Local tumor control probability to evaluate an applicator-guided volumetric-modulated arc therapy solution as alternative of 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecological cancer

被引:6
作者
Pedicini, Piernicola [1 ]
Strigari, Lidia [2 ]
Caivano, Rocchina [1 ]
Fiorentino, Alba [1 ]
Califano, Giorgia [1 ]
Nappi, Antonio [1 ]
Improta, Giuseppina [1 ]
Storto, Giovanni [1 ]
Cozzolino, Mariella [1 ]
Chiumento, Costanza [1 ]
Fusco, Vincenzo [1 ]
Vavassori, Andrea [3 ]
Benassi, Marcello [4 ]
Orecchia, Roberto [3 ,5 ]
Salvatore, Marco [1 ,6 ]
机构
[1] IRCCS Reg Canc Hosp CROB, Rionero In Vulture, Italy
[2] Regina Elena Inst Canc Res, Rome, Italy
[3] IEO European Inst Oncol, Milan, Italy
[4] Sci Inst Tumours Romagna IRST, Meldola, Italy
[5] Univ Milan, Milan, Italy
[6] IRCCS SDN Fdn, Naples, Italy
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2013年 / 14卷 / 02期
关键词
VMAT; 3D brachytherapy; EUD; TCP; DOSE-RATE BRACHYTHERAPY; CERVIX CANCER; RADIATION-THERAPY; UTERINE CERVIX; RADIOTHERAPY; RECOMMENDATIONS; DISTRIBUTIONS; CARCINOMA; PARAMETERS; DENSITY;
D O I
10.1120/jacmp.v14i2.4075
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the applicator-guided volumetric-modulated arc therapy (AGVMAT) solution as an alternative to high-dose-rate brachytherapy (HDR-BRT) treatment of the vaginal vault in patients with gynecological cancer (GC). AGVMAT plans for 51 women were developed. The volumetric scans used for plans were obtained with an implanted CT-compatible vaginal cylinder which provides spatial registration and immobilization of the gynecologic organs. Dosimetric and radiobiological comparisons for planning target volume (PTV) and organs at risk (OARs) were performed by means of a dose-volume histogram (DVH), equivalent uniform dose (EUD), and local tumor control probability (LTCP). In addition, the integral dose and the overall delivery time, were evaluated. The HDR-BRT averages of EUD and minimum LTCP were significantly higher than those of AGVMAT. Doses for the OARs were comparable for the bladder and sigmoid, while, although HDR-BRT was able to better spare the bowel, AGVMAT provided a significant reduction of d(2cc), d(1cc), and d(max) (p < 0.01) for the rectum. AGVMAT integral doses were higher than HDR-BRT with low values in both cases. Delivery times were about two or three times higher for HDR-BRT with respect to the single arc technique (AGVMAT1) and dual arc technique (AGVMAT2), respectively. The applicator-guided volumetric-modulated arc therapy seems to have the potential of improving rectum avoidance. However, brachytherapy improves performance in terms of PTV coverage, as demonstrated by a greater EUD and better LTCP curves.
引用
收藏
页码:146 / 157
页数:12
相关论文
共 3 条
  • [1] Dosimetric comparison of vaginal vault brachytherapy vs applicator-guided stereotactic body radiotherapy with volumetric modulated arc therapy and helical tomotherapy for endometrium cancer patients
    Yildirim, Berna Akkus
    Dolek, Yemliha
    Guler, Ozan Cem
    Arslan, Gungor
    Onal, Cem
    MEDICAL DOSIMETRY, 2019, 44 (04) : 332 - 338
  • [2] Comparative dosimetric and radiobiological assessment among a nonstandard RapidArc, standard RapidArc, classical intensity-modulated radiotherapy, and 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecologic cancer
    Pedicini, Piernicola
    Caivano, Rocchina
    Fiorentino, Alba
    Strigari, Lidia
    Califano, Giorgia
    Barbieri, Viviana
    Sanpaolo, Piero
    Castaldo, Giovanni
    Benassi, Marcello
    Fusco, Vincenzo
    MEDICAL DOSIMETRY, 2012, 37 (04) : 347 - 352
  • [3] Outcome and toxicity of chemoradiation using volumetric modulated arc therapy followed by 3D image-guided brachytherapy for cervical cancer: Vietnam National Cancer Hospital experience
    Van Anh, Dang Thi
    Thang, Vu Hong
    Dung, To Anh
    Huyen, Tran Thi
    Nhan, Dao Thi Thanh
    Van Giang, Bui
    Huyen, Phung Thi
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2023, 28 (06) : 784 - 793