A preliminary verification of the floating reference measurement method for non-invasive blood glucose sensing

被引:17
|
作者
Min, Xiaolin [1 ]
Liu, Rong [1 ]
Fu, Bo [1 ]
Xu, Kexin [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
基金
国家高技术研究发展计划(863计划); 中国国家自然科学基金;
关键词
Floating reference positions; Diffusion approximation equation; Monte Carlo simulation; Blood glucose; NEAR-INFRARED SPECTROSCOPY; TISSUE-SIMULATING PHANTOMS; LIGHT; REFLECTANCE; SCATTERING; TRANSPORT;
D O I
10.1016/j.optlastec.2016.12.011
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the non-invasive sensing of blood glucose by near-infrared diffuse reflectance spectroscopy, the spectrum is highly susceptible to the unstable and complicated background variations from the human body and the environment. In in vitro analyses, background variations are usually corrected by the spectrum of a standard reference sample that has similar optical properties to the analyte of interest. However, it is hard to find a standard sample for the in vivo measurement. Therefore, the floating reference measurement method is proposed to enable relative measurements in vivo, where the spectra under some special source-detector distance, defined as the floating reference position, are insensitive to the changes in glucose concentration due to the absorption effect and scattering effect. Because the diffuse reflectance signals at the floating reference positions only reflect the information on background variations during the measurement, they can be used as the internal reference. In this paper, the theoretical basis of the floating reference positions in a semi-infinite turbid medium was discussed based on the steady-state diffusion equation and its analytical solutions in a semi infinite turbid medium (under the extrapolated boundary conditions). Then, Monte-Carlo (MC) simulations and in vitro experiments based on a custom-built continuous-moving spatially resolving double-fiber MR measurement system, configured with two types of light source, a super luminescent diode (SLD) and a super-continuum laser, were carried out to verify the existence of the floating reference position in 5%, 10% and 20% Intralipid solutions. The results showed that the simulation values of the floating reference positions are close to the theoretical results, with a maximum deviation of approximately 0.3 mm in 1100-1320 nm. Great differences can be observed in 1340-1400 nm because the optical properties of Intralipid in this region don not satisfy the conditions of the steady-state diffusion equation. For the in vitro experiments, floating reference positions exist in 1220 nm and 1320 nm under two types of light source, and the results are quite close. However, the reference positions obtained from experiments are further from the light source compared with those obtained in the MC simulation. For the turbid media and the wavelengths investigated, the difference is up to 1 mm. This study is important for the design of optical fibers to be applied in the floating reference measurement.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [31] Non-invasive Measurement Method of Blood Hematocrit for Management of Extracorporeal Circulation
    Ekuni, Shota
    Sankai, Yoshiyuki
    2014 IEEE/SICE INTERNATIONAL SYMPOSIUM ON SYSTEM INTEGRATION (SII), 2014, : 76 - 81
  • [32] The wavelength-dependent characteristic of the floating-reference point in the non-invasive glucose sensing - art. no. 68630R
    Liu, Rong
    Chen, Wenliang
    Yang, Yue
    Li, Yu
    Xu, Kexin
    OPTICAL DIAGNOSTICS AND SENSING VIII, 2008, 6863 : R8630 - R8630
  • [33] On Non-Invasive Glucose Measurements
    Aroutiounian, V. M.
    JOURNAL OF CONTEMPORARY PHYSICS-ARMENIAN ACADEMY OF SCIENCES, 2022, 57 (04) : 405 - 416
  • [34] The discussion about the complexity of samples and the prediction accuracy of glucose concentration in non-invasive blood glucose sensing
    Gu, XY
    Liu, R
    Chen, WL
    Xu, KX
    Complex Dynamics and Fluctuations in Biomedical Photonics II, 2005, 5696 : 222 - 231
  • [35] Non-invasive glucose sensing with near-infrared spectroscopy enhanced by optical measurement conditions reproduction technique
    Xu, KX
    Qiu, QJ
    Jiang, JY
    Yang, XY
    OPTICS AND LASERS IN ENGINEERING, 2005, 43 (10) : 1096 - 1106
  • [36] Characterization of an Inter-digitated Sensor for Non-invasive Blood-glucose Sensing
    Satish
    Sen, Kushal
    IETE JOURNAL OF RESEARCH, 2024, 70 (04) : 4203 - 4208
  • [37] The application of Monte Carlo method in the design of probe of non-invasive measurement of blood glucose - art. no. 60401S
    Wang, W
    Fu, GJ
    Hou, HL
    Gao, M
    ICMIT 2005: Mechatronics, MEMS, and Smart Materials, 2005, 6040 : S401 - S401
  • [38] Non-Invasive Glucose Measurement Technologies: Recent Advancements and Future Challenges
    Jain, Prateek
    Joshi, Amit M.
    Mohanty, Saraju P.
    Cenkeramaddi, Linga Reddy
    IEEE ACCESS, 2024, 12 : 61907 - 61936
  • [39] Internal floating reference method for noninvasive measurement of blood glucose with near-infrared spectroscopy
    Luo, Yun-Han
    Li, Ship-Ing
    Huang, Fu-Rong
    Chen, Zhe
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2008, 10 (03): : 592 - 596
  • [40] Non-invasive Blood Glucose Measurement Scheme Based on Near-infrared Spectroscopy
    Wang Shulei
    Yuan Xueguang
    Zhang Yangan
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2017,