摘要
The development of mobile systems for monitoring bioelectric signals outside a hospital environment involves many challenges that do not arise when it is in a controlled environment, like a hospital. The dimensions of these systems are an important factor to consider in order to facilitate their use without interfering with the daily activities of individuals. The purpose of this work is the implementation of a single-supply battery-powered, low power ECG/EMG signal monitoring system based on the ADS1198 Analog Front-End from Texas Instruments. The system was designed to acquire ECG signals from three electrodes using the integrated Right-Leg-Drive (RLD) circuit from the ADS1198. The developed analog front-end was connected for testing purposes through the SPI interface to a NI-USB 8451 board and signals were acquired using LabVIEW. The circuit was tested in several situations and proved to provide high quality signals using textile integrated electrodes and conventional disposable gel electrodes.
引用
收藏
页码:325 / 330
页数:6
相关论文
共 14 条
[1]  
Aguirre R E.J.F.R., 2012, 15 S TRAT SEN IM VIS
[2]  
[Anonymous], 1998, Medical Instrumentation: Application and Design
[3]  
Catarino A., 2011, P AUTEX 2011 C 8 10, P807
[4]  
CATARINO A, 2012, FIB SOC 2012 FALL M
[5]  
Catarino A, 2012, 2012 INT C EXP EL PO
[6]  
Catarino A.P., P TRS2012 41 TEXT RE
[7]   60-HZ INTERFERENCE IN ELECTROCARDIOGRAPHY [J].
HUHTA, JC ;
WEBSTER, JG .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1973, BM20 (02) :91-101
[8]  
Mankodiya K., 2010, P 5 INT WORKSH UB HL
[9]   AC-coupled front-end for biopotential measurements [J].
Spinelli, EM ;
Pallàs-Areny, R ;
Mayosky, MA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (03) :391-395
[10]   HIGH-QUALITY RECORDING OF BIOELECTRIC EVENTS .1. INTERFERENCE REDUCTION, THEORY AND PRACTICE [J].
VANRIJN, ACM ;
PEPER, A ;
GRIMBERGEN, CA .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (05) :389-397