Predictors of atrial fibrillation recurrence after atrial fibrillation ablation with cryoballoon

被引:22
|
作者
Evranos, Banu [1 ]
Aytemir, Kudret [1 ]
Oto, Ali [1 ]
Okutucu, Sercan [1 ]
Karakulak, Ugur [1 ]
Sahiner, Levent [1 ]
Kaya, Baris [1 ]
Kabakci, Giray [1 ]
机构
[1] Hacettepe Univ, Dept Cardiol, TR-06100 Ankara, Turkey
关键词
cryoballoon ablation; intraleft AEMD; early atrial fibrillation recurrence; PULMONARY VEIN ISOLATION; RADIOFREQUENCY CATHETER ABLATION; TISSUE DOPPLER-ECHOCARDIOGRAPHY; EXPERT CONSENSUS STATEMENT; P-WAVE DISPERSION; FOLLOW-UP; SURGICAL ABLATION; ANTRUM ISOLATION; CONDUCTION TIME; DELAY;
D O I
10.5603/CJ.2013.0075
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Catheter ablation of atrial fibrillation is recommended for patients with symptomatic paroxysmal atrial fibrillation (PAF) despite anti-arrhythmic drugs (AADs). Radiofrequency ablation is widely accepted as an effective treatment for PAF. Cryoenergy by cryoballoon technique is an alternative to radiofrequency (RF) ablation. Cryoballoon ablation is safe, and has a similar success rate in comparison to RF ablation. AF recurrence with cryoballoon ablation is roughly 30%. The aim of this study is to determine the predictors of AF recurrence after cryoballoon ablation. Methods and Results: Sixty one patients with symptomatic PAF despite AADs without structural heart disease were included. Cryoballoon ablation was performed in 60 patients (36 males, mean age: 54.6 +/- 10.7, mean left atrium size: 3.74 +/- 0.39 mm). Transthoracic echocardiography including tissue Doppler imaging was performed in all subjects during sinus rhythm at baseline and after the ablation. Intra-atrial and inter-atrial electromechanical delays, and PA-lateral were measured. All patients were scheduled for 24 h Holter recording at baseline and at 3, 6, 9 months follow-up. Venous samples were collected to measure CK-MB, Troponin-T (TnT), erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) levels at baseline and 24 h after ablation. Median follow up was 10 (8-12) months. Forty eight (80%) patients were in sinus rhythm during the follow up. In receiver operating curve (ROC) analysis, intraleft atrial electromechanical delay and PA-lateral achieve an area under the curve (AUC) 0.97 (p < 0.001) and 0.69 (p < 0.001) for the ability to predict AF recurrence. A cut-off value for baseline intraleft atrial electromechanical delay of 29.5 ms predicted AF recurrence with sensitivity of 85% and specifity of 98%. A cut-off value for PA-lateral of 125 ms predicted AF recurrence with sensitivity of 80% and specifity of 90%. In ROC analysis, age achieves an AUC 0.822 (p = 0.006) for the ability to predict AF recurrence. A cut-off value for age of 64 predicted AF recurrence with sensitivity of 71% and specifity of 90%. Early recurrence of AF (HR = 60, 95% CI 18.61-417.86, p < 0.001) predicted also late recurrence of AF. Conclusions: The increase in AF recurrence by increased intraleft atrial electromechanical delay, PA-lateral and older age show the importance of substrate in AF mechanism. Early recurrence was the strongest predictor of late recurrence of AF; therefore, existence of blanking period for cryoballoon ablation should be questioned.
引用
收藏
页码:294 / 303
页数:10
相关论文
共 50 条
  • [1] Predictors of atrial fibrillation recurrence after cryoballoon ablation
    Aksu, Tolga
    Baysal, Erkan
    Guler, Tuemr Erdem
    Golcuk, Sukriye Ebru
    Erden, Ismail
    Ozcan, Kazim Serhan
    JOURNAL OF BLOOD MEDICINE, 2015, 6 : 211 - 217
  • [2] Patient characteristics as predictors of recurrence of atrial fibrillation following cryoballoon ablation
    Bavishi, Aakash A.
