Test-retest repeatability of strength capacity, aerobic power and pericranial tenderness of neck and shoulder muscles in children - relevant for tension-type headache

被引:7
作者
Tornoe, Birte [1 ,2 ,5 ,6 ]
Andersen, Lars L. [3 ]
Skotte, Jorgen H. [3 ]
Jensen, Rigmor [4 ]
Gard, Gunvor [1 ]
Skov, Liselotte [2 ]
Hallstrom, Inger [1 ]
机构
[1] Lund Univ, Dept Hlth Sci, Scania, Sweden
[2] Univ Copenhagen, Herlev Hosp, Childrens Headache Clin, Dept Pediat, DK-2730 Herlev, Denmark
[3] Natl Res Ctr Working Environm, Copenhagen, Denmark
[4] Univ Copenhagen, Danish Headache Ctr, Dept Neurol, Glostrup Hosp, Glostrup, Denmark
[5] Univ Copenhagen, Glostrup Hosp, Dept Physiotherapy & Occupat Therapy, Glostrup, Denmark
[6] Univ Copenhagen, Herlev Hosp, Dept Physiotherapy, Dept Med, DK-2730 Herlev, Denmark
关键词
muscle strength; intratester reliability; cardiovascular fitness;
D O I
10.2147/JPR.S46344
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Frequent or chronic tension-type headache in children is a prevalent and debilitating condition for the child, often leading to medication overuse. To explore the relationship between physical factors and tension-type headache in children, the quality of repeated measures was examined. The aim of the present study was to determine the test-retest repeatability of parameters determining isometric neck and shoulder strength and stability, aerobic power, and pericranial tenderness in children. Methods: Twenty-five healthy children, 9 to 18 years of age, participated in test-retest procedures within a 1-week interval. A computerized padded force transducer was used for testing. The tests included the isometric maximal voluntary contraction and force steadiness of neck flexion and extension, and the isometric maximal voluntary contraction and rate of force of the dominant shoulder. Pericranial tenderness was recorded by means of standardized manual palpation, and a submaximal cycle ergometer test predicted maximal oxygen uptake (VO2 max). The measurements were evaluated in steps, using the intraclass correlation coefficient (ICC); changes in the mean between the two test occasions; the levels of agreement, visualized in Bland-Altman Plots; and by quantifying the variability. Results: The results showed an acceptable test-retest repeatability of isometric maximal voluntary contraction (ICC 0.90-0.97). The force steadiness measurements revealed a trend of systematic changes in the direction of neck flexion and need further examination in both healthy and ill children. The rate of force development, Total Tenderness Score, and prediction of VO2 max showed repeatability, with ICC 0.80-0.87. Conclusion: The measurements of strength capacity, aerobic power, and tenderness provide acceptable repeatability, suitable for research in children.
引用
收藏
页码:643 / 651
页数:9
相关论文
共 32 条
[1]   Effectiveness of small daily amounts of progressive resistance training for frequent neck/shoulder pain: Randomised controlled trial [J].
Andersen, Lars L. ;
Saervoll, Charlotte A. ;
Mortensen, Ole S. ;
Poulsen, Otto M. ;
Hannerz, Harald ;
Zebis, Mette K. .
PAIN, 2011, 152 (02) :440-446
[2]   Rapid muscle activation and force capacity in conditions of chronic musculoskeletal pain [J].
Andersen, Lars L. ;
Holtermann, Andreas ;
Jorgensen, Marie B. ;
Sjogaard, Gisela .
CLINICAL BIOMECHANICS, 2008, 23 (10) :1237-1242
[3]  
[Anonymous], 1989, UN CONV RIGHTS CHILD
[4]   Determinants of tension-type headache in children [J].
Anttila, P ;
Metsähonkala, L ;
Aromaa, M ;
Sourander, A ;
Salminen, J ;
Helenius, H ;
Alanen, P ;
Sillanpää, M .
CEPHALALGIA, 2002, 22 (05) :401-408
[5]   Pain sensitivity in pericranial and extracranial regions [J].
Ashina, S ;
Jensen, R ;
Bendtsen, L .
CEPHALALGIA, 2003, 23 (06) :456-462
[6]  
Astrand P., 2003, Textbook of Work Physiology. Physiological Basis of Exercise, V4th
[7]   PRESSURE-CONTROLLED PALPATION - A NEW TECHNIQUE WHICH INCREASES THE RELIABILITY OF MANUAL PALPATION [J].
BENDTSEN, L ;
JENSEN, R ;
JENSEN, NK ;
OLESEN, J .
CEPHALALGIA, 1995, 15 (03) :205-210
[8]   MUSCLE PALPATION WITH CONTROLLED FINGER PRESSURE - NEW EQUIPMENT FOR THE STUDY OF TENDER MYOFASCIAL TISSUES [J].
BENDTSEN, L ;
JENSEN, R ;
JENSEN, NK ;
OLESEN, J .
PAIN, 1994, 59 (02) :235-239
[9]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[10]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310