Precision of the optimized carbon monoxide rebreathing method to determine total haemoglobin mass and blood volume

被引:18
作者
Durussel, Jerome [1 ,2 ]
Ross, Ramzy [1 ]
Kodi, Prithvi Raj [1 ]
Daskalaki, Evangelia [1 ]
Takas, Pantazis [1 ]
Wilson, John [1 ]
Kayser, Bengt [2 ]
Pitsiladis, Yannis [1 ]
机构
[1] Univ Glasgow, Inst Cardiovasc & Med Sci, Coll Med Vet & Life Sci, Glasgow G12 8QQ, Lanark, Scotland
[2] Univ Geneva, Fac Med, Inst Movement Sci & Sports Med, Geneva, Switzerland
关键词
Carboxyhaemoglobin; comparison of methods; measurement error; HYBRID ALGORITHM HBMR; RED-CELL VOLUME; PLASMA-VOLUME; CO; STABILITY; SPORTS; TRANSFUSIONS; NONSMOKERS; CYCLISTS; MEDICINE;
D O I
10.1080/17461391.2011.606843
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The aim of this study was to evaluate the influence of different apparatuses, procedures and calculations on the precision of the optimized carbon monoxide method. Total haemoglobin mass was determined twice on consecutive days in 11 subjects using both venous and capillary blood samples. To estimate loss of carbon monoxide due to exhalation, carbon monoxide concentration was measured by two portable carbon monoxide analysers (Fluke CO-220, Fluke, Norwich, UK and Pac 7000 Carbon Monoxide, Draeger Safety, Northumberland, UK) and alveolar ventilation was specified using an automated metabolic gas analysis system (Cosmed Quark b2, Cosmed, Rome, Italy). Blood volume was derived from total haemoglobin mass using haemoglobin concentration and haematocrit obtained in both the supine and the seated position. Two different formulae to calculate blood volume were also compared. Precision was good for both total haemoglobin mass and blood volume measurements performed on consecutive days (typical error < 2%). Using Fluke CO-220 analyser, an estimated alveolar ventilation and capillary blood, total haemoglobin mass (917 +/- 136 g) was similar when compared to the Pac 7000 Draeger CO-analyser (904 +/- 137 g; mean bias 13 g with 95% limits of agreement 26 to + 1 g, P=0.76), specified alveolar ventilation (911 +/- 132 g, mean bias 6 g with 95% limits of agreement 18 g to + 6 g, P =0.87) and venous blood (917 +/- 134 g, mean bias 0 g with 95% limits of agreement 38 to + 38 g, P=0.99), respectively. Blood volume determination was also not significantly affected by the supine vs. seated position (6.7 +/- 0.8 l vs. 6.6 +/- 0.8 l, P=0.56) but can deviate by 0.6 l (P=0.01) depending on the formula applied. Thus, the good precision of the assessment of total haemoglobin mass and blood volume using the optimized carbon monoxide rebreathing method is not significantly influenced by the make of CO analyser, method of obtaining alveolar ventilation, blood sampling method and subject position, but should for longitudinal monitoring purposes use the same formula.
引用
收藏
页码:68 / 77
页数:10
相关论文
共 57 条
[1]  
Ahlgrim C., 2010, INT J LAB HEMATOL, V32, P1
[2]   A world apart Inaccuracies of laboratory methodologies in antidoping testing [J].
Banfi, Giuseppe ;
Lombardi, Giovanni ;
Colombini, Alessandra ;
Lippi, Giuseppe .
CLINICA CHIMICA ACTA, 2010, 411 (15-16) :1003-1008
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   DETERMINATION OF HEMOGLOBIN MASS AND BLOOD-VOLUME WITH CO - EVALUATION AND APPLICATION OF A METHOD [J].
BURGE, CM ;
SKINNER, SL .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 79 (02) :623-631
[5]   Effects of acute hypoventilation and hyperventilation on exhaled carbon monoxide measurement in healthy volunteers [J].
Cavaliere F. ;
Volpe C. ;
Gargaruti R. ;
Poscia A. ;
Di Donato M. ;
Grieco G. ;
Moscato U. .
BMC Pulmonary Medicine, 9 (1)
[6]   THE BODY VENOUS HEMATOCRIT RATIO - ITS CONSTANCY OVER A WIDE HEMATOCRIT RANGE [J].
CHAPLIN, H ;
MOLLISON, PL ;
VETTER, H .
JOURNAL OF CLINICAL INVESTIGATION, 1953, 32 (12) :1309-1316
[7]  
Chatkin Jose, 2007, Prim Care Respir J, V16, P36, DOI 10.3132/pcrj.2007.00008
[8]   ACCURACY OF A NEW BEDSIDE METHOD FOR ESTIMATION OF CIRCULATING BLOOD-VOLUME [J].
CHRISTENSEN, P ;
RASMUSSEN, JW ;
HENNEBERG, SW .
CRITICAL CARE MEDICINE, 1993, 21 (10) :1535-1540
[9]   Time course of haemoglobin mass during 21 days live high:train low simulated altitude [J].
Clark, Sally A. ;
Quod, M. J. ;
Clark, M. A. ;
Martin, D. T. ;
Saunders, P. U. ;
Gore, C. J. .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2009, 106 (03) :399-406
[10]   CONSIDERATIONS OF PHYSIOLOGICAL VARIABLES THAT DETERMINE BLOOD CARBOXYHEMOGLOBIN CONCENTRATION IN MAN [J].
COBURN, RF ;
FORSTER, RE ;
KANE, PB .
JOURNAL OF CLINICAL INVESTIGATION, 1965, 44 (11) :1899-&