    Kaplan, Rachel M.
    Peigh, Graham
    Diaz, Celso L.
    Baman, Jayson R.
    Trivedi, Amar
    Wasserlauf, Jeremiah
    Shen, Mark J.
    Sattayaprasert, Prasongchai
    Chicos, Alexandru B.
    Kim, Susan
    Verma, Nishant
    Arora, Rishi
    Lin, Albert
    Knight, Bradley P.
    Passman, Rod S.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (06): : 694 - 704
  • [3] Efficacy of Cryoballoon Ablation for Atrial Fibrillation and Recurrence Predictors in an Asian Cohort
    Wu, Shang-Ju
    Li, Cheng-Hung
    Weng, Chi-Jen
    Lin, Jiunn-Cherng
    Chien, Yu-Shan
    Chen, Yi-Huei
    Lin, Ching-Heng
    Hsieh, Yu-Cheng
    Huang, Jin-Long
    Lo, Li-Wei
    Lin, Yenn-Jiang
    Chen, Shih-Ann
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (05):
  • [4] Risk factors for atrial fibrillation recurrence after cryoballoon catheter ablation in patients with paroxysmal atrial fibrillation
    Zhou, Jin
    Xu, Jing
    Sun, Shan
    Cheng, Aijuan
    Li, Peng
    Ding, Jun
    Yang, Peigen
    Zhang, Zhiyuan
    Fang, Tao
    Yan, Yingchuan
    Cong, Hongliang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (10): : 11205 - 11210
  • [5] Predictors of freedom from atrial arrhythmia recurrence after cryoballoon ablation for persistent atrial fibrillation: A multicenter study
    Reissmann, Bruno
    Plenge, Tobias
    Heeger, Christian-Hendrik
    Schlueter, Michael
    Wohlmuth, Peter
    Fink, Thomas
    Rottner, Laura
    Tilz, Roland Richard
    Mathew, Shibu
    Lemes, Christine
    Maurer, Tilman
    Lueker, Jakob
    Sultan, Arian
    Bellmann, Barbara
    Goldmann, Britta
    Ouyang, Feifan
    Kuck, Karl-Heinz
    Metzner, Andreas
    Steven, Daniel
    Rillig, Andreas
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (09) : 1436 - 1442
  • [6] Predictors of recurrence after atrial fibrillation catheter ablation
    Sener, Yusuf Ziya
    Oksul, Metin
    Akkaya, Fatih
    ACTA CARDIOLOGICA, 2020, 75 (08) : 810 - 810
  • [7] Is the time of atrial fibrillation recurrence after cryoballoon ablation of paroxysmal atrial fibrillation influenced by the pattern of PV reconnections?
    Marcus Wieczorek
    Kiarash Sassani
    Reinhard Hoeltgen
    Journal of Interventional Cardiac Electrophysiology, 2021, 60 : 321 - 327
  • [8] Common Atrial Fibrillation Susceptibility Alleles - Predictors for Atrial Fibrillation Recurrence after Catheter Ablation?
    Ueberham, Laura
    Husser, Daniela
    Arya, Arash
    Adams, Volker
    Hindricks, Gerhard
    Bollmann, Andreas
    CIRCULATION, 2012, 126 (21)
  • [9] Impact of very early recurrence of atrial fibrillation after cryoballoon ablation
    Ukita, Kohei
    Egami, Yasuyuki
    Kawanami, Shodai
    Sugae, Hiroki
    Kawamura, Akito
    Nakamura, Hitoshi
    Yasumoto, Koji
    Tsuda, Masaki
    Okamoto, Naotaka
    Matsunaga-Lee, Yasuharu
    Yano, Masamichi
    Nishino, Masami
    Tanouchi, Jun
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2022, 45 (11): : 1323 - 1329
  • [10] Is the time of atrial fibrillation recurrence after cryoballoon ablation of paroxysmal atrial fibrillation influenced by the pattern of PV reconnections?
    Wieczorek, Marcus
    Sassani, Kiarash
    Hoeltgen, Reinhard
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 60 (02) : 321 - 327