Comparison of double phase Tc-99m MIBI and Tc-99m Tetrofosmin scintimammography for characterization of breast lesions: Visual and quantitative analyses

被引:0
|
作者
Kim, I. J. [1 ,2 ]
Kim, S. J. [1 ,2 ]
Kim, Y. K. [1 ,2 ]
机构
[1] Pusan Natl Univ, Sch Med, Dept Nucl Med, Pusan 602739, South Korea
[2] Pusan Natl Univ, Sch Med, Med Res Inst, Pusan 602739, South Korea
关键词
breast cancer; Tc-99m MIBI; Tc-99m Tetrofosmin;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of the current study was to compare the diagnostic reliability Of Visual and quantitative indices of double phase Tc-99m MIBI scintimammography (M-SMM) and Tc-99m Tetrofosmin scintimammography (TF-SMM) for detection of breast cancer. Double phase M-SMM and TF-SMM (early: 10 minutes, delayed; hour) were performed after injection of 925 MBq of radiotracers in 75 highly Suspected breast cancer patients (malignant:49, benign:26). For visual analysis, five scoring methods were used. For quantitative analysis, early, delayed lesions to non-lesion ratios (L/Ns), and washout rate (%, WR) were calculated. When over grade of visual grade was used as cut-off value in the detection of primary breast cancer, M-SMM and TF-SMM showed similar diagnostic accuracies. The optimal quantitative indices of M-SMM for the detection of breast cancer were 2.06 for early L/N and 1.72 for delayed L/N. Those of TF-SMM were 3.13 for early, and 2.56 for delayed image. Visual and quantitative analyses showed similar results. However, delayed UN of M-SMM was superior to that of TF-SMM for the detection of breast cancer. In conclusion, the double phase M-SMM and TF-SMM showed favorable diagnostic accuracy in differentiating benign from malignant breast lesions, visually and quantitatively. The optimal visual interpretation grades for the detection of primary breast cancer of double phase M-SMM and TF-SMM were oracle and 5. The optimal quantitative indices of M-SMM for the detection of breast cancer were 2.06 for early L/N and 1.72 for delayed UN. Those of TF-SMM were 3.13 for early, and 2.56 for delayed image.
引用
收藏
页码:526 / 531
页数:6
相关论文
共 50 条
  • [1] Characterization of breast lesion using double phase Tc-99m Tetrofosmin scintimammography: Comparison of visual and quantitative analyses
    Lee, JS
    Kim, SJ
    Kim, IJ
    Bae, YT
    Kim, YK
    Kang, YS
    Kim, DS
    EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (01) : 76 - 80
  • [2] Scintimammography for the detection of breast cancer: Comparison between Tc-99m MIBI and Tc-99m tetrofosmin.
    Home, T
    Pappo, I
    Cohenpur, M
    Baumer, M
    Orda, R
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (01): : S92 - S92
  • [3] The comparision of Tc-99m MIBI and Tc-99m MDP scintimammography in detection of breast lesions
    Atalay, M
    Uluc, E
    Polat, M
    Gür, S
    Çökmez, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1119 - 1119
  • [4] Comparison of Tc-99m THY and Tc-99m MIBI scans for diagnosis of breast lesions
    Gutfilen, B
    da Fonseca, LMB
    JOURNAL OF EXPERIMENTAL & CLINICAL CANCER RESEARCH, 2001, 20 (03) : 385 - 391
  • [5] Comparison of Tc-99m MIBI and Tc-99m tetrofosmin scintigraphies in evaluation of benign and malignant pulmonary lesions
    Tore, G
    Varoglu, E
    Gorguner, M
    LUNG CANCER, 2005, 49 : S217 - S217
  • [6] In vitro prediction of MDR and MRP:: Comparison of Tc-99m MIBI and Tc-99m tetrofosmin
    Fukumoto, M
    Yoshida, D
    Akagi, N
    Kurohara, A
    Murata, Y
    Yoshida, S
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 216P - 216P
  • [7] Scintimammography using Tc-99m tetrofosmin
    Lind, P
    Umschaden, HW
    Forsthuber, E
    Oman, J
    Kerschbaumer, K
    Gallowitsch, HJ
    Mikosch, P
    Kresnik, E
    Molnar, M
    Gomez, I
    ACTA MEDICA AUSTRIACA, 1997, 24 (02) : 50 - 54
  • [8] The comparison of dual phase Tc-99m MIBI and Tc-99m MDP scintimammography in the evaluation of breast masses: Preliminary report
    Arslan, N
    Ozturk, E
    Ilgan, S
    Narin, Y
    Dundar, S
    Tufan, T
    Pekcan, M
    Bayhan, H
    ANNALS OF NUCLEAR MEDICINE, 2000, 14 (01) : 39 - 46
  • [9] The comparison of dual phase Tc-99m MIBI and Tc-99m MDP scintimammography in the evaluation of breast masses: Preliminary report
    Nuri Arslan
    Emel Ozturk
    Seyfettin Ilgan
    Yavuz Narin
    Sabri Dundar
    Turgut Tufan
    Mesut Pekcan
    Hikmet Bayhan
    Annals of Nuclear Medicine, 2000, 14 : 39 - 46
  • [10] Comparative evaluation of Tc-99m MIBI and Tc-99m HMDP scintimammography for diagnosis of breast cancer and axillary lesions
    Nishiyama, Y
    Yamamoto, Y
    Ono, Y
    Satoh, K
    Ohkawa, M
    Tanabe, M
    RADIOLOGY, 1999, 213P : 333 - 333