The effect of seed orientation deviations on the quality of 125I prostate implants

被引:24
作者
Corbett, JF [1 ]
Jezioranski, JJ
Crook, J
Tran, T
Yeung, IWT
机构
[1] Princess Margaret Hosp, Dept Radiat Phys, Toronto, ON M4X 1K9, Canada
[2] Princess Margaret Hosp, Dept Radiat Oncol, Toronto, ON M4X 1K9, Canada
[3] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5G 2M9, Canada
关键词
D O I
10.1088/0031-9155/46/11/303
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We quantified the effect of seed orientation deviations on five prostate seed implant cases at our institution. While keeping their positions fixed, the iodine-125 seeds were assigned orientations sampled from a realistic probability distribution derived from the post-implant radiographs of ten patients. Dose distributions were calculated with both a model that explicitly includes anisotropy (TG43 anisotropy function) and a point source model (TG43 anisotropy factor). Orientation deviations had only a small influence on prostate dose-volume histograms: the 95% confidence intervals on the volumes receiving 100%, 150% and 200% dose were at most +/-0.8%, +/-1.1% and +/-0.6% of the prostate volume, respectively. The dose-volume histograms of anisotropic seed distributions were marginally better than those with isotropic point-source seeds. Anisotropy caused a displacement of cold spots (regions receiving <100% of the prescribed dose) in <1% of the prostate volume. Our results indicate no net benefit to prostate dosimetry in using more isotropic seeds. Furthermore, we propose a new 'weighted anisotropy function' to better account for the effects of anisotropy when seed orientation is unknown. Conceptually, the TG43 anisotropy factor described in AAPM TG43 averages the effect of anisotropy over all solid angles, with the implicit assumption that all seed orientations are equally probable. In prostate implants, however, seeds are preferentially oriented parallel to the needle axis. The proposed weighted anisotropy function incorporates this non-uniform probability.
引用
收藏
页码:2785 / 2800
页数:16
相关论文
共 22 条
[21]   Edema associated with I-125 or Pd-103 prostate brachytherapy and its impact on post-implant dosimetry: An analysis based on serial CT acquisition [J].
Waterman, FM ;
Yue, N ;
Corn, BW ;
Dicker, AP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (05) :1069-1077
[22]   Permanent prostate seed implant brachytherapy: Report of the American Association of Physicists in Medicine Task Group No. 64 [J].
Yu, Y ;
Anderson, LL ;
Li, ZF ;
Mellenberg, DE ;
Nath, R ;
Schell, MC ;
Waterman, FM ;
Wu, A ;
Blasko, JC .
MEDICAL PHYSICS, 1999, 26 (10) :2054-2076