Characterization of a solar photovoltaic/loop-heat-pipe heat pump water heating system

被引:118
作者
Zhang, Xingxing [1 ]
Zhao, Xudong [1 ]
Xu, Jihuan [2 ]
Yu, Xiaotong [3 ]
机构
[1] De Montfort Univ, Inst Energy & Sustainable Dev, Leicester LE1 9BH, Leics, England
[2] Shanghai Pacific Energy Ctr, Shanghai, Peoples R China
[3] Shanghai Solar Energy Res Ctr, Shanghai, Peoples R China
关键词
PV; Loop heat pipe; Heat pump; Efficiency; Solar; Energy Performance; THERMAL COLLECTOR; PV ELEMENTS; FLUID-FLOW; ONE SIDE; PERFORMANCE; YIELD; MODEL;
D O I
10.1016/j.apenergy.2012.06.039
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper introduced the concept, potential application and benefits relating to a novel solar photovoltaic/loop-heat-pipe (PV/LHP) heat pump system for hot water generation. On this basis, the paper reported the process and results of characterizing the performance of such a system, which was undertaken through dedicated thermo-fluid and energy balance analyses, computer model development and operation, and experimental verification and modification. The fundamental heat transfer, fluid flow and photovoltaic governing equations were applied to characterize the energy conversion and transfer processes occurring in each part and whole system layout; while the energy balance approach was utilized to enable inter-connection and resolution of the grouped equations. As a result, a dedicated computer model was developed and used to calculate the operational parameters, optimise the geometrical configurations and sizes, and recommend the appropriate operational condition relating to the system. Further, an experimental rig was constructed and utilized to acquire the relevant measurement data that thus enabled the parallel comparison between the simulation and experiment. It is concluded that the testing and modelling results are in good agreement, indicating that the model has the reasonable accuracy in predicting the system's performance. Under the given experimental conditions, the electrical, thermal and overall efficiency of the PV/LHP module were around 10%, 40% and 50% respectively; whilst the system's overall performance coefficient (COPPV/T) was 8.7. Impact of the operational parameters (i.e. solar radiation, air temperature, air velocity, heat-pump's evaporation temperature, glazing covers, and number of the absorbing heat pipes) to the performance of the system (in terms of efficiencies of the PV/LHP module and the system's overall performance coefficient COPPV/T) was investigated individually. The results indicated that lower solar radiation, lower air temperature, higher air velocity and smaller cover number led to enhanced electrical efficiency but reduced thermal efficiency of the module; whereas lower heat-pump's evaporation temperature and larger number of heat absorbing pipes gave rise to both thermal and electrical efficiencies of the module. The research results would assist in developing a high efficient solar (space or hot water) heating system and thus contribute to realisation of the energy saving and associated carbon emission targets set for buildings globally. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1229 / 1245
页数:17
相关论文
共 41 条
[1]   Evaluating the possible configurations of incorporating the loop heat pipe into the air-conditioning systems [J].
Alklaibi, A. M. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (05) :807-815
[2]  
[Anonymous], 2009, SOLAR ENERGY ENG PRO
[3]  
[Anonymous], 2010, TECHN ROADM SOL PHOT
[4]  
[Anonymous], 1958, T C US SOL EN
[5]   Model calculations on a flat-plate solar heat collector with integrated solar cells [J].
Bergene, T ;
Lovvik, OM .
SOLAR ENERGY, 1995, 55 (06) :453-462
[6]   Thermal regulation of photovoltaic cladding [J].
Brinkworth, BJ ;
Cross, BM ;
Marshall, RH ;
Yang, HX .
SOLAR ENERGY, 1997, 61 (03) :169-178
[7]   Experimental study on a hybrid photovoltaic/heat pump system [J].
Chen, Hongbing ;
Riffat, Saffa B. ;
Fu, Yu .
APPLIED THERMAL ENGINEERING, 2011, 31 (17-18) :4132-4138
[8]   A review on photovoltaic/thermal hybrid solar technology [J].
Chow, T. T. .
APPLIED ENERGY, 2010, 87 (02) :365-379
[9]   Annual performance of building-integrated photovoltaic/water-heating system for warm climate application [J].
Chow, T. T. ;
Chan, A. L. S. ;
Fong, K. F. ;
Lin, Z. ;
He, W. ;
Ji, I. .
APPLIED ENERGY, 2009, 86 (05) :689-696
[10]   Energy and exergy analysis of photovoltaic-thermal collector with and without glass cover [J].
Chow, T. T. ;
Pei, G. ;
Fong, K. F. ;
Lin, Z. ;
Chan, A. L. S. ;
Ji, J. .
APPLIED ENERGY, 2009, 86 (03) :310-316