Management of small aortic annulus in the era of sutureless valves: A comparative study among different biological options

被引:42
作者
Ghoneim, Aly [1 ]
Bouhout, Ismail [1 ]
Demers, Philippe [1 ]
Mazine, Amine [1 ]
Francispillai, Mary [1 ]
El-Hamamsy, Ismail [1 ]
Carrier, Michel [1 ]
Lamarche, Yoan [1 ]
Bouchard, Denis [1 ]
机构
[1] Univ Montreal, Montreal Heart Inst, Dept Cardiovasc Surg, Montreal, PQ, Canada
关键词
aortic valve replacement; aortic annulus; stentless prostheses; sutureless prostheses; prothesis-patient mismatch; STENTLESS VALVES; REPLACEMENT; TRIFECTA; BIOPROSTHESES; FREESTYLE; TRANSCATHETER; PROSTHESIS; EXERCISE; STENOSIS;
D O I
10.1016/j.jtcvs.2016.06.058
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Aortic valve replacement ( AVR) in patients with a small aortic annulus is a challenging problem. The objective of this study was to compare 4 surgical approaches in terms of hemodynamics and perioperative outcomes. Methods: A retrospective single-center study included 351 consecutive patients with a small aortic annulus ( <= 21 mm) who underwent aortic valve surgery between January 2007 and December 2014. Surgical techniques included standard AVR in 259 ( 74%) patients, aortic root enlargement in 20 ( 6%), implantation of a stentless bioprosthesis in 23 ( 6%), and sutureless AVR in 49 ( 13%). Results: Three hundred and eleven ( 89%) patients were female. The mean Logistic EuroSCORE II varied significantly among the groups and ranged from 6.5% +/- 5.4% in the standard AVR group to 9.2% +/- 4.7% in the stentless group. Early mortality occurred in 26 ( 7%) patients. Patients in the stentless group had the lowest aortic valve mean gradients on predischarge transthoracic echocardiography ( 10.9 +/- 6.2 mm Hg; P <.001). In the stented group, the Trifecta prosthesis displayed the lowest postoperative mean transaortic gradient ( 10.3 +/- 3.6; P<. 001) with no severe prosthesis-patient mismatch. Postoperative gradients of the sutureless group were comparable with stented prostheses. Conclusions: In our study, stentless AVR and Trifecta bioprostheses had the best hemodynamic outcomes. The Perceval sutureless prosthesis provides reasonable hemodynamic performance and is a safe alternative.
引用
收藏
页码:1019 / 1028
页数:10
相关论文
共 26 条
[1]  
Akins CW, 2008, ANN THORAC SURG, V85, P1490, DOI [10.1016/j.athoracsur.2007.12.082, 10.1016/j.ejcts.2007.12.055]
[2]   Are stentless valves superior to modern stented valves? A prospective randomized trial [J].
Ali, A ;
Halstead, JC ;
Cafferty, F ;
Sharples, L ;
Rose, F ;
Coulden, R ;
Lee, E ;
Dunning, J ;
Argano, V ;
Tsui, S .
CIRCULATION, 2006, 114 :I535-I540
[3]  
[Anonymous], J THORAC CARDIOVASC
[4]  
[Anonymous], J THORAC CARDIOVASC
[5]   Long-Term Clinical Outcomes 15 Years After Aortic Valve Replacement With the Freestyle Stentless Aortic Bioprosthesis [J].
Bach, David S. ;
Kon, Neal D. .
ANNALS OF THORACIC SURGERY, 2014, 97 (02) :544-551
[6]   Impact of implant technique following freestyle stentless aortic valve replacement [J].
Bach, DS ;
Cartier, PC ;
Kon, ND ;
Johnson, KG ;
Deeb, GM ;
Doty, DB .
ANNALS OF THORACIC SURGERY, 2002, 74 (04) :1107-1113
[7]   The St Jude Medical Trifecta aortic pericardial valve: Results from a global, multicenter, prospective clinical study [J].
Bavaria, Joseph E. ;
Desai, Nimesh D. ;
Cheung, Anson ;
Petracek, Michael R. ;
Groh, Mark A. ;
Borger, Michael A. ;
Schaff, Hartzell V. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (02) :590-597
[8]   Stentless aortic valve reoperations: A surgical challenge [J].
Borger, Michael A. ;
Prasongsukarn, Kriengchai ;
Armstrong, Susan ;
Feindel, Christopher M. ;
David, Tirone E. .
ANNALS OF THORACIC SURGERY, 2007, 84 (03) :737-744
[9]   The Demise of the Stentless Valve [J].
Borger, Michael A. ;
Lehmann, Sven ;
Seeburger, Joerg ;
Mohr, Friedrich W. .
SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2012, 24 (01) :5-7
[10]   Early failures of Trifecta aortic bioprosthesis [J].
Campisi, Salvatore ;
Camilleri, Lionel ;
Innorta, Andrea ;
Azarnoush, Kasra .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (01) :E133-E134