Intubation by paramedics using the ILMA or AirTraq, KingVision, and Macintosh laryngoscopes in vehicle-entrapped patients: a manikin study

被引:18
作者
Gaszynska, Ewelina [1 ]
Samsel, Piotr [2 ]
Stankiewicz-Rudnicki, Michal [3 ]
Wieczorek, Andrzej [3 ]
Gaszynski, Tomasz [2 ]
机构
[1] Med Univ Lodz, Dept Hyg & Hlth Promot, PL-92216 Lodz, Poland
[2] Med Univ Lodz, Dept Emergency Med & Disaster Med, PL-92216 Lodz, Poland
[3] Med Univ Lodz, Dept Anesthesiol & Intens Therapy, PL-92216 Lodz, Poland
关键词
airway management; laryngeal mask; trapped; videolaryngoscope; LARYNGEAL-MASK AIRWAY; TRACHEAL INTUBATION; RESTRICTED ACCESS; MANAGEMENT;
D O I
10.1097/MEJ.0b013e3283632fb6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Four devices were compared in a simulated scenario of a vehicle-entrapped patient: standard Macintosh laryngoscope, intubating laryngeal mask (ILMA), AirTraq optical laryngoscope, and KingVision videolaryngoscope. A group of 30 final-year paramedic students intubated a manikin placed in a sitting position under a desk simulating the roof of a car. Time of endotracheal intubation and success ratio were recorded. The baseline time of intubation was measured in a manikin lying down flat on the ground. The mean time to intubation was 13.9 +/- 6.6, 24.7 +/- 4.7, 25.2 +/- 3.7, and 23.9 +/- 4.2 s; the first attempt success ratios for devices were 29/30, 18/30, 6/30, and 18/30; and the baseline time of intubation was 14.3 +/- 6.5, 16.7 +/- 4.7, 22.9 +/- 12.6, and 18.1 +/- 5.0 s for ILMA, Macintosh laryngoscope, Airtraq, and KingVision, respectively. In emergency situations with very limited access to the patient, ILMA is the most effective device for intubation by paramedics. (C) 2014 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:61 / 64
页数:4
相关论文
共 40 条
  • [21] Comparison of the time to successful endotracheal intubation using the Macintosh laryngoscope or KingVision video laryngoscope in the emergency department: A prospective observational study
    Mallick, Tanvi
    Verma, Ankur
    Jaiswal, Sanjay
    Haldar, Meghna
    Sheikh, Wasil Rasool
    Vishen, Amit
    Snehy, Abhishek
    Ahuja, Rinkey
    TURKISH JOURNAL OF EMERGENCY MEDICINE, 2020, 20 (01): : 22 - 27
  • [22] A COMPARISON OF TRACHEAL INTUBATION USING THE AIRTRAQ AND THE MACINTOSH LARYNGOSCOPE- A PROSPECTIVE STUDY
    Gandhi, Ravindra
    Attar, Asha
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2019, 8 (28): : 2283 - 2287
  • [23] Tracheal intubation for a difficult airway using Airway scope®, KingVision® and McGRATH®: a comparative manikin study of inexperienced personnel
    J Itai
    Y Tanabe
    T Nishida
    T Inagawa
    Y Torikoshi
    Y Kida
    T Tamura
    K Ota
    T Otani
    T Sadamori
    K Une
    R Tsumura
    Y Iwasaki
    N Hirohashi
    K Tanigawal
    Critical Care, 17 (Suppl 2):
  • [24] Force and pressure distribution using Macintosh and GlideScope laryngoscopes in normal and difficult airways: a manikin study
    Carassiti, M.
    Zanzonico, R.
    Cecchini, S.
    Silvestri, S.
    Cataldo, R.
    Agro, F. E.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (01) : 146 - 151
  • [25] Ability of paramedics to perform endotracheal intubation during continuous chest compressions: a randomized cadaver study comparing Pentax AWS and Macintosh laryngoscopes
    Truszewski, Zenon
    Czyzewski, Lukasz
    Smereka, Jacek
    Krajewski, Pawel
    Fudalej, Marcin
    Madziala, Marcin
    Szarpak, Lukasz
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (09) : 1835 - 1839
  • [26] A manikin study comparing the performance of traditional Macintosh laryngoscope, GlideScope®, Airtraq®, and video-optical intubation stylet in endotracheal intubation used by emergency doctors in simulated difficult airway intubation: A pilot study
    Li, Yu On
    Wong, Oi Fung
    Ko, Shing
    Ma, Hing Man
    Lit, Chau Hung Albert
    Shih, Yau Ngai
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2023, 30 (03) : 179 - 188
  • [27] Comparison of McGrath Series 3 and Macintosh Laryngoscopes for Tracheal Intubation in Patients With Normal Airway by Inexperienced Anesthetists A Randomized Study
    Liu, Zi-Jia
    Yi, Jie
    Guo, Wen-Juan
    Ma, Chao
    Huang, Yu-Guang
    MEDICINE, 2016, 95 (02)
  • [28] Airtraq Laryngoscope Versus the Conventional Macintosh Laryngoscope During Pediatric Intubation Performed by Nurses: A Randomized Crossover Manikin Study With Three Airway Scenarios
    Szarpak, Lukasz
    Karczewska, Katarzyna
    Czyzewski, Lukasz
    Truszewski, Zenon
    Kurowski, Andrzej
    PEDIATRIC EMERGENCY CARE, 2017, 33 (11) : 735 - 739
  • [29] Effect of cardiopulmonary resuscitation on intubation using a Macintosh laryngoscope, the Air Way Scope, and the gum elastic bougie: A manikin study
    Maruyama, K.
    Tsukamoto, S.
    Ohno, S.
    Kobayashi, K.
    Nakagawa, H.
    Kitamura, A.
    Hayashida, M.
    RESUSCITATION, 2010, 81 (08) : 1014 - 1018
  • [30] Performance and skill retention of intubation by paramedics using seven different airway devices-A manikin study
    Ruetzler, Kurt
    Roessler, Bernhard
    Potura, Lukasz
    Priemayr, Anita
    Robak, Oliver
    Schuster, Ernst
    Frass, Michael
    RESUSCITATION, 2011, 82 (05) : 593 - 597