Subretinal Implantation of Electrospun, Short Nanowire, and Smooth Poly(ε-caprolactone) Scaffolds to the Subretinal Space of Porcine Eyes

被引:29
作者
Christiansen, A. T. [1 ]
Tao, S. L. [2 ]
Smith, M. [3 ]
Wnek, G. E. [4 ]
Prause, J. U. [5 ]
Young, M. J. [6 ]
Klassen, H. [7 ,8 ]
Kaplan, H. J. [9 ]
la Cour, M. [1 ]
Kiilgaard, J. F. [1 ]
机构
[1] Copenhagen Univ Hosp, Glostrup Hosp, Dept Ophthalmol, DK-2600 Glostrup, Denmark
[2] CooperVision Inc, Adv Dev Ctr, Pleasanton, CA 94588 USA
[3] NuVent Solut Inc, Valley View, OH 44125 USA
[4] Case Western Reserve Univ, Cleveland, OH 44106 USA
[5] Univ Copenhagen, Eye Pathol Inst, DK-2100 Copenhagen, Denmark
[6] Harvard Univ, Sch Med, Dept Ophthalmol, Schepens Eye Res Inst, Boston, MA 02114 USA
[7] Univ Calif Irvine, Gavin Herbert Eye Inst, Irvine, CA 92697 USA
[8] Univ Calif Irvine, Stem Cell Res Ctr, Irvine, CA 92697 USA
[9] Univ Louisville, Dept Ophthalmol & Visual Sci, Kentucky Lions Eye Ctr, Louisville, KY 40208 USA
关键词
INTEGRATION; DIFFERENTIATION; TRANSPLANTATION;
D O I
10.1155/2012/454295
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Biodegradable scaffolds play an important adjunct role in transplantation of retinal progenitor cells (RPCs) to the subretinal space. Poly(epsilon-Caprolactone) (PCL) scaffolds with different modifications were subretinally implanted in 28 porcine eyes and evaluated by multifocal electroretinography (mfERG) and histology after 6 weeks of observation. PCL Short Nanowire, PCL Electrospun, and PCL Smooth scaffolds were well tolerated in the subretinal space in pigs and caused no inflammation and limited tissue disruption. PCL Short Nanowire had an average rate of preserved overlying outer retina 17% higher than PCL Electrospun and 25% higher than PCL Smooth. Furthermore, PCL Short Nanowire was found to have the most suitable degree of stiffness for surgical delivery to the subretinal space. The membrane-induced photoreceptor damage could be shown on mfERG, but the reductions in P1 amplitude were only significant for the PCL Smooth. We conclude that of the tested scaffolds, PCL Short Nanowire is the best candidate for subretinal implantation.
引用
收藏
页数:8
相关论文
共 23 条
[1]  
Cai S., J BIOMATERI IN PRESS
[2]   Electrospun chitosan-graft-poly (ε-caprolactone)/poly (ε-caprolactone) nanofibrous scaffolds for retinal tissue engineering [J].
Chen, Honglin ;
Fan, Xianqun ;
Xia, Jing ;
Chen, Ping ;
Zhou, Xiaojian ;
Huang, Jin ;
Yu, Jiahui ;
Gu, Ping .
INTERNATIONAL JOURNAL OF NANOMEDICINE, 2011, 6 :453-461
[3]  
Christiansen AT, 2012, STEM CELLS INT, V2012
[4]   Electrophysiological Consequences of Experimental Branch Retinal Vein Occlusion in Pigs and the Effect of Dorzolamide [J].
Ejstrup, Rasmus ;
Scherfig, Erik ;
la Cour, Morten .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (02) :952-958
[5]   Differential degradation rates in vivo and in vitro of biocompatible poly(lactic acid) and poly(glycolic acid) homo- and co-polymers for a polymeric drug-delivery microchip [J].
Grayson, ACR ;
Voskerician, G ;
Lynn, A ;
Anderson, JM ;
Cima, MJ ;
Langer, R .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2004, 15 (10) :1281-1304
[6]   Brightness, contrast, and color balance of digital versus film retinal images in the age-related eye disease study 2 [J].
Hubbard, Larry D. ;
Danis, Ronald P. ;
Neider, Michael W. ;
Thayer, Dennis W. ;
Wabers, Hugh D. ;
White, James K. ;
Pugliese, Anthony J. ;
Pugliese, Michael F. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (08) :3269-3282
[7]   A tissue-engineered approach towards retinal repair: Scaffolds for cell transplantation to the subretinal space [J].
Hynes, Sara Royce ;
Lavik, Erin B. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (06) :763-778
[8]   A new animal model of choroidal neovascularization [J].
Kiilgaard, JF ;
Andersen, MVN ;
Wiencke, AK ;
Scherfig, E ;
la Cour, M ;
Tezel, TH ;
Prause, JU .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2005, 83 (06) :697-704
[9]   Stem cells in a new light [J].
Klassen, Henry ;
Reubinoff, Benjamin .
NATURE BIOTECHNOLOGY, 2008, 26 (02) :187-188
[10]   Functional implications of short-term retinal detachment in porcine eyes: study by multifocal electroretinography [J].
Kyhn, Maria Voss ;
Kiilgaard, Jens F. ;
Lopez, Ana Garcia ;
Scherfig, Erik ;
Prause, Jan U. ;
la Cour, Morten .
ACTA OPHTHALMOLOGICA, 2008, 86 (01) :18-25