摘要
Using a multilevel approach, we estimated the effects of classroom ventilation rate and temperature on academic achievement. The analysis is based on measurement data from a 70 elementary school district (140 fifth grade classrooms) from Southwestern United States, and student level data (N = 3109) on socioeconomic variables and standardized test scores. There was a statistically significant association between ventilation rates and mathematics scores, and it was stronger when the six classrooms with high ventilation rates that were indicated as outliers were filtered (>7.1 l/s per person). The association remained significant when prior year test scores were included in the model, resulting in less unexplained variability. Students' mean mathematics scores (average 2286 points) were increased by up to eleven points (0.5%) per each liter per second per person increase in ventilation rate within the range of 0.9-7.1 l/s per person (estimated effect size 74 points). There was an additional increase of 12-13 points per each 1 degrees C decrease in temperature within the observed range of 20-25 degrees C (estimated effect size 67 points). Effects of similar magnitude but higher variability were observed for reading and science scores. In conclusion, maintaining adequate ventilation and thermal comfort in classrooms could significantly improve academic achievement of students.
引用
收藏
页数:14
相关论文
共 25 条
[1]  
[Anonymous], 2004, 6212004 ANSIASHRAE
[2]  
[Anonymous], 1997, EXP FACT HDB
[3]  
[Anonymous], 2007, D6245 ASTM
[4]  
ASHRAE, 1992, ASHRAE standard 55-1992
[5]   Ventilation rates in schools and pupils' performance [J].
Bako-Biro, Zs. ;
Clements-Croome, D. J. ;
Kochhar, N. ;
Awbi, H. B. ;
Williams, M. J. .
BUILDING AND ENVIRONMENT, 2012, 48 :215-223
[6]  
Balfanz R., 2012, Chronic absenteeism: Summarizing what we know from nationally available data
[7]  
Bearg D.W., 1993, INDOOR AIR QUALITY H, DOI DOI 10.1201/9780203751152
[8]  
Dunn R., 1990, J MULTICULTURAL COUN, V18, P68
[9]  
Ewing N.J., 1992, Roeper Review, V14
[10]   Association between substandard classroom ventilation rates and students' academic achievement [J].
Haverinen-Shaughnessy, U. ;
Moschandreas, D. J. ;
Shaughnessy, R. J. .
INDOOR AIR, 2011, 21 (02) :121-131