The Vienna functional electrical stimulation system for restoration of walking functions in spastic paraplegia

被引:13
作者
Bijak, M
Mayr, W
Rakos, M
Hofer, C
Lanmüller, H
Rafolt, D
Reichel, M
Sauermann, S
Schmutterer, C
Unger, E
Russold, M
Kern, T
机构
[1] Univ Vienna, Dept Biomed Engn & Phys, A-1090 Vienna, Austria
[2] Otto Bock Austria, Vienna, Austria
[3] Wilhelminenspital Stadt Wien, Dept Phys Med & Rehabil, Vienna, Austria
关键词
functional electrical stimulation; lower extremities; spastic paraplegia; surface stimulator;
D O I
10.1046/j.1525-1594.2002.06935.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An eight-channel stimulation system, currently intended for stimulation of lower extremities, was developed and is introduced. The major development goals were easy handling, modularity to make the system easily adaptable for other functional electrical stimulation (FES) applications, and a wide stimulation parameter range for application-specific parameter optimization. For paraplegic stepping, the system worn by the patient consists of 2 four-channel stimulation modules, a central unit holding the battery and circuitry for power management and communication control, a wireless remote control unit, and a palmtop computer as the main control and input device. A software package for Microsoft Windows supports the design and optimization of stimulation sequences in the rehabilitation center. First tests with patients familiar with FES showed smoother movements during stepping and acceptable good handling. In combination with the PC software, the required stimulation sequences could be created in a very short time.
引用
收藏
页码:224 / 227
页数:4
相关论文
共 7 条
  • [1] Angeli T., 1999, MED BIOL ENG COMP S2, V37, P326
  • [2] Personal computer supported eight channel surface stimulator for paraplegic walking:: First results
    Bijak, M
    Hofer, C
    Lanmüller, H
    Mayr, W
    Sauermann, S
    Unger, E
    Kern, H
    [J]. ARTIFICIAL ORGANS, 1999, 23 (05) : 424 - 427
  • [3] BIJAK M, 2000, 3 INT C BIOEL P LJUB, P217
  • [4] Paraplegia: Prolonged closed-loop standing with implanted nucleus FES-22 stimulator and Andrews' foot-ankle orthosis
    Davis, R
    Houdayer, T
    Andrews, B
    Emmons, S
    Patrick, J
    [J]. STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1997, 69 (1-4) : 281 - 287
  • [5] HOLLE J, 1984, ORTHOPEDICS, V7, P1145, DOI 10.3928/0147-7447-19840701-09
  • [6] Kobetic R, 1999, IEEE Trans Rehabil Eng, V7, P390, DOI 10.1109/86.808942
  • [7] PROGRAMMED 6-CHANNEL ELECTRICAL STIMULATOR FOR COMPLEX STIMULATION OF LEG MUSCLES DURING WALKING
    STROJNIK, P
    KRALJ, A
    URSIC, I