Intubation by paramedics using the ILMA or AirTraq, KingVision, and Macintosh laryngoscopes in vehicle-entrapped patients: a manikin study

被引:19
作者
Gaszynska, Ewelina [1 ]
Samsel, Piotr [2 ]
Stankiewicz-Rudnicki, Michal [3 ]
Wieczorek, Andrzej [3 ]
Gaszynski, Tomasz [2 ]
机构
[1] Med Univ Lodz, Dept Hyg & Hlth Promot, PL-92216 Lodz, Poland
[2] Med Univ Lodz, Dept Emergency Med & Disaster Med, PL-92216 Lodz, Poland
[3] Med Univ Lodz, Dept Anesthesiol & Intens Therapy, PL-92216 Lodz, Poland
关键词
airway management; laryngeal mask; trapped; videolaryngoscope; LARYNGEAL-MASK AIRWAY; TRACHEAL INTUBATION; RESTRICTED ACCESS; MANAGEMENT;
D O I
10.1097/MEJ.0b013e3283632fb6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Four devices were compared in a simulated scenario of a vehicle-entrapped patient: standard Macintosh laryngoscope, intubating laryngeal mask (ILMA), AirTraq optical laryngoscope, and KingVision videolaryngoscope. A group of 30 final-year paramedic students intubated a manikin placed in a sitting position under a desk simulating the roof of a car. Time of endotracheal intubation and success ratio were recorded. The baseline time of intubation was measured in a manikin lying down flat on the ground. The mean time to intubation was 13.9 +/- 6.6, 24.7 +/- 4.7, 25.2 +/- 3.7, and 23.9 +/- 4.2 s; the first attempt success ratios for devices were 29/30, 18/30, 6/30, and 18/30; and the baseline time of intubation was 14.3 +/- 6.5, 16.7 +/- 4.7, 22.9 +/- 12.6, and 18.1 +/- 5.0 s for ILMA, Macintosh laryngoscope, Airtraq, and KingVision, respectively. In emergency situations with very limited access to the patient, ILMA is the most effective device for intubation by paramedics. (C) 2014 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:61 / 64
页数:4
相关论文
共 40 条
[31]   A comparative evaluation of Airtraq and Hansraj Video laryngoscopes in patients undergoing tracheal intubation with cervical spine immobilization - A randomized prospective study [J].
Varshney, Poojangi ;
Ahmed, Syed M. ;
Siddiqui, Obaid A. ;
Abu Nadeem ;
Ajmal, P. M. .
JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2021, 37 (03) :336-341
[32]   Comparison of C-MAC® conventional blade, D-Blade™, and Macintosh laryngoscopes for endotracheal intubation in patients with simulated immobilization using manual in-line stabilization: A randomized trial [J].
Dabas, M. ;
Gupta, M. ;
Mohanan, S. ;
Kaushik, P. ;
Lall, R. .
JOURNAL OF POSTGRADUATE MEDICINE, 2024, 70 (03) :149-153
[33]   Assessment of the Possibility of Using the Laryngoscopes Macintosh, McCoy, Miller, Intubrite, VieScope and I-View for Intubation in Simulated Out-of-Hospital Conditions by People without Clinical Experience: A Randomized Crossover Manikin Study [J].
Ratajczyk, Pawel ;
Kluj, Przemyslaw ;
Dolder, Przemyslaw ;
Szmyd, Bartosz ;
Gaszynski, Tomasz .
HEALTHCARE, 2023, 11 (05)
[34]   Endotracheal Intubation by Paramedics Using Neodymium Magnet and Modified Stylet in Simulated Difficult Airway: A Prospective, Randomized, Crossover Manikin Study [J].
Bilge, Sedat ;
Tezel, Onur ;
Acar, Yahya Ayhan ;
Aydin, Guclu ;
Aydin, Attila ;
Ozkan, Gokhan .
EMERGENCY MEDICINE INTERNATIONAL, 2019, 2019
[35]   Safety assessment of using macintosh laryngoscope, airtraq, I-view, UESCOPE by non-clinically experienced individuals on a manikin model: A randomized cross-over study [J].
Ratajczyk, Pawel ;
Kluj, Przemyslaw ;
Wasiak, Krzysztof ;
Szmyd, Bartosz ;
Baginska, Karolina ;
Gaszynski, Tomasz .
TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2024, 56
[36]   Can the ETView VivaSight SL Rival Conventional Intubation Using the Macintosh Laryngoscope During Adult Resuscitation by Novice Physicians? A Randomized Crossover Manikin Study [J].
Szarpak, Lukasz ;
Truszewski, Zenon ;
Czyzewski, Lukasz ;
Kurowski, Andrzej .
MEDICINE, 2015, 94 (21)
[37]   MUSCLE ACTIVITY DURING ENDOTRACHEAL INTUBATION USING 4 LARYNGOSCOPES (MACINTOSH LARYNGOSCOPE, INTUBRITE, TRUVIEW EVO2 AND KING VISION) - A COMPARATIVE STUDY [J].
Gaszynski, Tomasz ;
Jakubiak, Jakub .
MEDYCYNA PRACY, 2016, 67 (02) :155-162
[38]   Low skill fibreoptic intubation using i-gel™ and air-Q™ in simulated difficult airways: A randomised study in manikin and in patients [J].
Sim, Jacqueline Xiu Ling ;
Liew, Geoffrey Haw Chieh ;
Abdullah, Hairil ;
Wong, Theodore Gar Ling ;
Wong, Patrick .
PROCEEDINGS OF SINGAPORE HEALTHCARE, 2020, 29 (03) :156-162
[39]   A manikin study comparing the performance of the GlideScope(R), the Airtraq(R)and the C-MAC(R)in endotracheal intubation using suction-assisted laryngoscopy airway decontamination techniques in a simulated massive haematemesis scenario by emergency doctors [J].
Wong, Ching Hin Kevin ;
Ko, Shing ;
Wong, Oi Fung ;
Ma, Hing Man ;
Lit, Chau Hung Albert ;
Shih, Yau Ngai .
HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2021, 28 (05) :291-304
[40]   Efficacy of the Disposcope endoscope, a new video laryngoscope, for endotracheal intubation in patients with cervical spine immobilisation by semirigid neck collar: comparison with the Macintosh laryngoscope using a simulation study on a manikin [J].
Park, Sang O. ;
Shin, Dong Hyuk ;
Lee, Kyeong Ryong ;
Hong, Dae Young ;
Kim, Eun Jung ;
Baek, Kwang Je .
EMERGENCY MEDICINE JOURNAL, 2013, 30 (04) :270-274