A direct comparison of the sensitivity of CT and MR cardiac perfusion using a myocardial perfusion phantom

被引:15
作者
Otton, James [1 ,2 ]
Morton, Geraint [1 ]
Schuster, Andreas [3 ,4 ]
Bigalke, Boris [1 ,5 ]
Marano, Riccardo [1 ]
Olivotti, Luca [1 ]
Nagel, Eike [1 ]
Chiribiri, Amedeo [1 ]
机构
[1] Kings Coll London, Div Imaging Sci, Rayne Inst, St Thomas Hosp, London SE1 7EH, England
[2] Univ New S Wales, Sydney, NSW, Australia
[3] Univ Gottingen, Dept Cardiol & Pulmonol, D-37073 Gottingen, Germany
[4] German Ctr Cardiovasc Res, Gottingen, Germany
[5] Univ Tubingen, Med Klin 3, Tubingen, Germany
基金
英国惠康基金; 英国医学研究理事会; 英国工程与自然科学研究理事会;
关键词
Cardiac magnetic resonance perfusion; Cardiac CT perfusion; Phantom; Cardiac computed tomography; Myocardial perfusion imaging; Myocardial CT perfusion; Cardiac MRI; CARDIOVASCULAR MAGNETIC-RESONANCE; CORONARY-ARTERY-DISEASE; EMISSION-COMPUTED-TOMOGRAPHY; BLOOD-FLOW QUANTIFICATION; ADENOSINE-STRESS; ANIMAL-MODEL; DECONVOLUTION; ANGIOGRAPHY; RESERVE; DESIGN;
D O I
10.1016/j.jcct.2013.01.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Direct comparison of CT and magnetic resonance (MR) perfusion techniques has been limited and in vivo assessment is affected by physiological variability, timing of image acquisition, and parameter selection. Objective: We precisely compared high-resolution k-t SENSE MR cardiac perfusion at 3 T with single-phase CT perfusion (CTP) under identical imaging conditions. Methods: We used a customized MR imaging and CT compatible dynamic myocardial perfusion phantom to represent the human circulation. CT perfusion studies were performed with a Philips iCT (256 slice) CT, with isotropic resolution of 0.6 mm(3). MR perfusion was performed with k-t SENSE acceleration at 3 T and spatial resolution of 1.2 x 1.2 x 10 mm. The image contrast between normal and underperfused myocardial compartments was quantified at various perfusion and photon energy settings. Noise estimates were based on published clinical data. Results: Contrast by CTP highly depends on photon energy and also timing of imaging within the myocardial perfusion upslope. For an identical myocardial perfusion deficit, the native image contrast-to-noise ratio (CNR) generated by CT and MR are similar. If slice averaging is used, the CNR of a perfusion deficit is expected to be greater for CTP than MR perfusion (MRP). Perfect timing during single time point CTP imaging is difficult to achieve, and CNR by CT decreases by 24%-31% two seconds from the optimal imaging time point. Although single-phase CT perfusion offers higher spatial resolution, MRP allows multiple time point sampling and quantitative analysis. Conclusion: The ability of CTP and current optimal MRP techniques to detect simulated myocardial perfusion deficits is similar. Crown Copyright (c) 2013 Published by Elsevier Inc. on behalf of Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:117 / 124
页数:8
相关论文
共 32 条
[1]   Dynamic myocardial stress perfusion imaging using fast dual-source CT with alternating table positions: initial experience [J].
Bamberg, Fabian ;
Klotz, Ernst ;
Flohr, Thomas ;
Becker, Alexander ;
Becker, Christoph R. ;
Schmidt, Bernhard ;
Wintersperger, Bernd J. ;
Reiser, Maximilian F. ;
Nikolaou, Konstantin .
EUROPEAN RADIOLOGY, 2010, 20 (05) :1168-1173
[2]   Adenosine-Stress Dynamic Myocardial CT Perfusion Imaging Initial Clinical Experience [J].
Bastarrika, Gorka ;
Ramos-Duran, Luis ;
Rosenblum, Michael A. ;
Kang, Doo Kyoung ;
Rowe, Garrett W. ;
Schoepf, U. Joseph .
