摘要
Thermoacoustic refrigerators have huge potential to replace conventional refrigeration systems as an alternative clean refrigeration technology. These devices utilize conversion of acoustic power and heat energy to generate the desired cooling. The stack plays a pivotal role in the performance of Standing Wave Thermoacoustic Refrigerators (SWTARs), as the heat transfer takes place across it. Performance of stacks can be significantly improved by making an arrangement of different materials inside the stack, resulting in anisotropic thermal properties along the length. In the present numerical study, the effect of multi-layered stack on the refrigeration performance of a SWTAR has been evaluated in terms of temperature drop across the stack, acoustic power consumed and device Coefficient of Performance (COP). Two different aspects of multi-layered stack, namely, different material combinations and different lengths of stacked layers, have been investigated. The combinations of four stack materials and length ratios have been investigated. The numerical results showed that multi-layered stacks produce lower refrigeration temperatures, consume less energy and have higher COP value than their homogeneous counterparts. Among all the material combinations of multi-layered stack investigated, stacks composed of a material layer with low thermal conductivity at the ends, i.e., RVC, produced the best performance with an increase of 26.14% in temperature drop value, reduction in the acoustic power consumption by 4.55% and COP enhancement of 5.12%. The results also showed that, for a constant overall length, an increase in length of side stacked material layer results in an increase in values of both temperature drop and COP.
引用
收藏
页数:25
相关论文
共 38 条
  • [1] Computational Fluid Dynamics Simulation of a Thermoacoustic Refrigerator
    Abd El-Rahman, Ahmed I.
    Abdel-Rahman, Ehab
    [J]. JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2014, 28 (01) : 78 - 86
  • [2] Porous Cores in Small Thermoacoustic Devices for Building Applications
    Auriemma, Fabio
    Di Giulio, Elio
    Napolitano, Marialuisa
    Dragonetti, Raffaele
    [J]. ENERGIES, 2020, 13 (11)
  • [3] Design and optimization of thermoacoustic devices
    Babaei, Hadi
    Siddiqui, Kamran
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (12) : 3585 - 3598
  • [4] Influence of heat exchangers blockage ratio on the performance of thermoacoustic refrigerator
    Belaid, Kheira Nehar
    Hireche, Omar
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 127 : 834 - 842
  • [5] Energy flux density in a thermoacoustic couple
    Cao, N
    Olson, JR
    Swift, GW
    Chen, S
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1996, 99 (06) : 3456 - 3464
  • [6] De Jong J.A., 2015, P EUR C NOIS CONTR E, V2015, P527
  • [7] A 3D investigation of thermoacoustic fields in a square stack
    El-Rahman, Ahmed I. Abd
    Abdelfattah, Waleed A.
    Fouad, Mahmoud A.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 108 : 292 - 300
  • [8] Gardner D.L., 2009, P ACOUSTICS AD AUSTR
  • [9] Development and Assessment of Two-Stage Thermoacoustic Electricity Generator
    Hamood, Ahmed
    Jaworski, Artur J.
    Mao, Xiaoan
    [J]. ENERGIES, 2019, 12 (09)
  • [10] System Identification and Resonant Control of Thermoacoustic Engines for Robust Solar Power
    Hong, Boe-Shong
    Lin, Tsu-Yu
    [J]. ENERGIES, 2015, 8 (05) : 4138 - 4159