Fast HPLC-DAD quantification procedure for selected sulfonamids, metronidazole and chloramphenicol in wastewaters using second-order calibration based on MCR-ALS

被引:43
作者
Vosough, Maryam [1 ]
Esfahani, Hadi Mashhadiabbas [1 ]
机构
[1] Chem & Chem Engn Res Ctr Iran, Tehran, Iran
关键词
Antibiotics; Liquid chromatography-diode array detection; Second-order calibration; Solid-phase extraction; Wastewater; ENVIRONMENTAL RISK-ASSESSMENT; SOLID-PHASE EXTRACTION; WATER TREATMENT PLANTS; WASTE-WATER; TETRACYCLINE ANTIBIOTICS; HOSPITAL EFFLUENT; MASS-SPECTROMETRY; SURFACE WATERS; RESOLUTION; METHODOLOGIES;
D O I
10.1016/j.talanta.2013.03.049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present work focuses on the application of multivariate curve resolution-alternating least squares (MCR-ALS) for analysis of five important antibiotics (sulfamethoxazole, metronidazole, chloramphenicol, sulfadizine and sulfamerazine) in highly complex wastewater samples, using solid phase extraction (SPE)-high performance liquid chromatography with diode-array detection (HPLC-DAD) on a short column, regarding the fast elution methodology. The samples were pre-concentrated on Bond Elut-ENV cartridges and separated on an ODS column (7 cm) in less than 4 min using an isocratic mode of elution with methanol-water (55:45, v/v) at pH=3.2. Due to the matrix interferences and the resulting sensitivity changes, a strategy implementing standard addition calibration in combination with MCR/ALS algorithm was applied. In this paper, the signal corresponding to background contribution was considered as a systematic part of the model during MCR/ALS data processing, so the background correction step was not necessary. The qualitative and quantitative results showed that the application of MCR/ALS algorithm in the traditional chromatographic method was appropriately able to resolve highly drifted background constituents as well as heavily overlapped peaks among the analytes and also between the analytes and the matrix interferences. Recoveries were ranged from 69.6% to 120.3% with relative standard deviations of less than or equal to 11.0% and showed the acceptable performance of the method. Additionally, statistical t-test as well as computed elliptical joint confidence region (EJCR) confirmed the accuracy of the proposed method and indicated the absence of both constant and proportional errors in the predicted concentrations. The results well explained that the second-order advantage for analytes was achieved in samples containing one or more uncalibrated components, which strongly related to wastewater samples. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:68 / 75
页数:8
相关论文
共 38 条
  • [1] ChroMATHography: Solving Chromatographic Issues with Mathematical Models and Intuitive Graphics
    Amigo, Jose Manuel
    Skov, Thomas
    Bro, Rasmus
    [J]. CHEMICAL REVIEWS, 2010, 110 (08) : 4582 - 4605
  • [2] Comparison of the occurrence of antibiotics in four full-scale wastewater treatment plants with varying designs and operations
    Batt, Angela L.
    Kim, Sungpyo
    Aga, Diana S.
    [J]. CHEMOSPHERE, 2007, 68 (03) : 428 - 435
  • [3] THEORY OF ANALYTICAL-CHEMISTRY
    BOOKSH, KS
    KOWALSKI, BR
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (15) : A782 - A791
  • [4] Occurrence of antibiotics in hospital, residential, and dairy, effluent, municipal wastewater, and the Rio Grande in New Mexico
    Brown, Kathryn D.
    Kulis, Jerzy
    Thomson, Bruce
    Chapman, Timothy H.
    Mawhinney, Douglas B.
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2006, 366 (2-3) : 772 - 783
  • [5] Chitnis V, 2000, CURR SCI INDIA, V79, P989
  • [6] Factor analysis of hyphenated chromatographic data - Exploration, resolution and quantification of multicomponent systems
    de Juan, Anna
    Tauler, Roma
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1158 (1-2) : 184 - 195
  • [7] Solving matrix-effects exploiting the second order advantage in the resolution and determination of eight tetracycline antibiotics in effluent wastewater by modelling liquid chromatography data with multivariate curve resolution-alternating least squares and unfolded-partial least squares followed by residual bilinearization algorithms I.: Effect of signal pre-treatment
    De Zan, M. M.
    Garcia, M. D. Gil
    Culzoni, M. J.
    Siano, R. G.
    Goicoechea, H. C.
    Galera, M. Martinez
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1179 (02) : 106 - 114
  • [8] LC-MS2 trace analysis of antimicrobials in water, sediment and soil
    Díaz-Cruz, MS
    Barceló, D
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (07) : 645 - 657
  • [9] Fast and compact smoothing on large multidimensional grids
    Eilers, PHC
    Currie, ID
    Durbán, M
    [J]. COMPUTATIONAL STATISTICS & DATA ANALYSIS, 2006, 50 (01) : 61 - 76
  • [10] Chemometric tools improving the determination of anti-inflammatory and antiepileptic drugs in river and wastewater by solid-phase microextraction and liquid chromatography diode array detection
    Gil Garcia, M. D.
    Canada Canada, F.
    Culzoni, M. J.
    Vera-Candioti, L.
    Siano, G. G.
    Goicoechea, H. C.
    Martinez Galeral, M.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (29) : 5489 - 5496