A preliminary verification of the floating reference measurement method for non-invasive blood glucose sensing

被引:17
|
作者
Min, Xiaolin [1 ]
Liu, Rong [1 ]
Fu, Bo [1 ]
Xu, Kexin [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
来源
基金
国家高技术研究发展计划(863计划); 中国国家自然科学基金;
关键词
Floating reference positions; Diffusion approximation equation; Monte Carlo simulation; Blood glucose; NEAR-INFRARED SPECTROSCOPY; TISSUE-SIMULATING PHANTOMS; LIGHT; REFLECTANCE; SCATTERING; TRANSPORT;
D O I
10.1016/j.optlastec.2016.12.011
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the non-invasive sensing of blood glucose by near-infrared diffuse reflectance spectroscopy, the spectrum is highly susceptible to the unstable and complicated background variations from the human body and the environment. In in vitro analyses, background variations are usually corrected by the spectrum of a standard reference sample that has similar optical properties to the analyte of interest. However, it is hard to find a standard sample for the in vivo measurement. Therefore, the floating reference measurement method is proposed to enable relative measurements in vivo, where the spectra under some special source-detector distance, defined as the floating reference position, are insensitive to the changes in glucose concentration due to the absorption effect and scattering effect. Because the diffuse reflectance signals at the floating reference positions only reflect the information on background variations during the measurement, they can be used as the internal reference. In this paper, the theoretical basis of the floating reference positions in a semi-infinite turbid medium was discussed based on the steady-state diffusion equation and its analytical solutions in a semi infinite turbid medium (under the extrapolated boundary conditions). Then, Monte-Carlo (MC) simulations and in vitro experiments based on a custom-built continuous-moving spatially resolving double-fiber MR measurement system, configured with two types of light source, a super luminescent diode (SLD) and a super-continuum laser, were carried out to verify the existence of the floating reference position in 5%, 10% and 20% Intralipid solutions. The results showed that the simulation values of the floating reference positions are close to the theoretical results, with a maximum deviation of approximately 0.3 mm in 1100-1320 nm. Great differences can be observed in 1340-1400 nm because the optical properties of Intralipid in this region don not satisfy the conditions of the steady-state diffusion equation. For the in vitro experiments, floating reference positions exist in 1220 nm and 1320 nm under two types of light source, and the results are quite close. However, the reference positions obtained from experiments are further from the light source compared with those obtained in the MC simulation. For the turbid media and the wavelengths investigated, the difference is up to 1 mm. This study is important for the design of optical fibers to be applied in the floating reference measurement.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [1] Phantom Experimental Validation of Near Floating Reference Measuring Method in Non-Invasive Blood Glucose Sensing
    Xia Dan-dan
    Han Guang
    Yu Xu-yao
    Li Chen-xi
    Liu Rong
    Jiang Jing-ying
    Xu Ke-xin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (06) : 1941 - 1945
  • [2] Method and device for non-invasive blood glucose measurement
    Amerov, AK
    Jeon, KJ
    Kim, YJ
    Yoon, G
    OPTICAL DIAGNOSTICS OF BIOLOGICAL FLUIDS IV, PROCEEDINGS OF, 1999, 3599 : 33 - 42
  • [3] An original method for non-invasive glucose measurement: Preliminary results
    Alavi, SM
    Gourzi, A
    Rouane, A
    Nadi, M
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 3318 - 3320
  • [4] Study on optical measurement conditions for non-invasive blood glucose sensing
    Xu, KX
    Chen, WL
    Jiang, JY
    Qiu, QJ
    COMPLEX DYNAMICS, FLUCTUATIONS, CHAOS, AND FRACTALS IN BIOMEDICAL PHOTONICS, 2004, 5 (19): : 83 - 91
  • [5] Net analyte signal with floating reference theory in non-invasive blood glucose sensing by near-infrared spectroscopy
    Zhang, Wanjie
    Liu, Rong
    Zhang, Wen
    Zheng, Jiaxiang
    Xu, Kexin
    CHINESE OPTICS LETTERS, 2012, 10 (08)
  • [6] Net analyte signal with floating reference theory in non-invasive blood glucose sensing by near-infrared spectroscopy
    张婉洁
    刘蓉
    张雯
    郑加祥
    徐可欣
    ChineseOpticsLetters, 2012, 10 (08) : 74 - 77
  • [7] Non-invasive Blood Glucose Measurement System
    Deepthi, S.
    Valke, Nikita S.
    Parvathy, J. P.
    Sai, Anjaly Krishna
    Sajjan, Guttappa
    2019 5TH IEEE INTERNATIONAL WIE CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (WIECON-ECE 2019), 2019,
  • [8] Reference point of floating-reference method for blood glucose sensing
    Yang, Yue
    Chen, Wenliang
    Shi, Zhenzhi
    Xu, Kexin
    CHINESE OPTICS LETTERS, 2010, 8 (04) : 421 - 424
  • [9] Reference point of floating-reference method for blood glucose sensing
    杨越
    陈文亮
    史振志
    徐可欣
    ChineseOpticsLetters, 2010, 8 (04) : 421 - 424
  • [10] Phantom Experimental Verification of Non-invasive Blood Glucose Measurement Based on Visible Image
    Li Fen
    Zhao Yuejin
    Kong Lingqin
    Liu Ming
    Dong Liquan
    Hui Mei
    Liu Xiaohua
    ACTA OPTICA SINICA, 2020, 40 (06)