Intubation by paramedics using the ILMA or AirTraq, KingVision, and Macintosh laryngoscopes in vehicle-entrapped patients: a manikin study

被引:18
|
作者
Gaszynska, Ewelina [1 ]
Samsel, Piotr [2 ]
Stankiewicz-Rudnicki, Michal [3 ]
Wieczorek, Andrzej [3 ]
Gaszynski, Tomasz [2 ]
机构
[1] Med Univ Lodz, Dept Hyg & Hlth Promot, PL-92216 Lodz, Poland
[2] Med Univ Lodz, Dept Emergency Med & Disaster Med, PL-92216 Lodz, Poland
[3] Med Univ Lodz, Dept Anesthesiol & Intens Therapy, PL-92216 Lodz, Poland
关键词
airway management; laryngeal mask; trapped; videolaryngoscope; LARYNGEAL-MASK AIRWAY; TRACHEAL INTUBATION; RESTRICTED ACCESS; MANAGEMENT;
D O I
10.1097/MEJ.0b013e3283632fb6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Four devices were compared in a simulated scenario of a vehicle-entrapped patient: standard Macintosh laryngoscope, intubating laryngeal mask (ILMA), AirTraq optical laryngoscope, and KingVision videolaryngoscope. A group of 30 final-year paramedic students intubated a manikin placed in a sitting position under a desk simulating the roof of a car. Time of endotracheal intubation and success ratio were recorded. The baseline time of intubation was measured in a manikin lying down flat on the ground. The mean time to intubation was 13.9 +/- 6.6, 24.7 +/- 4.7, 25.2 +/- 3.7, and 23.9 +/- 4.2 s; the first attempt success ratios for devices were 29/30, 18/30, 6/30, and 18/30; and the baseline time of intubation was 14.3 +/- 6.5, 16.7 +/- 4.7, 22.9 +/- 12.6, and 18.1 +/- 5.0 s for ILMA, Macintosh laryngoscope, Airtraq, and KingVision, respectively. In emergency situations with very limited access to the patient, ILMA is the most effective device for intubation by paramedics. (C) 2014 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:61 / 64
页数:4
相关论文
共 40 条
  • [1] A comparison of the Airtraq®, McGrath®, and Macintosh laryngoscopes for difficult paediatric intubation: A manikin study
    Owada, Gen
    Mihara, Takahiro
    Inagawa, Gaku
    Asakura, Ayako
    Goto, Takahisa
    Ka, Koui
    PLOS ONE, 2017, 12 (02):
  • [2] Airtraq, LMA CTrach and Macintosh Laryngoscopes in Tracheal Intubation Training: A Randomized Comparative Manikin Study
    Saracoglu, Ayten
    Dal, Didem
    Baygin, Omer
    Gogus, Fevzi Yilmaz
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2016, 44 (02) : 76 - 80
  • [3] Comparison of the ETView Single Lumen and Macintosh laryngoscopes for endotracheal intubation in an airway manikin with immobilized cervical spine by novice paramedics A randomized crossover manikin trial
    Gawlowski, Pawel
    Smereka, Jacek
    Madziala, Marcin
    Cohen, Barak
    Ruetzler, Kurt
    Szarpak, Lukasz
    MEDICINE, 2017, 96 (16)
  • [4] A randomised crossover trial comparing the Airtraq® NT, McGrath® MAC and Macintosh laryngoscopes for nasotracheal intubation of simulated easy and difficult airways in a manikin
    Angel Gomez-Rios, Manuel
    Pinegger, Stephan
    de Carrillo Mantilla, Maria
    Vizcaino, Lucia
    Barreto-Calvo, Purisima
    Paech, Michael J.
    Gomez-Rios, David
    Lopez-Calvino, Beatriz
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2016, 66 (03): : 289 - 297
  • [5] Comparison of Bullard and Airtraq laryngoscopes with conventional laryngoscopy in a manikin study of simulated difficult intubation
    Legrand, Maria A. -L.
    Steinmann, Daniel
    Priebe, Hans-Joachim
    Mols, Georg
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2012, 29 (07) : 343 - 350
  • [6] Comparison between intubation through ILMA and Airtraq, in different non-conventional patient positions: a manikin study
    Grosomanidis, V.
    Amaniti, E.
    Pourzitaki, Ch
    Fyntanidou, V.
    Mouratidis, K.
    Vasilakos, D.
    EMERGENCY MEDICINE JOURNAL, 2012, 29 (01) : 32 - 36
  • [7] Endotracheal intubation in patients with cervical spine immobilization - A comparison of Macintosh and Airtraq laryngoscopes
    Maharaj, Chrisen H.
    Buckley, Elma
    Harte, Brian H.
    Laffey, John G.
    ANESTHESIOLOGY, 2007, 107 (01) : 53 - 59
  • [8] Comparison of the airtraq® and truview® laryngoscopes to the macintosh laryngoscope for use by advanced paramedics in easy and simulated difficult intubation in manikins
    Nasim S.
    Maharaj C.H.
    Butt I.
    Malik M.A.
    O'Donnell J.
    Higgins B.D.
    Harte B.H.
    Laffey J.G.
    BMC Emergency Medicine, 9 (1)
  • [9] A comparison of the McGrath-MAC and Macintosh laryngoscopes for child tracheal intubation during resuscitation by paramedics. A randomized, crossover, manikin study
    Szarpak, Lukasz
    Truszewski, Zenon
    Czyzewski, Lukasz
    Gaszynski, Tomasz
    Rodriguez-Nunez, Antonio
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (08) : 1338 - 1341
  • [10] Intubation performance using different laryngoscopes while wearing chemical protective equipment: a manikin study
    Schroeder, H.
    Zoremba, N.
    Rossaint, R.
    Deusser, K.
    Stoppe, C.
    Coburn, M.
    Rieg, A.
    Schaelte, G.
    BMJ OPEN, 2016, 6 (03):