Comparable ultrasound measurements of ten anatomical specimens of infant hip joints by the methods of Graf and Terjesen

被引:6
作者
Falliner, A
Hahne, HJ
Hedderich, J
Brossmann, J
Hassenpflug, J
机构
[1] Univ Hosp, Clin Orthopaed Surg, Kiel, Germany
[2] Univ Hosp, Inst Med Informat & Stat, Kiel, Germany
[3] Dept Diagnost & Intervent Radiol, Rendsburg, Germany
关键词
acetabular inlet plane; infant hip; standard plane; ultrasound;
D O I
10.1080/02841850410003554
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To define which sonographic section planes relative to the acetabular inlet plane will produce analyzable images with the methods of Graf and Terjesen. Material and Methods: Anatomical specimens of infant hip joints were investigated in a water bath using the methods of Graf and Terjesen. Acetabular position was varied in defined increments with respect to the ultrasound beam. The alpha angles and the femoral head coverage (FHC) were measured. Results: To obtain images analyzable by the two methods, the ultrasound beam had to intersect with the acetabular inlet plane at defined angles. The acetabular notch had to be anteriorly rotated from the ultrasound beam plane by at least 20degrees. Beam entry within a 50degrees sector posterior to the perpendicular on the inlet plane resulted in analyzable images. The stepwise multiple linear regression analysis showed that alpha angles and FHC were much affected by the coronal-plane transducer tilt. Conclusions: The fact that caudal tilts of the transducer are associated with reduced alpha angles and FHC values should be kept in mind in clinical ultrasound investigations. It is recommended that the transducer should be put on the greater trochanter perpendicular to the transverse axis of the body.
引用
收藏
页码:227 / 235
页数:9
相关论文
共 16 条
[2]  
Graf R, 1997, ORTHOPADE, V26, P14
[3]  
GRAF R, 1999, Z ORTHOP S1, V137, pA1
[4]  
GRAF R, 1985, SONOGRAPHIE SAUGLING
[5]   Ultrasound and neonatal hip screening: The five-year results of a prospective study in high-risk babies [J].
Lewis, K ;
Jones, DA ;
Powell, N .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1999, 19 (06) :760-762
[6]  
MELZER C, 1994, ULTRASCHALL KLIN PRA, V8, P253
[7]   CORRELATION OF ANATOMY AND ULTRASONOGRAPHIC IMAGES IN THE INFANT HIP - AN EXPERIMENTAL CADAVER STUDY [J].
NICHOLS, GW ;
SCHWENTKER, EP ;
BOAL, DKB .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1986, 6 (04) :410-415
[8]   DEMONSTRATION OF THE NEONATAL HIP-JOINT IN THE ANATOMIC FRONTAL PLANE AND BY ULTRASONOGRAPHY [J].
PFEIL, J ;
ROHE, K ;
VONHAGENS, G .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1986, 124 (02) :188-191
[9]   Outcome of ultrasonographic hip abnormalities in clinically stable hips [J].
Sucato, DJ ;
Johnston, CE ;
Birch, JG ;
Herring, JA ;
Mack, P .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1999, 19 (06) :754-759
[10]  
TEOT L, 1990, REV CHIR ORTHOP, V76, P8