Longitudinal and Horizontal Load Testing of Inflatable Penile Implant Cylinders of Two Manufacturers: An Ex Vivo Demonstration of Inflated Rigidity

被引:19
作者
Scovell, Jason M. [1 ,2 ]
Ge, Liehui [3 ]
Barrera, Enrique V. [2 ,4 ]
Wilson, Steven K. [5 ]
Carrion, Rafael E. [6 ]
Hakky, Tariq S. [6 ,7 ]
机构
[1] Baylor Coll Med, Dept Urol, Houston, TX 77030 USA
[2] Baylor Coll Med, Interdept Program Translat Biol & Mol Med, Houston, TX 77030 USA
[3] Rice Univ, Mat Sci & Nanoengn Dept, Houston, TX USA
[4] Tecnol Monterrey, Escuela Ingn & Cincias, Monterrey, Mexico
[5] Inst Urol Excellence, Indio, CA USA
[6] Univ S Florida, Dept Urol, 1 Tampa Gen Circle, Tampa, FL 33601 USA
[7] Adv Urol, Atlanta, GA USA
关键词
Erectile Dysfunction; Material Properties; Prosthesis; PROSTHESIS; EXPERIENCE; PLACEMENT; DEVICE;
D O I
10.1016/j.jsxm.2016.09.015
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Since the inception of the inflatable penile prosthesis, a new era has been ushered in for the management of erectile dysfunction. Despite multiple innovations to improve function and reliability, there are no current data comparing the biomechanical properties of these devices. Aim: To compare the resistance of the Coloplast Titan (Minneapolis, MN, USA) with that of the AMS 700 LGX (Minnetonka, MN, USA) penile prosthesis cylinders to longitudinal (penetration) and horizontal (gravity) forces. Methods: We compared two cylinder sizes from each company: the Coloplast Titan (18 and 22 cm) and the AMS 700 LGX (18 and 21 cm). To evaluate axial rigidity, which simulates forces during penetration, we performed a longitudinal load compression test to determine the load required to cause the cylinder to kink. To test horizontal rigidity, which simulates the horizontal forces exerted by gravity, we performed a modified cantilever test and measured the degrees of bend for each device. All devices were tested at 10, 15, and 20 PSI to simulate in vivo pressures. Main Outcome Measures: The main outcome measurement for the longitudinal load test (penetration) was the force required for the inflated cylinder to bend, thereby affecting its rigidity. The main outcome for the horizontal rigidity test (gravity) was the angle of displacement, in which a smaller angle represents a more horizontally rigid device. Results: Longitudinal column testing (penetration) demonstrated that less force was required for the AMS device to kink compared with the Coloplast implant across all three fill pressures tested. The Coloplast Titan also had a smaller angle of displacement at the modified cantilever test (gravity) compared with the AMS implant across all fill pressures. Conclusion: The Coloplast Titan demonstrated greater resistance to longitudinal (penetration) and horizontal (gravity) forces in this study. The AMS device was very sensitive to fill pressures. In contrast, the Coloplast Titan's ability to resist these forces was less dependent on the device fill pressure. Copyright (C) 2016, International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1750 / 1757
页数:8
相关论文
共 12 条
[1]   Long-Term Infection Outcomes After Original Antibiotic Impregnated Inflatable Penile Prosthesis Implants: Up to 7.7 Years of Followup [J].
Carson, Culley C., III ;
Mulcahy, John J. ;
Harsch, Manya R. .
JOURNAL OF UROLOGY, 2011, 185 (02) :614-618
[2]   Comparison between AMS 700™ CX and Coloplast™ Titan Inflatable Penile Prosthesis for Peyronie's Disease Treatment and Remodeling: Clinical Outcomes and Patient Satisfaction [J].
Chung, Eric ;
Solomon, Matthew ;
DeYoung, Ling ;
Brock, Gerald B. .
JOURNAL OF SEXUAL MEDICINE, 2013, 10 (11) :2855-2860
[3]   High Submuscular Placement of Urologic Prosthetic Balloons and Reservoirs: 2-Year Experience and Patient-reported Outcomes [J].
Chung, Paul H. ;
Morey, Allen F. ;
Tausch, Timothy J. ;
Simhan, Jay ;
Scott, J. Francis .
UROLOGY, 2014, 84 (06) :1540-1545
[4]  
Coloplast, 2012, TIT SER SOL
[5]   The Evolution of the Inflatable Penile Prosthetic Device and Surgical Innovations with Anatomical Considerations [J].
Hakky, Tariq S. ;
Wang, Run ;
Henry, Gerard D. .
CURRENT UROLOGY REPORTS, 2014, 15 (06)
[6]  
Henry GD, 2009, J SEX MED, V6, P675, DOI [10.1111/j.1743-6109.2008.01145.x, 10.1111/j.1743-6109.2008.01200.x]
[7]   Mechanical failure of the American Medical Systems Ultrex inflatable penile prosthesis: Before and after 1993 structural modification [J].
Milbank, AJ ;
Montague, DK ;
Angermeier, KW ;
Lakin, MM ;
Worley, SE .
JOURNAL OF UROLOGY, 2002, 167 (06) :2502-2506
[8]  
Mulcahy John J, 2016, Sex Med Rev, V4, P177, DOI 10.1016/j.sxmr.2015.11.003
[9]   INTRALUMINAL DEVICE PRESSURES IN 3-PIECE INFLATABLE PENILE PROSTHESES - THE PATHOPHYSIOLOGY OF MECHANICAL MALFUNCTION [J].
PESCATORI, ES ;
GOLDSTEIN, I .
JOURNAL OF UROLOGY, 1993, 149 (02) :295-300
[10]   Learning Penile Anatomy to Improve Function [J].
Reed-Maldonado, Amanda B. ;
Lue, Tom F. .
JOURNAL OF UROLOGY, 2016, 196 (03) :643-644