Analysis of solvent vapors in breath and ambient air with a surface acoustic wave sensor array

被引:33
作者
Groves, WA
Zellers, ET
机构
[1] Univ Michigan, Dept Environm Hlth Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
关键词
volatile organic compounds; breath analysis; surface acoustic wave sensor; biological monitoring; sensor array;
D O I
10.1016/S0003-4878(01)00020-5
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
This article describes the development and evaluation of a small prototype instrument employing an array of four polymer-coated surface acoustic wave (SAW) sensors for rapid analysis of organic solvent vapors in exhaled breath and ambient air. A thermally desorbed adsorbent preconcentrator within the instrument is used to increase sensitivity and compensate for background water vapor. Calibrations were performed for breath and dry nitrogen samples in Tedlar bags spiked with 16 individual solvents and selected binary mixtures. Responses were linear over the 50- to 400-fold concentration ranges examined and mixture responses were additive. The resulting library of vapor calibration response patterns was used with extended disjoint principal components regression and a probabilistic artificial neural network to develop vapor-recognition algorithms. In a subsequent analysis of an independent data set all individual vapors and most binary mixture components were correctly identified and were quantified to within 25% of their actual concentrations. Limits of detection for a 0.25 l. sample collected over a 2.5-min period were <0.3xTLV for 14 of the 16 vapors based on the criterion that all four sensors show a detectable response. Results demonstrate the feasibility of this technology for workplace analysis of breath and ambient air. (C) 2001 British Occupational Hygiene Society. Published by Elsevier Science Ltd. All rights reserved
引用
收藏
页码:609 / 623
页数:15
相关论文
共 57 条
[1]  
*ACGIH WORLDW, 1996, AM C GOV IND HYG TLV
[2]  
[Anonymous], ANAL CHEM
[3]  
Ballantine D.S., 1997, ACOUSTIC WAVE SENSOR
[4]   BREATH ANALYSIS BY API MS - HUMAN EXPOSURE TO VOLATILE ORGANIC-SOLVENTS [J].
BENOIT, FM ;
DAVIDSON, WR ;
LOVETT, AM ;
NACSON, S ;
NGO, A .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1985, 55 (02) :113-120
[5]   Vapor recognition with an integrated array of polymer-coated flexural plate wave sensors [J].
Cai, QY ;
Park, J ;
Heldsinger, D ;
Hsieh, MD ;
Zellers, ET .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 62 (02) :121-130
[6]   CHEMOMETRIC ANALYSIS OF MULTISENSOR ARRAYS [J].
CAREY, WP ;
BEEBE, KR ;
SANCHEZ, E ;
GELADI, P ;
KOWALSKI, BR .
SENSORS AND ACTUATORS, 1986, 9 (03) :223-234
[7]   MULTICOMPONENT ANALYSIS USING AN ARRAY OF PIEZOELECTRIC CRYSTAL SENSORS [J].
CAREY, WP ;
BEEBE, KR ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1987, 59 (11) :1529-1534
[8]   CHEMICAL PIEZOELECTRIC SENSOR AND SENSOR ARRAY CHARACTERIZATION [J].
CAREY, WP ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1986, 58 (14) :3077-3084
[9]  
*CDCP NAT I OCC SA, 1997, NIOSH POCK GUID CHEM
[10]  
*DHHS, 1994, NIOSH MANUAL ANAL ME