Electrogenerated chemiluminescence detection in reversed-phase liquid chromatography

被引:16
作者
Forry, SP [1 ]
Wightman, RM [1 ]
机构
[1] Univ N Carolina, Dept Chem, Chapel Hill, NC 27599 USA
关键词
D O I
10.1021/ac0110193
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrogenerated chemiluminescence (ECL) has been developed as a detection method for liquid chromatography. The radical cation of tri-p-tolylamine (TPTA) is used as a common electron acceptor for the electrogenerated radical anions of a variety of organic analytes. ECL is accomplished with a high-frequency potential pulse program applied to a microelectrode immersed in the column eluent. ECL detection is demonstrated with reversed-phase liquid chromatography. Selectivity at the ECL detector is shown to be tunable based on differing electrochemical conditions and excited-state energetics. Low minimum detection limits in ECL are attributed to the dependence on the photon detector shot noise, allowing a limit of detection of 0.14 nM for perylene in the presence of 0.1 mM TPTA, A derivatization agent useful for ECL detection is demonstrated by the use of naphthalene-2,3-dicarboxaldehyde. This reagent, which does not itself result in ECL, forms ECL candidates following reaction with primary amines.
引用
收藏
页码:528 / 532
页数:5
相关论文
共 25 条
[1]   ELECTROCHEMILUMINESCENCE AS A DETECTION TECHNIQUE FOR REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. PRELIMINARY EXPERIMENTS [J].
BLATCHFORD, C ;
MALCOLMELAWES, DJ .
JOURNAL OF CHROMATOGRAPHY, 1985, 321 (01) :227-234
[2]   ELECTROCHEMILUMINESCENCE AS A DETECTION TECHNIQUE FOR REVERSED PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .2. LOW-FREQUENCY AC ELECTROCHEMILUMINESCENCE [J].
BLATCHFORD, C ;
HUMPHREYS, E ;
MALCOLMELAWES, DJ .
JOURNAL OF CHROMATOGRAPHY, 1985, 329 (02) :281-284
[3]   NEW DERIVATIZING AGENTS FOR AMINO-ACIDS AND PEPTIDES .1. FACILE SYNTHESIS OF N-SUBSTITUTED 1-CYANOBENZ[F]ISOINDOLES AND THEIR SPECTROSCOPIC PROPERTIES [J].
CARLSON, RG ;
SRINIVASACHAR, K ;
GIVENS, RS ;
MATUSZEWSKI, BK .
JOURNAL OF ORGANIC CHEMISTRY, 1986, 51 (21) :3978-3983
[4]   HIGH-FREQUENCY GENERATION OF ELECTROCHEMILUMINESCENCE AT MICROELECTRODES [J].
COLLINSON, MM ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2576-2582
[5]   OBSERVATION OF INDIVIDUAL CHEMICAL REACTIONS IN SOLUTION [J].
COLLINSON, MM ;
WIGHTMAN, RM .
SCIENCE, 1995, 268 (5219) :1883-1885
[6]   EVALUATION OF ION-ANNIHILATION REACTION-KINETICS USING HIGH-FREQUENCY GENERATION OF ELECTROCHEMILUMINESCENCE [J].
COLLINSON, MM ;
WIGHTMAN, RM ;
PASTORE, P .
JOURNAL OF PHYSICAL CHEMISTRY, 1994, 98 (46) :11942-11947
[7]   SOME OBSERVATIONS ON ANALYTICAL USEFULNESS OF ELECTROCHEMILUMINESCENCE FOR DETERMINATION OF MICROGRAM AMOUNTS OF AROMATIC HYDROCARBONS [J].
FLEET, B ;
KELIHER, PN ;
KIRKBRIGHT, GF ;
PICKFORD, CJ .
ANALYST, 1969, 94 (1123) :847-+
[8]   Electrogenerated chemiluminescence from derivatives of aluminum quinolate and quinacridones: Cross-reactions with triarylamines lead to singlet emission through triplet-triplet annihilation pathways [J].
Gross, EM ;
Anderson, JD ;
Slaterbeck, AF ;
Thayumanavan, S ;
Barlow, S ;
Zhang, Y ;
Marder, SR ;
Hall, HK ;
Nabor, MF ;
Wang, JF ;
Mash, EA ;
Armstrong, NR ;
Wightman, RM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2000, 122 (20) :4972-4979
[9]   ELECTROCHEMILUMINESCENCE AS A DETECTION TECHNIQUE FOR REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .3. A HIGH-PERFORMANCE FLOW CELL [J].
HILL, E ;
HUMPHREYS, E ;
MALCOLMELAWES, DJ .
JOURNAL OF CHROMATOGRAPHY, 1986, 370 (03) :427-437
[10]   ELECTROCHEMILUMINESCENCE AS A DETECTION TECHNIQUE FOR REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .4. DETECTION OF FLUORESCENT DERIVATIVES [J].
HILL, E ;
HUMPHREYS, E ;
MALCOLMELAWES, DJ .