Glucose biosensor based on glucose oxidase immobilized on unhybridized titanium dioxide nanotube arrays

被引:51
作者
Wang, Wei [1 ,2 ]
Xie, Yibing [1 ,2 ]
Wang, Yong [1 ]
Du, Hongxiu [1 ,2 ]
Xia, Chi [1 ,2 ]
Tian, Fang [1 ]
机构
[1] Southeast Univ, Sch Chem & Chem Engn, Nanjing 211189, Peoples R China
[2] Southeast Univ, Suzhou Res Inst, Suzhou 215123, Peoples R China
基金
高等学校博士学科点专项科研基金; 中国国家自然科学基金;
关键词
Titanium dioxide; Nanotube arrays; Glucose oxidase; Biosensor; Cross-linking; CROSS-LINKING; PERFORMANCE; TIO2;
D O I
10.1007/s00604-013-1121-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glucose biosensor has been fabricated by immobilizing glucose oxidase (GOx) on unhybridized titanium dioxide nanotube arrays using an optimized cross-linking technique. The TiO2 nanotube arrays were synthesized directly on a titanium substrate by anodic oxidation. The structure and morphology of electrode material were characterized by X-ray diffraction and scanning electron microscopy. The electrochemical performances of the glucose biosensor were conducted by cyclic voltammetry and chronoamperometry measurements. It gives a linear response to glucose in the 0.05 to 0.65 mM concentration range, with a correlation coefficient of 0.9981, a sensitivity of 199.6 mu A mM(-1) cm(-2), and a detection limit as low as 3.8 A mu M. This glucose biosensor exhibited high selectivity for glucose determination in the presence of ascorbic acid, sucrose and other common interfering substances. This glucose biosensor also performed good reproducibility and long-time storage stability. This optimized cross-linking technique could open a new avenue for other enzyme biosensors fabrication.
引用
收藏
页码:381 / 387
页数:7
相关论文
共 28 条
[21]   A Glucose Biosensor Based on Deposition of Glucose Oxidase onto Crystalline Gold Nanoparticle Modified Carbon Nanotube Electrode [J].
Rakhi, Raghavan Baby ;
Sethupathi, Kanikrishnan ;
Ramaprabhu, Sundara .
JOURNAL OF PHYSICAL CHEMISTRY B, 2009, 113 (10) :3190-3194
[22]   Glucose biosensor prepared by glucose oxidase encapsulated sol-gel and carbon-nanotube-modified basal plane pyrolytic graphite electrode [J].
Salimi, A ;
Compton, RG ;
Hallaj, R .
ANALYTICAL BIOCHEMISTRY, 2004, 333 (01) :49-56
[23]   Ti/TiO2 Nanotube Array/Ni Composite Electrodes for Nonenzymatic Amperometric Glucose Sensing [J].
Wang, Chengxiang ;
Yin, Longwei ;
Zhang, Luyuan ;
Gao, Rui .
JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (10) :4408-4413
[24]   A novel hydrogen peroxide biosensor based on the immobilization of hemoglobin on three-dimensionally ordered macroporous (3DOM) gold-nanoparticle-doped titanium dioxide (GTD) film [J].
Wei, Nannan ;
Xin, Xin ;
Du, Jiangyan ;
Li, Jianlin .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (08) :3602-3607
[25]  
Xu C-X, 2012, J SOLID STATE ELECTR, V90, P1
[26]   Biosensor for atrazin based on aligned carbon nanotubes modified with glucose oxidase [J].
Yang, Qing ;
Qu, Yongxia ;
Bo, Yang ;
Wen, Yin ;
Huang, Shasheng .
MICROCHIMICA ACTA, 2010, 168 (3-4) :197-203
[27]   Direct electrodeposition of a biocomposite consisting of reduced graphene oxide, chitosan and glucose oxidase on a glassy carbon electrode for direct sensing of glucose [J].
Yang, Shanli ;
Lu, Zhenzhen ;
Luo, Shenglian ;
Liu, Chengbin ;
Tang, Yanhong .
MICROCHIMICA ACTA, 2013, 180 (1-2) :127-135
[28]   An amperometric biosensor for the detection of hydrogen peroxide released from human breast cancer cells [J].
Zhao, Jing ;
Yan, Yalin ;
Zhu, Li ;
Li, Xiaoxi ;
Li, Genxi .
BIOSENSORS & BIOELECTRONICS, 2013, 41 :815-819