Assessment of water quality of first-flush roof runoff and harvested rainwater

被引:129
作者
Gikas, Georgios D. [1 ]
Tsihrintzis, Vassilios A. [1 ]
机构
[1] Democritus Univ Thrace, Lab Ecol Engn & Technol, Dept Environm Engn, Sch Engn, GR-67100 Xanthi, Greece
关键词
Rainwater harvesting; Roof runoff quality; First-flush; Nutrients; Microbial indicators; Principal component analysis; SOUTHEAST QUEENSLAND; GREECE; AUSTRALIA;
D O I
10.1016/j.jhydrol.2012.08.020
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Six pilot rainwater harvesting systems were installed in five urban, suburban and rural houses, and on a university campus. The systems consist of horizontal gutters to collect roof drainage, and downdrains which end into one or two plastic storage tanks. Devices were also provided to remove first-flush water. Water quality was monitored in the storage tanks and the first-flush devices during the 2-year period from October 2006 to November 2008. Water samples were collected at a frequency of once every 10 days, and analyzed according to potable water specifications to determine major anions (e.g., SO24-, NO3-, NO2-, F-, Cl-) and cations (e.g., NH4+, Na+, K+, Ca2+, Mg2+), total suspended solids, alkalinity, total phosphorus and microbiological indicators (e.g., total coliforms, Escherichia coli, Streptococcus, Clostridium perfrigens, Pseudomonas syringae and total viable counts at 22 degrees C and 37 degrees C). Furthermore, temperature, pH, dissolved oxygen and electrical conductivity were measured in situ. The mean concentrations of chemical parameters in harvested rainwater (with the exception of NH4+) were below the limits set by the 98/93/EU directive for drinking water. Total coliforms were detected in 84.4-95.8% of the collected rainwater samples in the six tanks. E. coli, Streptococcus, C. perfrigens, P. syringae and total viable counts at 22 degrees C and 37 degrees C were found at low counts in samples of collected rainwater. The collected rainwater quality was found satisfactory regarding its physicochemical parameters, but not regarding its sanitary quality. Therefore, rainwater harvesting systems in this area could only supply water appropriate for use as gray water. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:115 / 126
页数:12
相关论文
共 20 条
  • [1] Real-time PCR detection of pathogenic microorganisms in roof-harvested rainwater in Southeast Queensland, Australia
    Ahmed, W.
    Huygens, F.
    Goonetilleke, A.
    Gardner, T.
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2008, 74 (17) : 5490 - 5496
  • [2] Health Risk from the Use of Roof-Harvested Rainwater in Southeast Queensland, Australia, as Potable or Nonpotable Water, Determined Using Quantitative Microbial Risk Assessment
    Ahmed, W.
    Vieritz, A.
    Goonetilleke, A.
    Gardner, T.
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2010, 76 (22) : 7382 - 7391
  • [3] [Anonymous], 2006, Guidelines for the Safe Use of Wastewater, Excreta and Greywater: Policy and regulatory aspects, V1
  • [4] [Anonymous], 2006, STANDARD METHODS EXA, DOI DOI 10.5860/CHOICE.37-2792
  • [5] The chemical composition of rainwater over Buyukcekmece Lake, Istanbul
    Basak, B
    Alagha, O
    [J]. ATMOSPHERIC RESEARCH, 2004, 71 (04) : 275 - 288
  • [6] Coombes P.J., 2002, P 3 INT HYDR WAT RES, P152
  • [7] Roof selection for rainwater harvesting: Quantity and quality assessments in Spain
    Farreny, Ramon
    Morales-Pinzon, Tito
    Guisasola, Albert
    Taya, Carlota
    Rieradevall, Joan
    Gabarrell, Xavier
    [J]. WATER RESEARCH, 2011, 45 (10) : 3245 - 3254
  • [8] Fewtrell L., 2007, URBAN WATER J, V4, P253, DOI DOI 10.1080/15730620701526097
  • [9] Variability of roof runoff quality
    Förster, J
    [J]. WATER SCIENCE AND TECHNOLOGY, 1999, 39 (05) : 137 - 144
  • [10] Water resources management in Crete and in the Aegean Islands, with emphasis on the utilization of non-conventional water sources
    Gikas, Petros
    Angelakis, Andreas N.
    [J]. DESALINATION, 2009, 248 (1-3) : 1049 - 1064