Continuous measurement of segmental and whole body bio-impedance

被引:0
|
作者
Zhu, FS [1 ]
Schneditz, D [1 ]
Wang, EJ [1 ]
Levin, NW [1 ]
机构
[1] Beth Israel Deaconess Med Ctr, New York, NY 10128 USA
来源
PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING | 1997年 / 19卷
关键词
bioimpedance; extracellular resistance; segmental measurement; regional fluid distribution; MULTIFREQUENCY IMPEDANCE; WATER; BIOIMPEDANCE; DIALYSIS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Measurement of whole body bioimpedance provides a non-invasive and practical approach to estimate extracellular volume (ECV) in man. However, recent data indicate that ECV cannot be treated as a homogeneous compartment without obtaining paradoxical results. Therefore, bioimpedance measurements should include measurements of body segments such as the arm, the trunk, and the leg. A digital switch was developed and used to consecutively select different body segments for the continuous measurement of whole body and segmental bioimpedance at a minimum sampling period of 3 seconds. Bioimpedance data were modeled to determine the resistance of the ECV in the segments and in the whole body for a period of 30 minutes where subjects were in supine body position followed by a 30 minute standing phase. During supine body position modeled extracellular resistance increased in the leg, the arm, and in the whole body but slightly increased in the trunk. Changes in extracellular resistance reversed with subjects assuming a standing position. These measurements reflect the shifts in ECV between segments to be expected with changes in body position. Simultaneous measurement of bioimpedance in different body segments utilizing this approach might be useful to analyze the nature of fluid shifts in clinical applications such as hemodialysis and ultrafiltration.
引用
收藏
页码:2086 / 2088
页数:3
相关论文
共 50 条
  • [31] Prediction of body-fat percentage from skinfold and bio-impedance measurements in Indian school children
    Kehoe, S. H.
    Krishnaveni, G. V.
    Lubree, H. G.
    Wills, A. K.
    Guntupalli, A. M.
    Veena, S. R.
    Bhat, D. S.
    Kishore, R.
    Fall, C. H. D.
    Yajnik, C. S.
    Kurpad, A.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2011, 65 (12) : 1263 - 1270
  • [32] Development of a Segmental Bioelectrical Impedance Spectroscopy Device for Body Composition Measurement
    Cannon, Thomas
    Choi, JungHun
    SENSORS, 2019, 19 (22)
  • [33] Prediction of body-fat percentage from skinfold and bio-impedance measurements in Indian school children
    S H Kehoe
    G V Krishnaveni
    H G Lubree
    A K Wills
    A M Guntupalli
    S R Veena
    D S Bhat
    R Kishore
    C H D Fall
    C S Yajnik
    A Kurpad
    European Journal of Clinical Nutrition, 2011, 65 : 1263 - 1270
  • [34] Evaluation of a bio-impedance method for measuring human arm movement
    Kim, JC
    Kim, SC
    Nam, KC
    Ahn, SH
    Park, M
    Kim, DW
    YONSEI MEDICAL JOURNAL, 2002, 43 (05) : 637 - 643
  • [35] Detection of Stenosis in Blood Vessel by Using Bio-impedance Analysis
    Shash, Yomna H.
    Eldosoky, Mohamed A. A.
    Elwakad, Mohamed T.
    2018 35TH NATIONAL RADIO SCIENCE CONFERENCE (NRSC), 2018, : 503 - 512
  • [36] Bio-impedance and circuit parameters: An analysis for tracking fruit ripening
    Ibba, Pietro
    Falco, Aniello
    Abera, Biresaw Demelash
    Cantarella, Giuseppe
    Petti, Luisa
    Lugli, Paolo
    POSTHARVEST BIOLOGY AND TECHNOLOGY, 2020, 159
  • [37] A Tetrapolar Bio-Impedance Sensing System for Gastrointestinal Tract Monitoring
    Kassanos, Panagiotis
    Ip, Henry M. D.
    Yang, Guang-Zhong
    2015 IEEE 12TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2015,
  • [38] CLASSIFICATION OF HUMAN TISSUE BY THE ELECTRICAL BIO-IMPEDANCE WITH MULTILAYER PERCEPTRON
    Novakovic, Jasmina
    Veljovic, Alempije
    METALURGIA INTERNATIONAL, 2011, 16 (12): : 140 - 146
  • [39] A New Method for Detection of Leg Movement using Bio-impedance
    Kim, K. S.
    Lee, S. O.
    Kim, S. C.
    Kim, D. W.
    Seo, J. H.
    Kim, K. S.
    Song, C. G.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3956 - +
  • [40] Analysis of breast bio-impedance using a finite element method
    Zhao, X
    Ihara, A
    Kinouchi, Y
    Morimoto, T
    Takeuchi, M
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 753 - 754