An Amperometric Hydrogen Peroxide Biosensor Based on Myoglobin Immobilized on SDS-GNPs-GR Modified Electrode

被引:0
作者
Xu, Miao-Qing [1 ]
Wu, Jian-Feng [1 ]
Zhao, Guang-Chao [1 ]
机构
[1] Anhui Normal Univ, Sch Environm Sci, Wuhu 241000, Peoples R China
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2013年 / 8卷 / 05期
基金
中国国家自然科学基金;
关键词
Myoglobin; Graphene; Gold nanoparticles; Biosensor; DIRECT ELECTROCHEMISTRY; GOLD NANOPARTICLES; COMPOSITE FILM; GRAPHENE OXIDE; CYTOCHROME-C; ELECTROCATALYSIS; NANOCOMPOSITES; SHEETS; FABRICATION;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Chemically reduced graphene and gold nanoparticles composites were obtained using sodium dodecyl sulfate (SDS) as stabilizing agent and successfully dispersed fully in water to form a stable black aqueous solution. The as-prepared graphene and gold nanoparticles composites were successfully immobilized on electrode surface to construct a SDS-GNPs-GR modified electrode. The composites showed an obvious promotion of the direct electron transfer between myoglobin (Mb) and the underlying electrode. The experimental results also clarified that the adsorbed Mb retained its biological activity toward the reduction of hydrogen peroxide with high sensitivity and fast response. The biosensor possesses a linear response range of 0.45-8.1 mu M H2O2 with a correlation coefficient of 0.9989 and a detection limit of 1.2x10(-8) M based on a signal-to-noise ratio of 3.
引用
收藏
页码:6502 / 6512
页数:11
相关论文
共 50 条
  • [31] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    Noor, An'amt Mohamed
    Shahid, Muhammad Mehmood
    Rameshkumar, Perumal
    Huang, Nay Ming
    MICROCHIMICA ACTA, 2016, 183 (02) : 911 - 916
  • [32] A hydrogen peroxide sensor based on the peroxidase activity of hemoglobin immobilized on gold nanoparticles-modified ITO electrode
    Zhang, JD
    Oyama, M
    ELECTROCHIMICA ACTA, 2004, 50 (01) : 85 - 90
  • [33] Amperometric biosensor for hydrogen peroxide and nitrite based on hemoglobin immobilized on one-dimensional gold nanoparticle
    Hong, Jianmin
    Dai, Zhihui
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (01): : 222 - 226
  • [34] Hydrogen Peroxide Biosensor Based on Cellulose Diacetate-Ionic Liquid Film Immobilizing Myoglobin
    Dong She-Ying
    Gu Guang-Zhe
    Yu Zhu-Qing
    Zhou Yuan-Zhen
    Tang Hong-Sheng
    Zheng Jian-Bin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (09) : 1358 - 1362
  • [35] MWCNT-cysteamine-Nafion modified gold electrode based on myoglobin for determination of hydrogen peroxide and nitrite
    Canbay, Erhan
    Sahin, Berika
    Kiran, Muge
    Akyilmaz, Erol
    BIOELECTROCHEMISTRY, 2015, 101 : 126 - 131
  • [36] Amperometric Hydrogen Peroxide Biosensor Based on Multiwall Carbon Nanotubes and Cadmium Sulfide Quantum Dots
    Zhang Jin-lei
    Tan Xue-cai
    Zhao Dan-dan
    Tan Sheng-wei
    Huang Zeng-wei
    Mi Yan
    Huang Zai-yin
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2010, 26 (04) : 541 - 545
  • [37] Hydrogen Peroxide Biosensor Based on Immobilization of Hemoglobin on Au@Ag Nanoparticles Modified Carbon Ionic Liquid Electrode
    Xia, Fa-Feng
    Xiao, Guo-Rong
    Ma, Chun-Yang
    Ma, Chun-Hua
    Chu, Dian-Qing
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2013, 60 (04) : 359 - 365
  • [38] Hydrogen peroxide biosensor based on the immobilization of horseradish peroxidase on γ-Al2O3 nanoparticles/chitosan film-modified electrode
    Liu, Xiaojuan
    Luo, Liqiang
    Ding, Yaping
    Xu, Yanhong
    Li, Fei
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2011, 15 (03) : 447 - 453
  • [39] Amperometric Glucose Biosensor Based on Titanium Electrode Modified with Prussian Blue Layer and Immobilized Glucose Oxidase
    Valiuniene, A.
    Virbickas, P.
    Rekertaite, A.
    Ramanavicius, A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (14) : B781 - B784
  • [40] Amperometric and Impedimetric H2O2 Biosensor Based on Horseradish Peroxidase Covalently Immobilized at Ruthenium Oxide Nanoparticles Modified Electrode
    Periasamy, Arun Prakash
    Ting, Shan Wei
    Chen, Shen-Ming
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (07): : 2688 - 2709