Three-dimensional echocardiographic evaluation of configuration and dynamics of the mitral annulus in patients fitted with an annuloplasty ring

被引:36
作者
Yamaura, Y [1 ]
Yoshida, K [1 ]
Hozumi, T [1 ]
Akasaka, T [1 ]
Okada, Y [1 ]
Yoshikawa, J [1 ]
机构
[1] OSAKA CITY UNIV,SCH MED,DEPT INTERNAL MED 1,OSAKA 545,JAPAN
关键词
D O I
10.2300/acari.6.43
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aims of the study: Three-dimensional (3D) echocardiography permits the objective analysis of structures and of pathologic conditions of complex geometry. Multiplane transesophageal echocardiography (TEE) permits 3D image sets of the heart to be produced from multiple 2D images by rotating the transducer, without changing its position. The purpose of this study was to clarify the capability of 3D echocardiography to evaluate the configuration and dynamics of the mitral annulus in patients fitted with an annuloplasty ring. Methods: Twenty patients who underwent mitral valve repair for pure mitral regurgitation (10 with a flexible Duran ring and 10 with a rigid Carpentier ring) were studied. Using a multiplane transesophageal probe, sequential tomographic images were obtained by rotating the transducer at 20 angular intervals around a 180 degrees are. 3D reconstructions were performed to produce dynamic 3D images of the mitral annulus in a manner that simulated visualization from the left atrium. Mitral annular configuration was assessed from volume-rendered display and extractive 3D imaging. Mitral annular area change was evaluated from selected long-axis cut planes. Results: The configuration and dynamics of the mitral annulus were visualized by 3D displays. In patients with a Duran ring, the mitral annulus had a non-planar configuration and mitral annular area changed during cardiac cycle (increased in diastole; reduced in atrial and ventricular systole; percentage reduction 25 +/- 2%). In patients with a Carpentier ring, the mitral annulus had a planar configuration and mitral annular area was effectively unchanged during the cardiac cycle. Conclusions: 3D echocardiography using a multiplane transesophageal probe is useful in evaluating the configuration and dynamics of the mitral annulus in patients fitted with an annuloplasty ring.
引用
收藏
页码:43 / 47
页数:5
相关论文
共 17 条
[1]   3-DIMENSIONAL AND 4-DIMENSIONAL CARDIOVASCULAR ULTRASOUND IMAGING - A NEW ERA FOR ECHOCARDIOGRAPHY [J].
BELOHLAVEK, M ;
FOLEY, DA ;
GERBER, TC ;
KINTER, TM ;
GREENLEAF, JF ;
SEWARD, JB .
MAYO CLINIC PROCEEDINGS, 1993, 68 (03) :221-240
[2]   3-DIMENSIONAL ULTRASOUND IMAGING OF THE ATRIAL SEPTUM - NORMAL AND PATHOLOGICAL ANATOMY [J].
BELOHLAVEK, M ;
FOLEY, DA ;
GERBER, TC ;
GREENLEAF, JF ;
SEWARD, JB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (06) :1673-1678
[3]  
CARPENTIER A, 1971, J THORAC CARDIOV SUR, V61, P1
[4]   CLINICAL AND HEMODYNAMIC PERFORMANCE OF A TOTALLY FLEXIBLE PROSTHETIC RING FOR ATRIOVENTRICULAR VALVE RECONSTRUCTION [J].
DURAN, CG ;
UBAGO, JLM .
ANNALS OF THORACIC SURGERY, 1976, 22 (05) :458-463
[5]  
DURAN CG, 1976, MITRAL VALVE PLURIDI, P549
[6]  
HOZUMI T, 1997, IN PRESS AM J CARDIO
[7]   THE RELATIONSHIP OF MITRAL ANNULAR SHAPE TO THE DIAGNOSIS OF MITRAL-VALVE PROLAPSE [J].
LEVINE, RA ;
TRIULZI, MO ;
HARRIGAN, P ;
WEYMAN, AE .
CIRCULATION, 1987, 75 (04) :756-767
[8]   DELINEATION OF SITE, RELATIVE SIZE AND DYNAMIC GEOMETRY OF ATRIAL SEPTAL-DEFECTS BY REAL-TIME 3-DIMENSIONAL ECHOCARDIOGRAPHY [J].
MARX, GR ;
FULTON, DR ;
PANDIAN, NG ;
VOGEL, M ;
CAO, QL ;
LUDOMIRSKY, A ;
DELABAYS, A ;
SUGENG, L ;
KLAS, B .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (02) :482-490
[9]   MULTIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHIC IMAGING AND 3-DIMENSIONAL RECONSTRUCTION - A PRELIMINARY-STUDY [J].
NANDA, NC ;
PINHEIRO, L ;
SANYAL, R ;
ROSENTHAL, S ;
KIRKLIN, JK .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1992, 9 (06) :667-676
[10]   SIZE AND MOTION OF THE MITRAL-VALVE ANNULUS IN MAN .1. A TWO-DIMENSIONAL ECHOCARDIOGRAPHIC METHOD AND FINDINGS IN NORMAL SUBJECTS [J].
ORMISTON, JA ;
SHAH, PM ;
TEI, C ;
WONG, M .
CIRCULATION, 1981, 64 (01) :113-120