Scanning Ion Conductance Microscopy for Studying Biological Samples

被引:57
作者
Happel, Patrick [1 ]
Thatenhorst, Denis [2 ]
Dietzel, Irmgard D. [2 ]
机构
[1] Ruhr Univ Bochum, Cent Unit Ionbeams & Radionuclides RUBION, D-44780 Bochum, Germany
[2] Ruhr Univ Bochum, Dept Mol Neurobiochem, D-44780 Bochum, Germany
来源
SENSORS | 2012年 / 12卷 / 11期
关键词
scanning ion conductance microscopy; live cell imaging; ion selective micro-electrodes; ATOMIC-FORCE MICROSCOPY; SURFACE CONFOCAL MICROSCOPY; DEPLETION FLUORESCENCE MICROSCOPY; ELECTROCHEMICAL-CELL MICROSCOPY; DIFFRACTION RESOLUTION LIMIT; STIMULUS-INDUCED CHANGES; LIVING CELLS; HEART-FAILURE; CONTROLLED DEPOSITION; EXTRACELLULAR-SPACE;
D O I
10.3390/s121114983
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Scanning ion conductance microscopy (SICM) is a scanning probe technique that utilizes the increase in access resistance that occurs if an electrolyte filled glass micro-pipette is approached towards a poorly conducting surface. Since an increase in resistance can be monitored before the physical contact between scanning probe tip and sample, this technique is particularly useful to investigate the topography of delicate samples such as living cells. SICM has shown its potential in various applications such as high resolution and long-time imaging of living cells or the determination of local changes in cellular volume. Furthermore, SICM has been combined with various techniques such as fluorescence microscopy or patch clamping to reveal localized information about proteins or protein functions. This review details the various advantages and pitfalls of SICM and provides an overview of the recent developments and applications of SICM in biological imaging. Furthermore, we show that in principle, a combination of SICM and ion selective micro-electrodes enables one to monitor the local ion activity surrounding a living cell.
引用
收藏
页码:14983 / 15008
页数:26
相关论文
共 112 条
  • [1] Abbe E., 1873, Archiv f ur Mikroskopische Anatomie, V9, P413, DOI DOI 10.1007/BF02956173
  • [2] Atomic force microscopy of biological samples
    Allison, David P.
    Mortensen, Ninell P.
    Sullivan, Claretta J.
    Doktycz, Mitchel J.
    [J]. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY, 2010, 2 (06) : 618 - 634
  • [3] BIOPHYSICAL APPLICATIONS OF SCANNING ION CONDUCTANCE MICROSCOPY (SICM)
    Anariba, Franklin
    Anh, Joon Hyung
    Jung, Goo-Eun
    Cho, Nam-Joon
    Cho, Sang-Joon
    [J]. MODERN PHYSICS LETTERS B, 2012, 26 (05):
  • [4] SCANNING ELECTROCHEMICAL MICROSCOPY - INTRODUCTION AND PRINCIPLES
    BARD, AJ
    FAN, FRF
    KWAK, J
    LEV, O
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (02) : 132 - 138
  • [5] Imaging intracellular fluorescent proteins at nanometer resolution
    Betzig, Eric
    Patterson, George H.
    Sougrat, Rachid
    Lindwasser, O. Wolf
    Olenych, Scott
    Bonifacino, Juan S.
    Davidson, Michael W.
    Lippincott-Schwartz, Jennifer
    Hess, Harald F.
    [J]. SCIENCE, 2006, 313 (5793) : 1642 - 1645
  • [6] ATOMIC FORCE MICROSCOPE
    BINNIG, G
    QUATE, CF
    GERBER, C
    [J]. PHYSICAL REVIEW LETTERS, 1986, 56 (09) : 930 - 933
  • [7] SURFACE STUDIES BY SCANNING TUNNELING MICROSCOPY
    BINNING, G
    ROHRER, H
    GERBER, C
    WEIBEL, E
    [J]. PHYSICAL REVIEW LETTERS, 1982, 49 (01) : 57 - 61
  • [8] Imaging and Patterning of Pore-Suspending Membranes with Scanning Ion Conductance Microscopy
    Boecker, Matthias
    Muschter, Steffen
    Schmitt, Eva K.
    Steinem, Claudia
    Schaeffer, Tilman E.
    [J]. LANGMUIR, 2009, 25 (05) : 3022 - 3028
  • [9] An addressable antibody nanoarray produced on a nanostructured surface
    Bruckbauer, A
    Zhou, DJ
    Kang, DJ
    Korchev, YE
    Abell, C
    Klenerman, D
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (21) : 6508 - 6509
  • [10] Multicomponent submicron features of biomolecules created by voltage controlled deposition from a nanopipet
    Bruckbauer, A
    Zhou, DJ
    Ying, LM
    Korchev, YE
    Abell, C
    Klenerman, D
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (32) : 9834 - 9839