshan JJ, 2007, P 15 SCI M ISMRM, P585
  • [10] Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2 T
    Duerk, JL
    Lewin, JS
    Wendt, M
    Petersilge, C
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01): : 203 - 208