Intra-rater reliability of hallux flexor strength measures using the Nintendo Wii Balance Board

被引:7
作者
Quek, June [1 ,2 ]
Treleaven, Julia [1 ,2 ]
Brauer, Sandra G. [1 ,2 ]
O'Leary, Shaun [1 ,3 ]
Clark, Ross A. [4 ]
机构
[1] Univ Queensland, St Lucia, Qld 4072, Australia
[2] Singapore Gen Hosp, Dept Physiotherapy, Singapore 169608, Singapore
[3] Royal Brisbane & Womens Hosp, Herston, Qld 4029, Australia
[4] Australian Catholic Univ, Fac Hlth Sci, Sch Exercise Sci, Fitzroy, Vic 3065, Australia
基金
澳大利亚国家健康与医学研究理事会;
关键词
Nintendo Wii Balance Board; Hallux flexor strength; Intrinsic foot muscles; Intra-rater reliability; FOOT; COMMUNITY; DEFORMITY; PEOPLE; MOTION; FALLS; TOES; RISK;
D O I
10.1186/s13047-015-0104-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The purpose of this study was to investigate the intra-rater reliability of a new method in combination with the Nintendo Wii Balance Board (NWBB) to measure the strength of hallux flexor muscle. Methods: Thirty healthy individuals (age: 34.9 +/- 12.9 years, height: 170.4 +/- 10.5 cm, weight: 69.3 +/- 15.3 kg, female = 15) participated. Repeated testing was completed within 7 days. Participants performed strength testing in sitting using a wooden platform in combination with the NWBB. This new method was set up to selectively recruit an intrinsic muscle of the foot, specifically the flexor hallucis brevis muscle. Statistical analysis was performed using intra-class coefficients and ordinary least product analysis. To estimate measurement error, standard error of measurement (SEM), minimal detectable change (MDC) and percentage error were calculated. Results: Results indicate excellent intra-rater reliability (ICC = 0.982, CI = 0.96-0.99) with an absence of systematic bias. SEM, MDC and percentage error value were 0.5, 1.4 and 12 % respectively. Conclusions: This study demonstrates that a new method in combination with the NWBB application is reliable to measure hallux flexor strength and has potential to be used for future research and clinical application.
引用
收藏
页数:5
相关论文
共 24 条
[1]   Validity and reliability of the Nintendo Wii Balance Board for assessment of standing balance [J].
Clark, Ross A. ;
Bryant, Adam L. ;
Pua, Yonghao ;
McCrory, Paul ;
Bennell, Kim ;
Hunt, Michael .
GAIT & POSTURE, 2010, 31 (03) :307-310
[2]   Reliability of an inexpensive and portable dynamic weight bearing asymmetry assessment system incorporating dual Nintendo Wii Balance Boards [J].
Clark, Ross Allan ;
McGough, Rian ;
Paterson, Kade .
GAIT & POSTURE, 2011, 34 (02) :288-291
[3]  
Fleiss JL., 1986, The design and analysis of clinical experiments, V1st ed, P432
[4]   EVALUATION OF CLAW TOE DEFORMITY, WEAKNESS OF THE FOOT INTRINSICS, AND POSTEROMEDIAL SHIN PAIN [J].
GARTH, WP ;
MILLER, ST .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (06) :821-827
[5]   Effectiveness of a Wii balance board-based system (eBaViR) for balance rehabilitation: a pilot randomized clinical trial in patients with acquired brain injury [J].
Gil-Gomez, Jose-Antonio ;
Llorens, Roberto ;
Alcaniz, Mariano ;
Colomer, Carolina .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2011, 8
[6]   Gait variability and fall risk in community-living older adults: A 1-year prospective study [J].
Hausdorff, JM ;
Rios, DA ;
Edelberg, HK .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2001, 82 (08) :1050-1056
[7]  
Kobayashi R., 1999, Journal of Physical Therapy Science, V11, P31, DOI [DOI 10.1589/JPTS.11.31, 10.1589/jpts.11.31]
[8]   Muscle imbalance and reduced ankle joint motion in people with hammer toe deformity [J].
Kwon, O. Y. ;
Tuttle, L. J. ;
Johnson, J. E. ;
Mueller, M. J. .
CLINICAL BIOMECHANICS, 2009, 24 (08) :670-675
[9]   Predicting falls within the elderly community: comparison of postural sway, reaction time, the Berg balance scale and the Activities-specific Balance Confidence (ABC) scale for comparing fallers and non-fallers [J].
Lajoie, Y ;
Gallagher, SP .
ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2004, 38 (01) :11-26
[10]   Statistical techniques for comparing measurers and methods of measurement: A critical review [J].
Ludbrook, J .
CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2002, 29 (07) :527-536