The Effects of Cortical Bone Thickness and Trabecular Bone Strength on Noninvasive Measures of the Implant Primary Stability Using Synthetic Bone Models

被引:57
|
作者
Hsu, Jui-Ting [1 ]
Fuh, Lih-Jyh [1 ]
Tu, Ming-Gene [1 ]
Li, Yu-Fen [2 ,3 ]
Chen, Kuan-Ting [2 ]
Huang, Heng-Li [1 ]
机构
[1] China Med Univ, Sch Dent, Taichung 40402, Taiwan
[2] China Med Univ, Ctr Biostat, Taichung 40402, Taiwan
[3] China Med Univ, Grad Inst Biostat, Taichung 40402, Taiwan
关键词
cortical bone thickness; implant primary stability; insertion torque; periotest; resonance frequency analysis; strength of trabecular bone; RESONANCE FREQUENCY-ANALYSIS; DENTAL IMPLANTS; CANCELLOUS BONE; FINITE-ELEMENT; HUMAN CADAVER; OSSEOINTEGRATION; DENSITY; AUGMENTATION; OSTEOPOROSIS; SIMULATION;
D O I
10.1111/j.1708-8208.2011.00349.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study investigated how the primary stability of a dental implant as measured by the insertion torque value (ITV), Periotest value (PTV), and implant stability quotient (ISQ) is affected by varying thicknesses of cortical bone and strengths of trabecular bone using synthetic bone models. Materials and Methods: Four synthetic cortical shells (with thicknesses of 0, 1, 2, and 3mm) were attached to four cellular rigid polyurethane foams (with elastic moduli of 137, 47.5, 23, and 12.4MPa) and one open-cell rigid polyurethane foam which mimic the osteoporotic bone (with an elastic modulus 6.5MPa), to represent the jawbones with various cortical bone thicknesses and strengths of trabecular bone. A total of 60 bone specimens accompanied with implants was examined by a torque meter, Osstell resonance frequency analyzer, and Periotest electronic device. All data were statistically analyzed by two-way analysis of variance. In addition, second-order nonlinear regression was utilized to assess the correlations of the primary implant stability with the four cortex thicknesses and five strengths of trabecular bone. Results: ITV, ISQ, and PTV differed significantly (p<.05) and were strongly correlated with the thickness of cortical bone (R2>0.9) and the elastic modulus of trabecular bone (R2=0.740.99). Conclusions: The initial stability at the time of implant placement is influenced by both the cortical bone thickness and the strength of trabecular bone; however, these factors are mostly nonlinearly correlated with ITV, PTV, and ISQ. Using ITV and PTV seems more suitable for identifying the primary implant stability in osteoporotic bone with a thin cortex.
引用
收藏
页码:251 / 261
页数:11
相关论文
共 50 条
  • [21] Influence of the implant diameter and bone quality on the primary stability of porous tantalum trabecular metaldental implants: an invitro biomechanical study
    Romanos, Georgios E.
    Delgado-Ruiz, Rafael Arcesio
    Sacks, Danielle
    Luis Calvo-Guirado, Jose
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (06) : 649 - 655
  • [22] Evaluation of the Correlation Between the Structural Parameters of Trabecular Bone in CBCT and the Primary Stability of Dental Implants
    Shokri, Abbas
    Armand, Nafiseh
    Shahabi, Shiva
    Torkzaban, Parviz
    Tapak, Leili
    Poormoradi, Banafsheh
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (02) : 271 - 277
  • [23] In vitro evaluation of the influence of the cortical bone on the primary stability of two implant systems
    Andres-Garcia, Rodrigo
    Garcia Vives, Nuria
    Herrero Climent, Federico
    Fernandez Palacin, Ana
    Rios Santos, Vicente
    Herrero Climent, Mariano
    Bullon, Pedro
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2009, 14 (02): : E93 - E97
  • [24] The different contributions of cortical and trabecular bone to implant anchorage in a human vertebra
    Ruffoni, Davide
    Wirth, Andreas J.
    Steiner, Juri A.
    Parkinson, Ian H.
    Mueller, Ralph
    van Lenthe, G. Harry
    BONE, 2012, 50 (03) : 733 - 738
  • [25] The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis
    Sugiura, Tsutomu
    Yamamoto, Kazuhiko
    Horita, Satoshi
    Murakami, Kazuhiro
    Tsutsumi, Sadami
    Kirita, Tadaaki
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2016, 46 (03) : 152 - 165
  • [26] Evaluation of primary stability of implants in bovine bone defects models
    Kim, Minji
    Lee, Jae-Hyun
    Kim, Hyo-seon
    Lee, Su Young
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [27] Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study
    Tabassum, Afsheen
    Meijer, Gert J.
    Wolke, Johannes G. C.
    Jansen, John A.
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (02) : 213 - 220
  • [28] Alveolar Bone Density and Width Affect Primary Implant Stability
    de Elio Oliveros, Joaquin
    del Canto Diaz, Alejandra
    del Canto Diaz, Mariano
    Jacobo Orea, Clara
    del Canto Pingarron, Mariano
    Seco Calvo, Jesus
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (04) : 389 - 395
  • [29] Assessment of cortical bone thickness using ultrasound
    Degen, Katharina
    Habor, Daniel
    Radermacher, Klaus
    Heger, Stefan
    Kern, Jaana-Sophia
    Wolfart, Stefan
    Marotti, Juliana
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (05) : 520 - 528
  • [30] Effects on Ridge Dimensions, Bone Density, and Implant Primary Stability with Osseodensification Approach in Implant Osteotomy Preparation
    Yeh, Yu-Ting
    Chu, Tien-Min G.
    Blanchard, Steven B.
    Hamada, Yusuke
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (03) : 474 - 484