INVESTIGATIVE RADIOLOGY, 2010, 45 (06) :306-313
[3]   Cardiovascular magnetic resonance perfusion imaging at 3-Tesla for the detection of coronary artery disease - A comparison with 1.5-Tesla [J].
Cheng, Adrian S. H. ;
Pegg, Tammy J. ;
Karamitsos, Theodoros D. ;
Searle, Nick ;
Jerosch-Herold, Michael ;
Choudhury, Robin P. ;
Adrian, P. Banning ;
Neubauer, Stefan ;
Robson, Matthew D. ;
Selvanayagam, Joseph B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (25) :2440-2449
[4]   Perfusion phantom: An efficient and reproducible method to simulate myocardial first-pass perfusion measurements with cardiovascular magnetic resonance [J].
Chiribiri, Amedeo ;
Schuster, Andreas ;
Ishida, Masaki ;
Hautvast, Gilion ;
Zarinabad, Niloufar ;
Morton, Geraint ;
Otton, James ;
Plein, Sven ;
Breeuwer, Marcel ;
Batchelor, Philip ;
Schaeffter, Tobias ;
Nagel, Eike .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (03) :698-707
[5]   Myocardial perfusion imaging with first-pass computed tomographic imaging: Measurement of coronary flow reserve in an animal model of regional hyperemia [J].
Christian, Timothy F. ;
Frankish, Mei Lee ;
Sisemoore, Jennifer H. ;
Christian, Madeline R. ;
Gentchos, George ;
Bell, Stephen P. ;
Jerosch-Herold, Michael .
JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (04) :625-630
[6]   Adenosine Stress High-Pitch 128-Slice Dual-Source Myocardial Computed Tomography Perfusion for Imaging of Reversible Myocardial Ischemia Comparison With Magnetic Resonance Imaging [J].
Feuchtner, Gudrun ;
Goetti, Robert ;
Plass, Andre ;
Wieser, Monika ;
Scheffel, Hans ;
Wyss, Christophe ;
Stolzmann, Paul ;
Donati, Olivio ;
Schnabl, Johannes ;
Falk, Volkmar ;
Alkadhi, Hatem ;
Leschka, Sebastian ;
Cury, Ricardo C. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2011, 4 (05) :540-549
[7]   Multidetector computed tomography myocardial perfusion imaging during adenosine stress [J].
George, Richard T. ;
Silva, Caterina ;
Cordeiro, Marco A. S. ;
DiPaula, Anthony ;
Thompson, Douglas R. ;
McCarthy, William F. ;
Ichihara, Takashi ;
Lima, Joao A. C. ;
Lardo, Albert C. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (01) :153-160
[8]   Impact of iterative reconstruction on CNR and SNR in dynamic myocardial perfusion imaging in an animal model [J].
Gramer, B. M. ;
Muenzel, D. ;
Leber, V. ;
von Thaden, A. -K. ;
Feussner, H. ;
Schneider, A. ;
Vembar, M. ;
Soni, N. ;
Rummeny, E. J. ;
Huber, A. M. .
EUROPEAN RADIOLOGY, 2012, 22 (12) :2654-2661
[9]   Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trial [J].
Greenwood, John P. ;
Maredia, Neil ;
Younger, John F. ;
Brown, Julia M. ;
Nixon, Jane ;
Everett, Colin C. ;
Bijsterveld, Petra ;
Ridgway, John P. ;
Radjenovic, Aleksandra ;
Dickinson, Catherine J. ;
Ball, Stephen G. ;
Plein, Sven .
LANCET, 2012, 379 (9814) :453-460
[10]   Non-contrast cardiac computed tomography can accurately detect chronic myocardial infarction: Validation study [J].
Gupta, Mohit ;
Kadakia, Jigar ;
Hacioglu, Yalcin ;
Ahmadi, Naser ;
Patel, Amish ;
Choi, Taeyoung ;
Yamada, Gregg ;
Budoff, Matthew .
JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (01) :96-103