Automated Method for Simultaneous Lead and Strontium Isotopic Analysis Applied to Rainwater Samples and Airborne Particulate Filters (PM10)

被引:11
作者
Beltran, Blanca [1 ]
Avivar, Jessica [2 ]
Mola, Montserrat [4 ]
Ferrer, Laura [2 ]
Cerda, Victor [3 ]
Leal, Luz O. [1 ]
机构
[1] Adv Mat Res Ctr CIMAV SC, Renewable Energy & Environm Protect Dept, Chihuahua 31109, Chih, Mexico
[2] Univ Balearic Isl, Environm Radioact Lab, Palma De Mallorca 07122, Spain
[3] Univ Balearic Isl, Dept Chem, Palma De Mallorca 07122, Spain
[4] Univ Rovira & Virgili, Dept Analyt Chem & Organ Chem, E-43007 Tarragona, Spain
关键词
ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; LAB-ON-VALVE; ONLINE PRECONCENTRATION; EXPERIMENTAL-DESIGN; TRACE AMOUNTS; ICP-MS; SR; PB; RATIOS;
D O I
10.1021/es400118w
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new automated, sensitive, and fast system for the simultaneous online isolation and preconcentration of lead and strontium by sorption on a microcolumn packed with Sr-resin using an inductively coupled plasma mass spectrometry (ICP-MS) detector was developed, hyphenating lab-on-valve (LOV) and multisyringe flow injection analysis (MSFIA). Pb and Sr are directly retained on the sorbent column and eluted with a solution of 0.05 L-1 ammonium oxalate. The detection limits achieved were 0.04 ng for lead and 0.03 ng for strontium. Mass calibration curves were used since the proposed system allows the use of different sample volumes for preconcentration. Mass linear working ranges were between 0.13 and 50 ng and 0.1 and 50 ng for lead and strontium, respectively. The repeatability of the method, expressed as RSD, was 2.1% and 2.7% for Pb and Sr, respectively. Environmental samples such as rainwater and airborne particulate (PM10) filters as well as a certified reference material SLRS-4 (river water) were satisfactorily analyzed obtaining recoveries between 90 and 110% for both elements. The main features of the LOV-MSFIA-ICP-MS system proposed are the capability to renew solid phase extraction at will in a fully automated way, the remarkable stability of the column which can be reused up to 160 times, and the potential to perform isotopic analysis.
引用
收藏
页码:9850 / 9857
页数:8
相关论文
共 39 条
[1]   Man, nutrition and mobility:: A comparison of teeth and bone from the Medieval era and the present from Pb and Sr isotopes [J].
Åberg, G ;
Fosse, G ;
Stray, H .
SCIENCE OF THE TOTAL ENVIRONMENT, 1998, 224 (1-3) :109-119
[2]   Experimental design .1. Screening [J].
Araujo, PW ;
Brereton, RG .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (01) :26-31
[3]   Fully automated lab-on-valve-multisyringe flow injection analysis-ICP-MS system: an effective tool for fast, sensitive and selective determination of thorium and uranium at environmental levels exploiting solid phase extraction [J].
Avivar, Jessica ;
Ferrer, Laura ;
Casas, Montserrat ;
Cerda, Victor .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (02) :327-334
[4]   Determination of total lead and lead isotope ratios in natural waters by inductively coupled plasma time-of-flight mass spectrometry after flow injection on-line preconcentration [J].
Benkhedda, K ;
Infante, HG ;
Adams, FC .
ANALYTICA CHIMICA ACTA, 2004, 506 (02) :137-144
[5]   Lab-on-valve:: a useful tool in biochemical analysis [J].
de Castro, M. D. Luque ;
Ruiz-Jimenez, J. ;
Perez-Serradilla, J. A. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (02) :118-126
[6]  
Dehelean A, 2012, ROM J PHYS, V57, P1194
[7]   Single-stage method for the simultaneous isolation of lead and strontium from silicate samples for isotopic measurements [J].
Deniel, C ;
Pin, C .
ANALYTICA CHIMICA ACTA, 2001, 426 (01) :95-103
[8]  
Elburg MA, 2010, GEOL BELG, V13, P121
[9]   Determination of lead in wine and rum samples by flow injection-hydride generation-atomic absorption spectrometry [J].
Elci, Latif ;
Arslan, Zikri ;
Tyson, Julian F. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 162 (2-3) :880-885
[10]   Isotope ratio measurements using gas chromatography inductively coupled plasma mass spectrometry for the assessment of organolead sources [J].
Encinar, JR ;
Granadillo, IL ;
Alonso, JIG ;
Sanz-Medel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (05) :475-480