A preliminary verification of the floating reference measurement method for non-invasive blood glucose sensing

被引:17
|
作者
Min, Xiaolin [1 ]
Liu, Rong [1 ]
Fu, Bo [1 ]
Xu, Kexin [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
基金
国家高技术研究发展计划(863计划); 中国国家自然科学基金;
关键词
Floating reference positions; Diffusion approximation equation; Monte Carlo simulation; Blood glucose; NEAR-INFRARED SPECTROSCOPY; TISSUE-SIMULATING PHANTOMS; LIGHT; REFLECTANCE; SCATTERING; TRANSPORT;
D O I
10.1016/j.optlastec.2016.12.011
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the non-invasive sensing of blood glucose by near-infrared diffuse reflectance spectroscopy, the spectrum is highly susceptible to the unstable and complicated background variations from the human body and the environment. In in vitro analyses, background variations are usually corrected by the spectrum of a standard reference sample that has similar optical properties to the analyte of interest. However, it is hard to find a standard sample for the in vivo measurement. Therefore, the floating reference measurement method is proposed to enable relative measurements in vivo, where the spectra under some special source-detector distance, defined as the floating reference position, are insensitive to the changes in glucose concentration due to the absorption effect and scattering effect. Because the diffuse reflectance signals at the floating reference positions only reflect the information on background variations during the measurement, they can be used as the internal reference. In this paper, the theoretical basis of the floating reference positions in a semi-infinite turbid medium was discussed based on the steady-state diffusion equation and its analytical solutions in a semi infinite turbid medium (under the extrapolated boundary conditions). Then, Monte-Carlo (MC) simulations and in vitro experiments based on a custom-built continuous-moving spatially resolving double-fiber MR measurement system, configured with two types of light source, a super luminescent diode (SLD) and a super-continuum laser, were carried out to verify the existence of the floating reference position in 5%, 10% and 20% Intralipid solutions. The results showed that the simulation values of the floating reference positions are close to the theoretical results, with a maximum deviation of approximately 0.3 mm in 1100-1320 nm. Great differences can be observed in 1340-1400 nm because the optical properties of Intralipid in this region don not satisfy the conditions of the steady-state diffusion equation. For the in vitro experiments, floating reference positions exist in 1220 nm and 1320 nm under two types of light source, and the results are quite close. However, the reference positions obtained from experiments are further from the light source compared with those obtained in the MC simulation. For the turbid media and the wavelengths investigated, the difference is up to 1 mm. This study is important for the design of optical fibers to be applied in the floating reference measurement.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [21] Non-invasive blood glucose measurement using quantum cascade laser
    Matsuura, Y.
    Koyama, T.
    QUANTUM SENSING AND NANO ELECTRONICS AND PHOTONICS XVI, 2019, 10926
  • [22] Non-invasive Blood Glucose Measurement Based on ATR Infrared Spectroscopy
    Ishizawa, Hiroaki
    Muro, Akinobu
    Takano, Tomohiro
    Honda, Kazuya
    Kanai, Hiroyuki
    2008 PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-7, 2008, : 292 - 295
  • [23] Study on the Experimental Application of Floating-Reference Method to Noninvasive Blood Glucose Sensing
    Yu Hui
    Qi Dan
    Li Heng-da
    Xu Ke-xin
    Yuan Wei-jie
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (03) : 770 - 774
  • [24] A novel non-invasive, method of blood glucose measurement using FT-Mid-IR spectroscopy
    Zhao, Y
    Zhang, YF
    Yang, LM
    Xu, YZ
    Weng, SF
    Yang, ZL
    Wu, HZ
    Zhou, WJ
    Xu, DF
    Wu, JG
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2005, 26 (06): : 1052 - 1054
  • [25] BpMC: A Novel Algorithm Retrieving Multilayered Tissue Bio-optical Properties for Non-invasive Blood Glucose Measurement
    Liu, Weijie
    Huang, Anpeng
    Wang, Ping
    2017 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE (BIBM), 2017, : 451 - 456
  • [26] Overcoming Individual Discrepancies, a Learning Model for Non-Invasive Blood Glucose Measurement
    Liu, Weijie
    Huang, Anpeng
    Wan, Ping
    APPLIED SCIENCES-BASEL, 2019, 9 (01):
  • [27] Non-invasive Blood Glucose Measurement Performance Analysis through UWB Imaging
    Ali, Md Shawkat
    Shoumy, N. J.
    Khatun, S.
    Kamarudin, L. M.
    Vijayasarveswari, V.
    2016 3RD INTERNATIONAL CONFERENCE ON ELECTRONIC DESIGN (ICED), 2016, : 513 - 516
  • [28] Non-invasive Blood Glucose Measurement Based on mid-Infrared Spectroscopy
    Chen, Yang
    Liu, Jiang
    Pan, Zhenni
    Shimamoto, Shirgeru
    2020 IEEE 17TH ANNUAL CONSUMER COMMUNICATIONS & NETWORKING CONFERENCE (CCNC 2020), 2020,
  • [29] An optimized non-invasive glucose sensing based on scattering and absorption separating using near-infrared spectroscopy
    Han, Tongshuai
    Liu, Xueyu
    Liu, Jin
    Xu, Kexin
    OPTICAL DIAGNOSTICS AND SENSING XIX: TOWARD POINT-OF-CARE DIAGNOSTICS, 2019, 10885
  • [30] Extraction of glucose information in blood glucose measurement by non-invasive near-infrared spectra
    Liu, R
    Chen, WL
    Gu, XY
    Luo, YH
    Xu, KX
    OPTICAL DIAGNOSTICS AND SENSING V, 2005, 5702 : 30 - 38