Analysis of optimal design configurations for a multiple disk centrifugal blood pump

被引:17
作者
Miller, GE
Fink, R
机构
[1] Virginia Commonwealth Univ, Biomed Engn Program, Richmond, VA 23298 USA
[2] Texas A&M Univ, Engn Technol Dept, College Stn, TX USA
关键词
rotary blood pump; centrifugal pump; multiple disk pump; ventricular assist; bridge to transplant;
D O I
10.1046/j.1525-1594.1999.06403.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A multiple disk centrifugal pump was analyzed as a blood pump for use in cardiac assistance or as a bridge to transplant device. The original configuration consisted of 6 parallel disks with 0.016 inch spacing between disks. This pump suffered from a degradation of now with increasing afterload. A study was conducted to analyze flow performance as a function of afterload, preload, and motor speed. Configurations were examined including 4, 5, and 6 disks each with spacings of 0.15, 0.20, and 0.25 inches. Flow rates were examined for variations in afterload from 60-130 mm Hg, in preload from 0-20 mm Hg and for motor speeds of 1,250, 1,500, and 1,750 rpm. Analyses of afterload effects were intended to determine those configurations that produced less flow degradation with increasing afterload. Analyses of motor speed effects were intended to determine any configurations that produced greater flow increases with increasing motor speed. A hemolysis study was also performed. Both plasma free hemoglobin and the index of hemolysis were compared to data reported for other centrifugal blood flow devices. Results indicated that a 5 disk configuration with a 0.15 inch spacing produced optimal flow results with minimal degradation at higher afterloads. No optimal configuration based upon motor speed was indicated. Preload effects on pump performance were minimal. Hemolysis results indicated minimal blood damage with levels below those of many other centrifugal blood pump designs.
引用
收藏
页码:559 / 565
页数:7
相关论文
共 19 条
  • [1] HARASAKI H, 1979, T AM SOC ART INT ORG, V25, P305
  • [2] HASINGER SH, 1963, ASME, V85, P201
  • [3] KLAIN M, 1971, T AM SOC ART INT ORG, V17, P437
  • [4] KOLFF WJ, 1975, T AM SOC ART INT ORG, V1, P620
  • [5] KWANGETT CS, 1969, T AM SOC ART INT ORG, V15, P245
  • [6] The heart-Hemopump interaction: A study of Hemopump flow as a function of cardiac activity
    Meyns, B
    Siess, T
    Laycock, S
    Reul, H
    Rau, G
    Flameng, W
    [J]. ARTIFICIAL ORGANS, 1996, 20 (06) : 641 - 649
  • [7] A MULTIPLE DISK CENTRIFUGAL PUMP AS A BLOOD-FLOW DEVICE
    MILLER, GE
    ETTER, BD
    DORSI, JM
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (02) : 157 - 163
  • [8] MILLER GE, 1993, ARTIF ORGANS, V17, P590
  • [9] A PRELIMINARY FLOW VISUALIZATION STUDY IN A MULTIPLE DISK CENTRIFUGAL ARTIFICIAL VENTRICLE
    MILLER, GE
    MADIGAN, M
    FINK, R
    [J]. ARTIFICIAL ORGANS, 1995, 19 (07) : 680 - 684
  • [10] MIZGUCHI K, 1995, ARTIF ORGANS, V19, P653