Metal artifact reduction MRI of total ankle arthroplasty implants

被引:29
作者
Netto, Cesar de Cesar [1 ,2 ]
Fonseca, Lucas F. [1 ]
Fritz, Benjamin [3 ,4 ]
Stern, Steven E. [5 ]
Raithel, Esther [6 ]
Nittka, Mathias [6 ]
Schon, Lew C. [1 ]
Fritz, Jan [2 ]
机构
[1] MedStar Union Mem Hosp, Dept Orthoped Surg, Baltimore, MD USA
[2] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21218 USA
[3] Balgrist Univ Hosp, Dept Radiol, Zurich, Switzerland
[4] Univ Zurich, Fac Med, Zurich, Switzerland
[5] Bond Univ, Bond Business Sch, Gold Coast, Qld, Australia
[6] Siemens Healthcare GmbH, Erlangen, Germany
关键词
Magnetic resonance imaging; Ankle; Arthroplasty; Artifacts; Joint prosthesis; TOTAL HIP-ARTHROPLASTY; SEMAC; REPLACEMENT; TIME; COMPLICATIONS; PROSTHESES; SEQUENCE;
D O I
10.1007/s00330-017-5153-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess high-bandwidth and compressed sensing-(CS)-SEMAC turbo spin echo (TSE) techniques for metal artifact reduction MRI of total ankle arthroplasty (TAA) implants. Following institutional approval and consent, 40 subjects with TAA implants underwent 1.5-T MRI prospectively. Evaluations included bone-implant interfaces, anatomical structures, abnormal findings and differential diagnoses before and after MRI. AUCs of P-P plots were used to determine superiority. Statistical differences were evaluated with McNemar and chi-square tests. P-values 0.05 were considered significant. CS-SEMAC TSE was superior to high-bandwidth TSE in showing the bone-implant interfaces (AUC=0.917), periprosthetic bone, tendons and joint capsule (AUC=0.337-0.766), bone marrow oedema (43 % difference, p=0.041), interface osteolysis (63 %, p=0.015), tendinopathy (62 %, p=0.062), periprosthetic fractures (60 %, p=0.250), synovitis (43 %, p=0.250), as well as reader confidence for bone marrow oedema (p=< 0.001), fracture (p=0.001), interface osteolysis (p=0.003), synovitis (p=0.027) and tendinopathy (p=0.034). The number of differential diagnoses in symptomatic subjects after the MRI with CS-SEMAC decreased from 3 (1-4) to 1 (1-2) (p < 0.001). MRI of TAA implants with CS-SEMAC improves the diagnosis of interface osteolysis, periprosthetic bone marrow oedema, fractures and tendinopathy when compared to high-BW TSE, and has a positive effect on patient management. aEuro cent High-bandwidth TSE and compressed sensing SEMAC improve MRI of ankle arthroplasty implants. aEuro cent Compressed sensing SEMAC improves bone-implant interfaces, periprosthetic bone, tendons and joint capsule visibility. aEuro cent Compressed sensing SEMAC improves the diagnosis of osteolysis, tendinopathy, fractures and synovitis. aEuro cent MRI decreases the number of clinical differential diagnoses of painful ankle arthroplasty implants.
引用
收藏
页码:2216 / 2227
页数:12
相关论文
共 38 条
[1]   MR imaging of soft tissue alterations after total hip arthroplasty: comparison of classic surgical approaches [J].
Agten, Christoph A. ;
Sutter, Reto ;
Dora, Claudio ;
Pfirrmann, Christian W. A. .
EUROPEAN RADIOLOGY, 2017, 27 (03) :1312-1321
[2]   Unicompartmental knee arthroplasty MRI: impact of slice-encoding for metal artefact correction MRI on image quality, findings and therapy decision [J].
Agten, Christoph A. ;
Del Grande, Filippo ;
Fucentese, Sandro F. ;
Blatter, Samuel ;
Pfirrmann, Christian W. A. ;
Sutter, Reto .
EUROPEAN RADIOLOGY, 2015, 25 (07) :2184-2193
[3]   SEMAC-VAT and MSVAT-SPACE Sequence Strategies for Metal Artifact Reduction in 1.5T Magnetic Resonance Imaging [J].
Ai, Tao ;
Padua, Abraham ;
Goerner, Frank ;
Nittka, Mathias ;
Gugala, Zbigniew ;
Jadhav, Siddharth ;
Trelles, Miguel ;
Johnson, Raleigh F. ;
Lindsey, Ronald W. ;
Li, Xiaoming ;
Runge, Val M. .
INVESTIGATIVE RADIOLOGY, 2012, 47 (05) :267-276
[4]   Postoperative evaluation of the total ankle arthroplasty [J].
Bestic, Joseph M. ;
Peterson, Jeffrey J. ;
DeOrio, James K. ;
Bancroft, Laura W. ;
Berquist, Thomas H. ;
Kransdorf, Mark J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) :1112-1123
[5]   Postoperative Imaging of the Total Ankle Arthroplasty [J].
Bestic, Joseph M. ;
Bancroft, Laura W. ;
Peterson, Jeffrey J. ;
Kransdorf, Mark J. .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2008, 46 (06) :1003-+
[6]   Imaging in Total Ankle Replacement [J].
Cadden, Anthony R. .
SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2012, 16 (03) :205-216
[7]   Intermediate to Long-Term Outcomes of Total Ankle Replacement with the Scandinavian Total Ankle Replacement (STAR) [J].
Daniels, Timothy R. ;
Mayich, D. Joshua ;
Penner, Murray J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2015, 97A (11) :895-903
[8]   Optimization of Scan Time in MRI for Total Hip Prostheses: SEMAC Tailoring for Prosthetic Implants Containing Different Types of Metals [J].
Deligianni, X. ;
Bieri, O. ;
Elke, R. ;
Wischer, T. ;
Egelhof, T. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (12) :1116-1122
[9]   Compressed Sensing SEMAC: 8-fold Accelerated High Resolution Metal Artifact Reduction MRI of Cobalt-Chromium Knee Arthroplasty Implants [J].
Fritz, Jan ;
Ahlawat, Shivani ;
Demehri, Shadpour ;
Thawait, Gaurav K. ;
Raithel, Esther ;
Gilson, Wesley D. ;
Nittka, Mathias .
INVESTIGATIVE RADIOLOGY, 2016, 51 (10) :666-676
[10]   Advanced metal artifact reduction MRI of metal-on-metal hip resurfacing arthroplasty implants: compressed sensing acceleration enables the time-neutral use of SEMAC [J].
Fritz, Jan ;
Fritz, Benjamin ;
Thawait, Gaurav K. ;
Raithel, Esther ;
Gilson, Wesley D. ;
Nittka, Mathias ;
Mont, Michael A. .
SKELETAL RADIOLOGY, 2016, 45 (10) :1345-1356