Tests on various configurations of Coriolis mass flowmeters

被引:20
|
作者
Gupta, P
Srinivasan, K
Prabhu, SV [1 ]
机构
[1] Indian Inst Technol, Dept Mech Engn, Bombay 400076, Maharashtra, India
[2] Tata Consultancy Serv, Bombay, Maharashtra, India
[3] Indian Inst Technol, Dept Engn Mech, Madras, Tamil Nadu, India
关键词
Coriolis; mass flow rate; U-tube; S-tube; mass;
D O I
10.1016/j.measurement.2005.11.019
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Experiments have been conducted on various configurations of Coriolis mass flowmeters, such as U-tube, S-tube, L-tube, and stair shaped tubes, with water as the working fluid. The sensitivity of the flowmeter has been measured for a wide range of parameters like position of sensors, geometry, material properties, etc. The results of this study indicate that the measured phase shift is proportional to the mass flow rate. The slope ratio (theoretical to measured) is observed to be constant for the range of parameters studies for U-tube flowmeters. Sensor positions for maximum sensitivity have been identified for S-tube and L-tube configurations. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:296 / 307
页数:12
相关论文
共 50 条
  • [1] Mass flowmeters based on the Coriolis principle
    Yseboodt, M
    ZKG INTERNATIONAL, 2006, 59 (02): : 22 - +
  • [2] Pressure effects on Coriolis mass flowmeters
    Wang, Tao
    Hussain, Yousif
    FLOW MEASUREMENT AND INSTRUMENTATION, 2010, 21 (04) : 504 - 510
  • [3] Coriolis mass flowmeters overcome vibration
    Patten, T
    MEASUREMENTS & CONTROL, 1997, (184): : 141 - 146
  • [4] Performance evaluation of coriolis mass flowmeters
    Al-Khamis, MN
    Al-Nojaim, AA
    Al-Marhoun, MA
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2002, 124 (02): : 90 - 94
  • [5] Pushing Coriolis mass flowmeters to the limit
    Henry, M
    Clark, C
    Cheesewright, B
    COMPUTING & CONTROL ENGINEERING JOURNAL, 2003, 14 (03): : 24 - 28
  • [6] THE WEIGHT VECTOR THEORY OF CORIOLIS MASS FLOWMETERS
    HEMP, J
    FLOW MEASUREMENT AND INSTRUMENTATION, 1994, 5 (04) : 247 - 253
  • [7] CHOOSE THE RIGHT MATERIAL FOR CORIOLIS MASS FLOWMETERS
    CARPENTER, B
    CHEMICAL ENGINEERING PROGRESS, 1990, 86 (10) : 55 - 60
  • [8] Research on signal processing of coriolis mass flowmeters
    Xu, KJ
    Yu, CX
    Jiang, HK
    Su, JH
    Chen, RB
    Liu, JJ
    ICEMI'99: FOURTH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 1999, : 835 - 841
  • [9] EFFECT OF PULSATING FLOW ON CORIOLIS MASS FLOWMETERS
    VETTER, G
    NOTZON, S
    FLOW MEASUREMENT AND INSTRUMENTATION, 1994, 5 (04) : 263 - 273
  • [10] A novel control algorithm for coriolis mass flowmeters
    Schröder, T
    Kolahi, K
    Röck, H
    TECHNISCHES MESSEN, 2004, 71 (04): : 259 - 268