Eigenspace Beamformer Combined with Generalized Sidelobe Canceler and Filters for Generating Plane Wave Ultrasound Images

被引:0
作者
Neves, L. C. [1 ]
Maia, J. M. [1 ]
Zimbico, A. J. [2 ]
Gomes, D. F. [1 ]
Assef, A. A. [1 ]
Costa, E. T. [3 ]
机构
[1] Fed Univ Technol Parana UTFPR, Elect & Comp Engn CPGEI, Av Sete Setembro 3165, Curitiba, Parana, Brazil
[2] Eduardo Mondlane Univ UEM, Elect Engn Dept DEEL, Maputo, Mozambique
[3] Univ Estadual Campinas, UNICAMP, Biomed Engn Dept DEB FEEC, Campinas, Brazil
来源
XXVII BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2020 | 2022年
关键词
Ultrasound images; Generalized sidelobe canceler; Eigenspace beamformer; Plane wave; Adaptive filters;
D O I
10.1007/978-3-030-70601-2_246
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of plane waves allows images with higher frame rates compared to conventional modes. Some studies have shown that the use of the Eigenspace Beamformer technique associated with the Generalized Sidelobe Canceler (EBGSC) reduces the effects of interference and noise, minimizing sidelobes and providing images with higher contrast and resolution compared to the Delay and Sum (DAS) and the Minimum Variance (MV) methods. Filters can also be applied after image processing to reduce speckle signals present in ultrasound images such as the Wiener and Kuan filter. This work presents the implementation of the EBGSC method with Wiener and Kuan filters to improve the processing of plane wave ultrasound images. The EBGSC method combined with Wiener filter (EBGSC-W) showed an improvement in the contrast of 70% and 57.2% when compared to the DAS and GSC methods, respectively. The geometric distortion was evaluated using the parameter of the full width at half maximum (FWHM) and the EBGSC-W also obtained a reduction in lateral FWHM by 63% and 25% compared to the DAS and GSC methods, respectively, approaching to the actual value of the target size (0.1 mm). The EBGSC method with the Kuan filter (EBGSC-K) showed improvements in the lateral FWHM, however, it worsened the contrast, with loss of information.
引用
收藏
页码:1687 / 1692
页数:6
相关论文
共 17 条
  • [1] Aliabadi S, 2016, 2016 URSI ASIA-PACIFIC RADIO SCIENCE CONFERENCE (URSI AP-RASC), P1449, DOI 10.1109/URSIAP-RASC.2016.7601403
  • [2] [Anonymous], ULTRASOUND TOOLBOX
  • [3] APPLEBAUM SP, 1976, IEEE T ANTENN PROPAG, V24, P650, DOI 10.1109/TAP.1976.1141416
  • [4] Ultrafast Compound Doppler Imaging: Providing Full Blood Flow Characterization
    Bercoff, Jeremy
    Montaldo, Gabriel
    Loupas, Thanasis
    Savery, David
    Meziere, Fabien
    Fink, Mathias
    Tanter, Mickael
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (01) : 134 - 147
  • [5] HIGH-RESOLUTION FREQUENCY-WAVENUMBER SPECTRUM ANALYSIS
    CAPON, J
    [J]. PROCEEDINGS OF THE IEEE, 1969, 57 (08) : 1408 - &
  • [6] Jensen J. A., 1996, Medical & Biological Engineering & Computing, V34, P351
  • [7] CALCULATION OF PRESSURE FIELDS FROM ARBITRARILY SHAPED, APODIZED, AND EXCITED ULTRASOUND TRANSDUCERS
    JENSEN, JA
    SVENDSEN, NB
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (02) : 262 - 267
  • [8] ADAPTIVE RESTORATION OF IMAGES WITH SPECKLE
    KUAN, DT
    SAWCHUK, AA
    STRAND, TC
    CHAVEL, P
    [J]. IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1987, 35 (03): : 373 - 383
  • [9] Eigenspace-Based Generalized Sidelobe Canceler Beamforming Applied to Medical Ultrasound Imaging
    Li, Jiake
    Chen, Xiaodong
    Wang, Yi
    Li, Wei
    Yu, Daoyin
    [J]. SENSORS, 2016, 16 (08)
  • [10] Plane-Wave Imaging Challenge in Medical Ultrasound
    Liebgott, H.
    Rodriguez-Molares, A.
    Cervenansky, F.
    Jensen, J. A.
    Bernard, O.
    [J]. 2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,