Cross-sectional area measurement of soft tissue. A new casting method

被引:35
作者
Race, A
Amis, AA
机构
[1] Mechanical Engineering Department, Imp. Coll. of Sci. Technol./Medicine, London SWX, Exhibition Road
关键词
collagenous tissues; biomechanics; ligament morphology; area measurements;
D O I
10.1016/0021-9290(96)00022-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new replica moulding technique for determining cross-sectional area has been developed. The accuracy of this technique has been investigated. Comparisons have been made with the area micrometer and the laser micrometer to establish the relative accuracy of each technique. The replica technique systematically underestimated the cross-sectional area by 6.2%. However, when this shrinkage artefact was corrected for, the residual error was +/-1.8%. Relative to the corrected replica method, it was calculated that the area micrometer underestimated cross-sectional area by 16.2+/-6.9% (SD) and that the assumption of a convex cross-section would have caused the laser micrometer to overestimate cross-sectional area by an average of 2.3+/-1.5% (SD) for tendon, 4.7+/-2.5% for 'round' ligament specimens and 19.1+/-6.4% for cruciate ligament bundles with obvious concavities in their cross-sections. The moulding method was thought to be particularly useful for soft tissue specimens with irregular cross-sections. Copyright (C) 1996 Elsevier Science Ltd.
引用
收藏
页码:1207 / 1212
页数:6
相关论文
共 9 条
[1]   COMPARISON OF MATERIAL PROPERTIES IN FASCICLE-BONE UNITS FROM HUMAN PATELLAR TENDON AND KNEE LIGAMENTS [J].
BUTLER, DL ;
KAY, MD ;
STOUFFER, DC .
JOURNAL OF BIOMECHANICS, 1986, 19 (06) :425-432
[2]  
CHAN KH, 1991, JOINT REPLACEMENT AR, P23
[3]  
DANTO MI, 1989, AMD ASME, V98, P97
[4]   CROSS-SECTIONAL AREA MEASUREMENTS FOR TENDON SPECIMENS - A COMPARISON OF SEVERAL METHODS [J].
ELLIS, DG .
JOURNAL OF BIOMECHANICS, 1969, 2 (02) :175-&
[5]   COMPARATIVE-STUDY OF THE SIZE AND SHAPE OF HUMAN ANTERIOR AND POSTERIOR CRUCIATE LIGAMENTS [J].
HARNER, CD ;
LIVESAY, GA ;
KASHIWAGUCHI, S ;
FUJIE, H ;
CHOI, NY ;
WOO, SLY .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (03) :429-434
[6]   A NEW METHOD FOR DETERMINING CROSS-SECTIONAL SHAPE AND AREA OF SOFT-TISSUES [J].
LEE, TQ ;
WOO, SLY .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1988, 110 (02) :110-114
[7]   THE MECHANICAL-PROPERTIES OF THE 2 BUNDLES OF THE HUMAN POSTERIOR CRUCIATE LIGAMENT [J].
RACE, A ;
AMIS, AA .
JOURNAL OF BIOMECHANICS, 1994, 27 (01) :13-24
[8]   MEASUREMENT OF THE SURFACE MICROGEOMETRY OF ARTICULAR-CARTILAGE [J].
SAYLES, RS ;
THOMAS, TR ;
ANDERSON, J ;
HASLOCK, I ;
UNSWORTH, A .
JOURNAL OF BIOMECHANICS, 1979, 12 (04) :257-267
[9]   THE USE OF A LASER MICROMETER SYSTEM TO DETERMINE THE CROSS-SECTIONAL SHAPE AND AREA OF LIGAMENTS - A COMPARATIVE-STUDY WITH 2 EXISTING METHODS [J].
WOO, SLY ;
DANTO, MI ;
OHLAND, KJ ;
LEE, TQ ;
NEWTON, PO .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (04) :426-431