Robust stereo vision and calibration methodology for accurate three-dimensional digital image correlation measurements on submerged objects

被引:43
作者
Ke, X. [1 ]
Sutton, M. A. [1 ]
Lessner, S. M. [2 ]
Yost, M. [2 ]
机构
[1] Univ S Carolina, Dept Mech Engn, Columbia, SC 29208 USA
[2] Univ S Carolina, Sch Med, Columbia, SC 29208 USA
基金
美国国家科学基金会;
关键词
stereo vision; interface refraction; optimization; three-dimensional digital image correlation; submerged object shape; deformation measurements;
D O I
10.1243/03093247JSA425
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The effect of optical refraction at an interface between optically dissimilar media is modelled in order to apply the principles of three-dimensional digital image correlation (DIC) to measure deformations on submerged objects accurately. Using an analytical formulation for refraction at an interface, a non-linear solution approach is developed to perform stereo calibration. The proposed method incorporates a simplified parametric representation for the orientation and position of an interface(s), accounting explicitly for the effects of refraction at all such interfaces in the path of each stereo camera. Separating the calibration process into two parts, a modified bundle adjustment process with an updated Levenburg-Marquardt (LM) non-linear optimization algorithm is employed to determine (a) intrinsic and extrinsic stereo camera parameters without interface refraction and (b) orientation and position of each planar interface. Detailed simulations demonstrate the efficiency, accuracy, and stability of the methodology when using multiple images of a grid pattern undergoing general rigid body motion, even in the presence of Gaussian noise in the sensor plane measurements, providing a robust framework for practical implementation of the methodology for submerged object measurements.
引用
收藏
页码:689 / 704
页数:16
相关论文
共 24 条
[1]   Underwater binocular imaging of aerial objects versus the position of eyes relative to the flat water surface [J].
Barta, AS ;
Horváth, G .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2003, 20 (12) :2370-2377
[2]  
Ferreira R, 2005, LECT NOTES COMPUT SC, V3522, P102
[3]  
FLANNERY BP, 1992, NUMERICAL RECEIPT C, P683
[4]   Holography for underwater inspection and measurement: An overview of current work [J].
Foster, E ;
Watson, J .
OPTICS AND LASER TECHNOLOGY, 1997, 29 (01) :17-23
[5]   Generalized camera calibration including fish-eye lenses [J].
Gennery, Donald B. .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 2006, 68 (03) :239-266
[6]   A multiaxial computer-controlled organ culture and biomechanical device for mouse carotid arteries [J].
Gleason, RL ;
Gray, SP ;
Wilson, E ;
Humphrey, JD .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (06) :787-795
[7]  
HECHT E, 1974, OPTICS, P62
[8]   Accurate three-dimensional metrology of underwater objects using replayed real images from in-line and off-axis holograms [J].
Hobson, PR ;
Watson, J .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1999, 10 (12) :1153-1161
[9]  
HORVATH G, 1991, B MATH BIOL, V53, P425, DOI 10.1016/S0092-8240(05)80396-9
[10]   UNDERWATER HOLOGRAMMETRY - ABERRATIONS IN THE REAL IMAGE OF AN UNDERWATER OBJECT WHEN REPLAYED IN AIR [J].
KILPATRICK, JM ;
WATSON, J .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1988, 21 (12) :1701-1705